Description
1. Commercial Introduction
At Cahnos we make available to operating theatres, general surgery departments, gynaecology and obstetrics units and purchasing centres the absorbable monofilament suture of polyglecaprone 25 (PGCL / caprolactone) from the Prime range, factory reference P313HR2240-2VB (SKU AMP313HR2240-2VB). This presentation combines a double-needle configuration of ½ circle with cylindrical body and 22 mm Taperpoint conical point (2×HR22) in a maximum-contrast VisiBlack finish, USP 4/0 gauge and 90 cm violet thread: a fine configuration, highly precise and with very smooth passage through tissue, designed for the approximation of delicate soft tissues and ligation of small-calibre vessels.
It is a medium-absorption thread (90–120 days), with exceptional handling, high knot security and a very competitive quality-performance ratio for B2B hospital supply. Synthetic absorbable, sterile, single-use medical device, supplied in a box of 12 units.
2. Technical Explanation
Polyglecaprone 25 (PGCL) is a synthetic copolymer of glycolide and ε-caprolactone that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity, ensuring predictable absorption between 90 and 120 days and minimal tissue reaction. As it is a non-channeled monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence compared with braided multifilament sutures, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The double-needle configuration (2×HR22) allows the suture to be started from both ends without rethreading, speeding up continuous closures and sutures in deep planes. The ½-circle needle with cylindrical body and 22 mm Taperpoint conical point passes through soft tissues by separating the fibres without cutting effect, making it especially atraumatic in delicate structures and subcutaneous tissue. The VisiBlack finish of the needle, together with the violet thread, ensures optimal visibility over the surgical field even with difficult lighting or bleeding. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference P313HR2240-2VB (SKU AMP313HR2240-2VB)
| Parameter | Specification |
| Reference Cahnos (SKU) | AMP313HR2240-2VB |
| Factory reference | P313HR2240-2VB (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL PRIME) |
| Range / Quality | Prime (premium range) |
| Material | Polyglecaprone 25 (PGCL / caprolactone), copolymer of glycolide and ε-caprolactone, synthetic absorbable |
| Thread structure | Monofilament, non-grooved (smooth surface) |
| Gauge / Size | USP 4/0 (EP metric 1.5), in accordance with USP Pharmacopoeia and European Pharmacopoeia |
| Thread diameter | 0.15 – 0.199 mm |
| Thread colour | Violet (high visibility in the field) |
| Thread length | 90 cm |
| Swaged | Double needle (2×HR22): needle at both ends of the thread |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, Taperpoint conical tip, atraumatic, VisiBlack finish |
| Needle size | HR22 – 22 mm each needle (2×HR22 VisiBlack Prime) |
| Absorption mechanism | Complete hydrolysis (without enzymatic activity) |
| Absorption time | 90 – 120 days |
| Tensile strength retention | ≈ 60 % at 1 week · ≈ 30 % at 2 weeks |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and continuous suturing; general surgery, gynaecology and obstetrics |
| Presentation | Box of 12 units (individual sterile sachets) |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a fully predictable absorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
4. Equivalences and Cross-References
Polyglecaprone 25 monofilament is one of the most well-established families of synthetic absorbable sutures with medium absorption on the market, with Ethicon’s MONOCRYL® line (Johnson & Johnson MedTech) being the clinical reference in the category. For the USP 4/0 configuration, violet thread, ½-circle 22 mm taper-point needle and long strand, the following correspondence has been verified against the manufacturer’s official catalogue (Ethicon EPC) and authorised distribution; as these are configurations from another manufacturer and with a single needle compared with the double needle-to-needle configuration of this reference, it is not declared 1:1 interchangeable:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | MONOCRYL® (polyglecaprone 25) monofilament, violet, USP 4/0, 70 cm, 22 mm SH-1 PLUS needle, ½ circle, Taperpoint conical point | Y218H | Comparable by category (not interchangeable 1:1) | Verified against the official Ethicon catalogue (EPC) and authorised distribution: material (polyglecaprone 25), USP 4/0 gauge, violet colour, monofilament structure, ½-circle curvature, 22 mm needle size and Taperpoint conical point family all match. The configuration differs (single SH-1 PLUS needle vs. double 2×HR22 VisiBlack Prime needle), thread length (70 cm vs. 90 cm) and commercial presentation (box of 36 units vs. 12). Validate in the technical data sheet/IFU before substituting in a tender. |
There is no manufacturer-validated equivalence table cross-referencing this specific reference (PGCL monofilament, double ½-circle HR22 needle with 22 mm VisiBlack conical point, USP 4/0 gauge and 90 cm violet thread, ref. P313HR2240-2VB) with references from other manufacturers in an exact needle-to-needle configuration; consult the technical department before using in a tender or direct substitution. The factory reference PREMISUT does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in tender specifications. As homologous families in the sector to be verified in their official data sheet before substitution, the following are cited: MONOCRYL® / MONOCRYL® Plus Antibacterial from Ethicon (polyglecaprone 25, the latter with triclosan, a relevant functional difference), Monosyn from B. Braun (glyconate), Biosyn and Caprosyn from Medtronic (glycomer) and medium-absorption monofilaments from other suppliers (DemeTECH – DemeCAPRONE –, SMI Surgicryl, Assut), checking one by one: exact material, USP 4/0 gauge, configuration (number of needles), ½-circle curvature, 22 mm needle size, conical point family, thread length, colour and current CE/MDR regulatory classification. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
The USP 4/0 gauge (metric 1.5) with a 22 mm needle is a fine, high-precision thread: it is indicated for thin skin, subcutaneous tissue, mucosa, approximation of delicate soft tissues and ligation of small-calibre vessels, with reliable wound healing support during the first 2–3 weeks. The double needle-needle configuration facilitates continuous sutures and bidirectional approximation without rethreading; if the protocol prefers interrupted sutures, the family offers single-needle versions. The ½ circle needle with Taperpoint conical point is the most atraumatic option for soft tissues; if working with somewhat more fibrous tissues, consider the trocar point versions (Tapercut / Ultra Plus) from the same range. The VisiBlack finish is especially indicated when maximum needle contrast is required in deep or bleeding fields.
| Reference (SKU) | Variant of interest |
| AMP313HR2240-2VB | PGCL Prime VisiBlack, double needle HR22, USP 4/0, violet, 90 cm (product analysed) |
| AMP318HR2240-2VB | PGCL Prime VisiBlack, double needle HR22, USP 4/0, violet, 70 cm (shorter thread) |
| AMP313HR2630-2VB | PGCL Prime VisiBlack, double needle HR26, USP 3/0, violet, 90 cm (larger gauge and larger needle radius) |
| AMP318HR2230-2VB | PGCL Prime VisiBlack, double needle HR22, USP 3/0, violet, 70 cm (thicker gauge, same needle) |
| AMP312HR2240 | PGCL Prime, single needle HR22 conical point, USP 4/0, violet, 75 cm (single needle configuration) |
| AMP413HR2630-2VB | PDO (polydioxanone) Prime VisiBlack, double needle HR26, USP 3/0, violet, 90 cm (absorption 180–210 days, prolonged support) |
All references are supplied in boxes of 12 units. If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days). As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure, store the suture in a cool, dry place below 30 °C, protected from direct sunlight, and handle the strand with gloves to avoid altering its mechanical properties. For special B2B conditions by volume, hospital supply contracts or validation of equivalence with other commercial brands, contact our technical-commercial team at Cahnos.





Reviews