We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Suture PGCL (Polyglecaprone 25 / Caprolactone) Prime | ½ Circle Cylindrical Body Taperpoint Conical Point Needle HR30 30 mm | USP 0 Gauge | Violet Thread 75 cm | Box of 12 units | Ref. P312HR3010

44,24 €

Absorbable monofilament suture of polyglecaprone 25 (PGCL / caprolactone) in Prime quality, factory reference P312HR3010 (SKU AMP312HR3010). Mounted on an atraumatic ½ circle needle, cylindrical body and 30 mm Taperpoint conical point (HR30 Prime profile), USP 0 gauge and 75 cm violet thread with high visibility in the surgical field. Predictable absorption by hydrolysis in 90–120 days, with tensile strength retention of 60% at the first week and 30% at the second: smooth passage without cutting effect, minimal tissue reaction and excellent knot security. Indicated for soft tissue approximation and ligatures in general surgery, gynaecology, urology and obstetrics. Sterile by ethylene oxide, single-use and non-reesterilizable. B2B presentation in a box of 12 sterile units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP312HR3010

Description

1. Commercial Introduction

At Cahnos we make available to operating theatres, general surgery services, gynaecology units, urology, obstetrics and purchasing centres the absorbable monofilament suture of polyglecaprone 25 (PGCL, caprolactone) from the Prime range, factory reference P312HR3010 (SKU AMP312HR3010). This presentation combines a ½ circle needle with cylindrical body and Taperpoint conical tip of 30 mm (HR30), USP 0 gauge and violet thread of 75 cm.

It is a medium absorption thread (90–120 days), with exceptional handling, high knot security and a very smooth tissue passage, designed for the professional who needs reliable wound support during the first weeks with a very competitive cost-performance ratio for hospital procurement. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.

2. Technical Explanation

Polyglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) of monofilament structure that degrades by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. Being a monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, maintaining high tensile strength and reliable knot security during the critical phases of healing.

The ½ circle needle with cylindrical body and Taperpoint conical tip passes through soft tissues separating the fibres without cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and soft tissue approximation. The USP 0 gauge (metric 3.5) provides an excellent balance between strength and manageability, and the violet colour guarantees optimal visibility of the thread on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow resterilisation.

3. Technical Specifications

3.1. Technical data sheet of reference AMP312HR3010

Parameter Specification
Reference (SKU Cahnos) AMP312HR3010
Factory reference P312HR3010 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL PRIME)
Range / Quality Prime (premium range)
Material Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament
Thread structure Monofilament
Gauge USP 0 (metric 3.5), conforming to USP/EP Pharmacopoeia
Thread colour Violet (high visibility)
Thread length 75 cm (1 thread · 1 needle per unit)
Needle shape ½ circle (half circumference)
Needle body and point Cylindrical body, Taperpoint conical tip, atraumatic
Needle size HR30 – 30 mm
Absorption mechanism Hydrolysis
Absorption period 90–120 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Soft tissue approximation and general ligatures
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
1 week 60 % of initial strength
2 weeks 30 % of initial strength
Complete absorption 90–120 days, by hydrolysis

Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot security and a totally predictable absorption rate. Price per box of 12 units.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)

USP size Metric measurement (EP) Approximate diameter
0 (this product) 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2/0 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm

