Description
1. Product Presentation
At Cahnos we make available to operating theatres, general surgery departments, gynaecology units, urology and purchasing centres the absorbable monofilament suture of poliglecaprone 25 (PGCL, caprolactone) from the Prime range, factory reference P318HR1730 (SKU AM318HR1730). This presentation combines a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 3/0 gauge and violet thread of 70 cm: a very versatile and cost-effective configuration for the approximation of soft tissues and ligatures in general surgery, gynaecology, urology and paediatric surgery.
It is a medium absorption thread (90–120 days), with exceptional handling, high knot security and a very smooth passage through tissue, designed for the professional who needs reliable wound support during the first weeks, with a very competitive quality-performance ratio for hospital supply. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.
2. Technical explanation
Poliglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) with a monofilament structure that degrades by hydrolysis, i.e., by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. Being a non-grooved monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The ½ circle needle with cylindrical body and Taperpoint conical point passes through soft tissues by separating the fibres without a cutting effect, making it especially atraumatic in delicate structures, subcutaneous tissue and approximation of soft tissues. The USP 3/0 gauge (metric 2) provides an excellent balance between manageability and initial strength, and the violet colour of the thread guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM318HR1730
| Parameter | Specification |
| Reference (SKU Cahnos) | AM318HR1730 |
| Factory reference | P318HR1730 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL) |
| Range / Quality | Prime (premium range) |
| Material | Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament |
| Thread structure | Monofilament, non-channeled |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet (high visibility) |
| Thread length | 70 cm (1 thread · 1 needle per unit) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical body, Taperpoint conical tip, atraumatic |
| Needle size | HR17 – 17 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90–120 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, general surgery, gynaecology, urology and paediatric surgery |
| Presentation | Box of 12 sterile units · minimum order 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 1 week | 60 % of initial strength |
| 2 weeks | 30 % of initial strength |
| Complete absorption | 90–120 days, by hydrolysis |
Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot tying and a fully predictable absorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Poliglecaprone 25 monofilament is one of the most well-established medium absorption synthetic absorbable suture materials on the market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference in the category. For the USP 3/0 configuration, ½ circle needle with conical point of 17 mm and 70 cm violet strand, the following correspondence has been verified against the manufacturer’s official catalogue (Ethicon EPC) and authorised distribution, with the caveat that the commercial assembly of each house presents differences in point finish and presentation, so they are not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® – poliglecaprone 25 monofilament, violet, USP 3/0, 70 cm, RB-1 needle of 17 mm, ½ circle, conical point (taper point) | Y305H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon catalogue (EPC) and authorised distribution: material (poliglecaprone 25), USP 3/0 gauge, thread length (70 cm), violet colour, ½ circle shape and needle size (17 mm) with conical point all match. The point finish (conventional RB-1 taper point versus HR17 Taperpoint Prime) and the commercial presentation (box of 36 units Ethicon versus 12 units) differ. Validate in the technical data sheet/IFU before substituting in a tender. |
There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with Taperpoint conical point (HR17 Prime), USP 3/0 gauge, violet thread and 70 cm; consult the technical department before using in a tender. The factory reference PREMISUT of this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before its use in specifications. As homologous market families to verify in their official data sheet before a substitution, the MONOCRYL® and MONOCRYL® Plus Antibacterial lines from Ethicon (poliglecaprone 25), Monosyn from B. Braun (glyconate, different degradation kinetics) and medium absorption absorbable monofilaments from other suppliers (DemeTECH, SMI, Assut) are cited, checking one by one: exact material, USP 3/0 gauge, ½ circle curvature, 17 mm needle size, conical point family, 70 cm thread length, violet colour and CE/MDR regulatory classification. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) with a 17 mm needle offers an optimal balance between strength and fineness: it is indicated for skin, subcutaneous tissue, mucosa, fascia, muscle and ligatures of fine-to-medium calibre vessels, being very useful in paediatric surgery and precision procedures. The violet colour maximises visibility on the surgical field; if maximum aesthetic discretion is preferred in subcutaneous and intradermal planes, consider the colourless version of the same configuration (ref. P328HR1730). The ½ circle conical point needle of 17 mm is the most atraumatic option for delicate tissues and reduced access; if greater penetration is required in firm or slightly fibrous tissues, consider the Ultra Plus precision point versions (HRP) of the same family.
| Reference | Recommended variant |
| AM318HR1730 | PGCL Prime, HR17 needle conical Taperpoint tip, USP 3/0, violet, 70 cm (product analysed) |
| AMP318HRP1730 | PGCL Prime, HRP17 needle Ultra Plus conical point, USP 3/0, violet, 70 cm (greater penetration) |
| AMP328HR1730 | PGCL Prime, HR17 needle conical point, USP 3/0, colourless, 70 cm (aesthetic discretion) |
| AMP318HR1740 | PGCL Prime, HR17 needle conical point, USP 4/0, violet, 70 cm (greater precision) |
| AMP318HR1750 | PGCL Prime, HR17 needle conical point, USP 5/0, violet, 70 cm (paediatrics and fine tissues) |
| AMP318HR2630VB | PGCL Prime VisiBlack, HR26 needle conical point, USP 3/0, violet, 70 cm (larger radius needle and maximum contrast) |
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure and store the suture in a cool, dry place below 30 °C, protected from direct sunlight. For special B2B volume conditions, hospital supply contracts or validation of equivalents with other commercial brands, contact our technical-commercial team.





Reviews
There are no reviews yet.