Description
1. Commercial Introduction
The absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone) from the Prime range is the technical choice when the procedure requires controlled absorption, minimal inflammatory response and especially smooth passage of the thread through tissue. This presentation, manufacturer reference P328HR1730 (SKU AMP328HR1730), combines a ½ circle needle with cylindrical body and taper point of 17 mm (HR17), USP 3/0 gauge and 70 cm colourless thread: a very versatile and cost-effective configuration for approximation of soft tissues and ligatures in general surgery, gynaecology, urology and paediatric surgery.
It is a medium absorption thread (90–120 days), with exceptional handling and high knot security, designed for the professional who needs reliable wound healing support during the first weeks, with a very competitive quality-price ratio for hospital supply and purchasing centres. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units. The colourless colour of the thread is recommended when maximum aesthetic discretion is sought in subcutaneous and intradermal planes.
2. Technical explanation
Poliglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) with a monofilament structure that degrades by hydrolysis, that is, by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. Being a non-grooved monofilament, the strand presents a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of healing.
The ½ circle needle with cylindrical body and taper point passes through soft tissues separating the fibres without cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and approximation of soft tissues. The USP 3/0 gauge (metric 2) provides an excellent balance between manageability and initial resistance. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP328HR1730
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP328HR1730 |
| Factory reference | P328HR1730 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL PRIME) |
| Range / Quality | Prime (premium range) |
| Material | Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Colourless |
| Thread length | 70 cm (1 thread · 1 needle per unit) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, conical Taperpoint tip |
| Needle size | HR17 – 17 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90–120 days |
| Tensile strength | 1 week: 60 %; 2 weeks: 30 % |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Soft tissue approximation and general ligatures |
| Presentation | Box of 12 sterile units · minimum order 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 1 week | 60 % of initial strength |
| 2 weeks | 30 % of initial strength |
| Complete absorption | 90–120 days, by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Poliglecaprone 25 monofilament is one of the most well-established families of synthetic absorbable sutures of medium absorption on the market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference of the category. For the USP 3/0 configuration, ½ circle taper point needle of 17 mm and 70 cm strand in colourless, the following correspondences have been verified against manufacturer sources and authorised distribution, with the caveat that the commercial assembly of each house presents differences in point finish and presentation, so they are not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, colourless, USP 3/0, 70 cm, RB-1 needle of 17 mm, ½ circle, taper point | Y215H | Comparable by category (not interchangeable 1:1) | Confirmed in official Ethicon data sheet (EPC) and authorised distribution: they match in material (poliglecaprone 25), USP 3/0 gauge, thread length (70 cm), colourless colour, ½ circle shape and needle size (17 mm) with taper point; they differ in point finish (conventional RB-1 taper point versus HR17 Taperpoint) and commercial presentation (Ethicon boxes of 36 units versus 12 units). Validate in the technical data sheet before substituting in a tender. |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, violet, USP 3/0, 70 cm, RB-1 needle of 17 mm, ½ circle, taper point | Y305H | Comparable by category (not interchangeable 1:1) | Confirmed in official Ethicon data sheet (EPC) and authorised distribution: same base configuration (3/0 · 70 cm · RB-1 needle of 17 mm, ½ circle, taper point) in violet version versus the colourless thread of this reference; they differ in colour and point finish, as well as presentation. Verify in the technical data sheet before substituting. |
There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with taper point (HR17 Prime), USP 3/0 gauge, colourless thread and 70 cm; consult the technical department before using in a tender. As homologous families on the market to verify in their official data sheet before substitution, the MONOCRYL® line from Ethicon (poliglecaprone 25), the MONOCRYL® Plus Antibacterial version (triclosan load, relevant functional difference) and medium absorption absorbable monofilaments of the poliglecaprone 25 type from other suppliers (B. Braun Monosyn based on gluconate, Medtronic Biosyn/Caprosyn, DemeTECH, SMI, Assut) are cited, checking reference by reference the USP 3/0 gauge, the 17 mm needle size in ½ circle, the taper point, the 70 cm thread length and the colourless colour.
5. Selection tips and variants of interest
The USP 3/0 gauge offers an optimal balance between strength and fineness: it is indicated for skin, subcutaneous tissue, mucosa, fascia, muscle and ligation of medium-fine vessels. The colourless thread is the option of maximum aesthetic discretion in subcutaneous and intradermal planes; if optimal visibility over the surgical field is preferred, consider the violet version of the same configuration. The ½ circle 17 mm needle with taper point is the most atraumatic option for delicate tissues and confined spaces; if greater penetration into firm or slightly fibrous tissues is required, consider the trocar point versions (Tapercut / Ultra Plus) of the same family.
| Reference | Recommended variant |
| AMP328HR1730 | PGCL Prime, HR 17 mm taper point Taperpoint needle, USP 3/0, colourless, 70 cm (product analysed) |
| AM328HR1730 | PGCL Normal quality, HR 17 mm taper point Taperpoint needle, USP 3/0, colourless, 70 cm (same configuration, standard range) |
| AMP318HR1730 | PGCL Prime, HR 17 mm taper point Taperpoint needle, USP 3/0, violet, 70 cm (high visibility) |
| AMP318HRP1730 | PGCL Prime, HRP 17 mm Ultra Plus taper point (trocar) needle, USP 3/0, violet, 70 cm (greater penetration) |
| AMP328HRP1730 | PGCL Prime, HRP 17 mm Ultra Plus taper point needle, USP 3/0, violet, 70 cm (factory reference P328) |
| AMP318HR1740 | PGCL Prime, HR 17 mm taper point Taperpoint needle, USP 4/0, violet, 70 cm (greater precision) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences with other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.