4. Equivalences and Cross-References

Polyglecaprone 25 is the polymer used in the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech), clinical reference of the category of synthetic absorbable monofilament of medium absorption, together with homologous families from Assut Medical, DemeTECH (DemeCAPRONE), SMI and other houses. For this specific configuration (PGCL monofilament, USP 0 gauge, ½ circle needle with conical tip of 30 mm and violet thread) the following correspondence has been verified against the manufacturer’s official catalogue and regulatory database (GUDID), with the caveat that the commercial assembly of each house presents differences in needle code and presentation, so they are not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) MONOCRYL® (polyglecaprone 25) violet monofilament, USP 0, 70 cm, SH needle 26 mm, ½ circle, conical tip (taper point) Y318H Comparable by category (not interchangeable 1:1) Confirmed in GUDID (Ethicon LLC, MONOCRYL, violet monofilament of polyglecaprone 25) and authorised distribution: they match material (polyglecaprone 25), USP 0 gauge, violet colour, monofilament structure, ½ circle geometry and conical tip family. They differ in needle size (SH 26 mm vs HR30 30 mm), thread length (70 cm vs 75 cm) and commercial presentation (box of 36 units Ethicon vs 12 units). Validate in technical data sheet/IFU before substituting in tender.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with Taperpoint conical tip (HR30 Prime), USP 0 gauge, violet thread and 75 cm; consult with the technical department before using in tender. The factory reference PREMISUT of this item does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in specifications. As homologous market families to verify in their official data sheet before a substitution, MONOCRYL® / MONOCRYL® Plus from Ethicon (polyglecaprone 25), Monosyn from B. Braun (glyconate) and medium absorption monofilaments from other suppliers (DemeTECH, Assut, SMI) are cited, checking one by one: exact material, USP gauge, ½ circle curvature, needle size of 30 mm, conical tip family, thread length, colour, strength retention and current CE/MDR classification. The brands cited belong to their respective manufacturers and are mentioned only for comparative reference.

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) with 30 mm needle is very versatile: it is indicated for subcutaneous tissue, superficial fascia, soft tissue approximation and ligation of fine-to-medium calibre vessels, with reliable wound support during the first 2–3 weeks. The ½ circle 30 mm needle with Taperpoint conical tip is the most atraumatic option for delicate tissues and medium access spaces; if greater penetration into firm or slightly fibrous tissues is required, consider the trocar point versions (Tapercut / Ultra Plus) from the same family.

Reference Recommended variant
AMP312HR3010 PGCL Prime, HR 30 mm needle Taperpoint conical tip, USP 0, violet, 75 cm (analysed product)
AMP312HR3010.2 PGCL Prime, HR 30 mm needle Taperpoint conical tip, USP 0, violet, double thread 2×75 cm (double armed)
AMP312HR3001 PGCL Prime, HR 30 mm needle conical tip, USP 1, violet, 75 cm (larger gauge)
AMP312HR3001.2 PGCL Prime, HR 30 mm needle conical tip, USP 1, violet, 2×75 cm (higher strength)
AMP312HR3030.2 PGCL Prime, HR 30 mm needle conical tip, USP 3/0, violet, 2×75 cm (finer gauge)
AMP312HR2620 PGCL Prime, HR 26 mm taper point needle, USP 2/0, violet, 75 cm (shorter needle)

All references are supplied in boxes of 12 units. If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is required, consider PGA (60–90 days) or polyglactin 910 (56–72 days). As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure and store the suture in a cool, dry place below 30 °C, protected from direct sunlight. For special B2B volume conditions, hospital supply contracts or validation of equivalence with other commercial brands, contact our technical-commercial team.

Additional information

Material

Poliglecaprone 25 (PGCL / caprolactone)

Gauge

USP 0 (metric 3.5)

Thread length

75 cm (1 suture · 1 needle)

Needle type

Cylindrical body, conical Taperpoint tip

Needle size

HR30 – 30 mm

Absorption mechanism

Hydrolysis

Strength retention

60% at 1 week / 30% at 2 weeks

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Manufacturer reference

P312HR3010

Product line

Prime (premium)

Medida de aguja

HR 30

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Monofilament

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Suture PGCL (Polyglecaprone 25 / Caprolactone) Prime | ½ Circle Cylindrical Body Taperpoint Conical Point Needle HR30 30 mm | USP 0 Gauge | Violet Thread 75 cm | Box of 12 units | Ref. P312HR3010”

Your email address will not be published. Required fields are marked *