Description
1. Commercial Introduction
At Cahnos we offer operating theatres, general surgery services, gynaecology, obstetrics, urology units and procurement centres the absorbable monofilament polyglecaprone 25 (PGCL, caprolactone) suture from the Prime range, reference SKU AMP313HR2630-2VB. This presentation combines a double needle of ½ circle 26 mm (2×HR26) assembly with a cylindrical body and Taperpoint conical tip with a VisiBlack high-contrast finish, USP 3/0 gauge and violet thread of 90 cm.
This is a medium-absorption thread (90–120 days), with exceptional handling, high knot security and very smooth tissue passage, designed for the professional who requires reliable wound support during the first weeks with a very competitive cost-performance ratio for B2B hospital procurement. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical Explanation
Polyglecaprone 25 (PGCL) is a synthetic copolymer of glycolide and ε-caprolactone that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity, ensuring predictable absorption between 90 and 120 days and minimal tissue reaction. Being a monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence compared to braided multifilaments, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The double needle assembly allows starting the suture from both ends without rethreading, which speeds up continuous closures and sutures in deep planes. The ½ circle needle with cylindrical body and 26 mm Taperpoint conical tip penetrates soft tissues by separating fibres without cutting effect, being especially atraumatic in delicate structures and subcutaneous tissue. The VisiBlack finish of the needle, together with the violet thread, ensures optimal visibility on the surgical field even with difficult lighting or bleeding. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP313HR2630-2VB
| Parameter | Specification |
| Reference Cahnos (SKU) | AMP313HR2630-2VB |
| Material | Polyglecaprone 25 (PGCL / caprolactone), copolymer of glycolide and ε-caprolactone, synthetic absorbable |
| Thread structure | Synthetic absorbable monofilament |
| Quality / Range | Prime (premium range) |
| Gauge / Size | USP 3/0 (metric EP 2), conforming to USP and European Pharmacopoeia |
| Thread diameter | 0.20 – 0.249 mm |
| Thread colour | Violet (high visibility in the field) |
| Thread length | 90 cm |
| Swaged | Double needle (2×HR26): needle at both ends of the thread |
| Needle shape | ½ circle (1/2 circular) |
| Needle body and point | Cylindrical body, Taperpoint conical tip, atraumatic, VisiBlack finish |
| Needle size | HR26 – 26 mm each needle (2×HR26 VisiBlack prime) |
| Absorption mechanism | Complete hydrolysis (without enzymatic activity) |
| Absorption time | 90 – 120 days |
| Tensile strength retention | ≈ 60 % at 1 week · ≈ 30 % at 2 weeks |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and continuous suture; general surgery, gynaecology, obstetrics and urology |
| Presentation | Box of 12 units (individual sterile sachets) |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a fully predictable absorption rate. Price per box of 12 units.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Polyglecaprone 25 monofilament is one of the most established families of synthetic absorbable medium-absorption sutures on the market, with the MONOCRYL® line from Ethicon (Johnson \u0026 Johnson MedTech) being the clinical reference in the category. For the USP 3/0 configuration, violet thread, ½ circle 26 mm conical tip needle, the following correspondences have been checked against the manufacturer’s official catalogue (Ethicon EPC) and authorised distribution; since these are assemblies from another manufacturer and with a single needle compared to the double needle-to-needle assembly of this reference, they are not declared 1:1 interchangeable:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | MONOCRYL® (polyglecaprone 25) monofilament, violet, USP 3/0, 70 cm, SH conical tip needle, ½ circle | Y316H | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: material (polyglecaprone 25), gauge USP 3/0, colour violet, monofilament structure, ½ circle geometry, 26 mm conical needle and absorption profile match. They differ in thread length (70 cm vs 90 cm), assembly (single SH needle vs double 2×HR26 VisiBlack needle) and commercial presentation (box of 36 units vs 12). Validate in technical data sheet/IFU before substituting in tender. |
| Ethicon (J&J MedTech) | MONOCRYL® Plus Antibacterial (polyglecaprone 25 with triclosan), violet, USP 3/0, 70 cm, SH conical tip needle | MCP316H | Comparable by category (not interchangeable 1:1) | Same basic configuration as Y316H and as this reference in material, gauge, needle and tip family; it differs in the antibacterial triclosan coating (not present in this product), thread length and double needle assembly. Confirmed in Ethicon EPC catalogue and authorised distribution. |
There is no equivalence table validated by the manufacturer that cross-references this specific reference (PGCL monofilament, double needle half circle HR26 of 26 mm taper point VisiBlack, USP 3/0 gauge and violet thread of 90 cm, ref. AMP313HR2630-2VB) with references from other manufacturers in exact needle-to-needle configuration; consult the technical department before use in tenders or direct substitution. The factory reference for this item does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in specifications. As homologous families in the sector to verify on their official datasheet before substitution, the following are cited: MONOCRYL® / MONOCRYL® Plus Antibacterial from Ethicon (poliglecaprone 25 with triclosan), Monosyn from B. Braun (gliconate), Biosyn and Caprosyn from Medtronic (glycomer) and medium-absorption monofilaments from other suppliers (DemeTECH – DemeCAPRONE –, SMI Surgicryl, Assut), checking one by one: exact material, USP 3/0 gauge, configuration (number of needles), half circle curvature, needle size of 26 mm, taper point family, length and number of strands, colour and current CE/MDR regulatory classification. The brands cited belong to their respective manufacturers and are mentioned solely for comparative reference.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) with a 26 mm needle is the most versatile combination in the catalogue: it is indicated for skin, subcutaneous tissue, mucosa, superficial fascia, muscle and ligation of fine-to-medium calibre vessels, with reliable wound support during the first 2–3 weeks. The double needle-to-needle configuration facilitates continuous sutures and bidirectional approximation without rethreading; if the protocol prefers interrupted sutures, the family offers single-needle versions. The half circle taper point Taperpoint needle is the most atraumatic option for soft tissues; if greater penetration is required in firm or slightly fibrous tissues, consider the trocar point versions from the same range. The VisiBlack finish is especially indicated when maximum needle contrast is required in deep or bleeding fields.
| Reference (SKU) | Variant of interest |
| AMP313HR2630-2VB | PGCL Prime VisiBlack, double needle HR26 of maximum contrast, USP 3/0, violet, 90 cm (product analysed) |
| AMP318HR2630-2VB | PGCL Prime VisiBlack, double needle HR26, USP 3/0, violet, 70 cm (shorter thread) |
| AMP318HR2230-2VB | PGCL Prime VisiBlack, double needle HR22, USP 3/0, violet, 70 cm (smaller radius needle) |
| AMP313HR2620 | PGCL Prime, single needle HR26 taper point, USP 2/0, violet, 90 cm (larger gauge, single needle) |
| AMP313HRP2620 | PGCL Prime, single needle HRP26 taper point Ultra Plus, USP 2/0, violet, 90 cm (precision point) |
| AMP312HR2620.2 | PGCL Prime, double thread 2×75 cm, needle HR26 taper point, USP 2/0, violet (double thread configuration) |
All references are supplied in boxes of 12 units. If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is required, consider PGA (60–90 days) or polyglactin 910 (56–72 days). As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure, store the suture in a cool, dry place below 30 °C, protected from direct sunlight, and handle the thread with gloves to avoid altering its mechanical properties. For special B2B conditions by volume, hospital supply contracts or validation of equivalence with other commercial brands, contact our technical-commercial team at Cahnos.





Reviews