Description
1. Commercial Introduction
The PGAR RAPID Prime absorbable suture is the fast-absorption reference in the PREMISUT RAPID range for the professional who needs a resorbable thread with predictable handling, high knot security and complete disappearance from the body within a few weeks, without the need for removal. This configuration combines a braided multifilament strand of fast-profile polyglycolic acid in USP 2/0 gauge, colourless and 90 cm long, with a ½ circle needle with cylindrical body and trocar point of 36 mm (HRT36 profile): the ideal combination for approximating tissues of a certain density, ligatures and general surgery.
Sterile product, ready to use, presented in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and tenders seeking a high-performance fast-absorption thread with an excellent price-quality ratio, with the utmost consistency of Prime quality batch after batch.
2. Technical Explanation
The PGAR suture (fast-profile polyglycolic acid) is a synthetic polymer 100% absorbable by hydrolysis, braided into a multifilament and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction. Its degradation profile is designed for short-term healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days.
The HRT36 needle features a ½ circle curvature (1/2 circular, 160°) with a cylindrical body and trocar point (Tapercut): the round body allows clean passage through soft tissues, while the triangular point pierces dense tissue without tearing it, reducing trauma to the puncture bed. Its 36 mm length makes it suitable for muscle planes, aponeuroses, deep subcutaneous tissue and approximation of tissues under moderate tension. The USP 2/0 gauge (metric EP 3) provides an optimal balance between strength and fineness. Sterilisation by gamma radiation; single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | P223HRT3620 (Prime range) |
| Reference Cahnos (SKU) | AMP223HRT3620 |
| Brand / quality | PREMISUT RAPID (Prime range) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament |
| Thread structure | Braided (multifilament), smooth finish |
| Coating | Polycaprolactone and calcium stearate |
| Absorption | Rapid by hydrolysis, completed between 40 and 45 days |
| Tensile strength retention | 50% at 5 days; 0% at 14 days |
| Gauge | USP 2/0 (metric 3 / EP 3), according to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Colourless |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Needle tip | Trocar / Tapercut (triangular) |
| Needle size | HRT 36 Prime (36 mm), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, general surgery and moderate tension planes |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.
3.3. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the fast-absorption formulation (RAPID line); it must not be confused with standard-absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.
3.4. Decoding of the official reference
Official reference P223HRT3620: P (Prime range) + 223 (90 cm thread) + HRT36 (½ circle needle with cylindrical body and 36 mm trocar point) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference P223HRT3620 corresponds to the official nomenclature of the PREMISUT RAPID range (fast-absorption polyglycolic acid, multifilament, USP 2/0, colourless 90 cm thread, ½ circle cylindrical needle with 36 mm Tapercut trocar point). Fast-absorption polyglycolic acid (PGAR) is one of the most widespread braided absorbable suture families on the market and is comparable at a clinical category level with the fast-absorption lines of major manufacturers. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and in authorised distributor sources is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | W9962 (EMEA) | Comparable by category (not interchangeable 1:1) | They match: fast absorption (≈42 days), USP 2/0 gauge, colourless 90 cm thread and ½ circle 36 mm needle with Tapercut point (V-34). They differ: the polymer (polyglactin 910: glycolide/L-lactide versus polyglycolic acid), the braid coating and the packaging format (36 units in Ethicon). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors. |
The remaining homologous lines in the fast-absorption segment (Safil Quick and NOVOSYN QUICK from B. Braun, DemeCRYL Fast from DemeTECH, Surgicryl Fast Absorb from SMI) must be reviewed property by property (material, USP 2/0 gauge, multifilament structure, ½ circle curvature, trocar point family, 36 mm needle length, 90 cm strand length, colourless colour, 1-needle configuration and CE/MDR regulatory classification) before any substitution; they are not included in the table because no verified code is available for this exact combination. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided the gauge and needle geometry are respected.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for tissues under moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small-calibre vessels. The HRT36 half-circle needle with trocar point combines the penetration of a cutting point with the non-traumatic passage of the cylindrical body: it is the recommended option when firm penetration is required without a broad cutting effect, especially in medium-consistency tissues.
| Variant (SKU) | Description |
| AMP223HRT3620 (P223HRT3620) | PGAR RAPID Prime – HRT36 – USP 2/0 undyed – 90 cm (this product) |
| AMP222HRT3620 (P222HRT3620) | PGAR RAPID Prime – HRT36 – USP 2/0 undyed – 75 cm (same geometry, less thread) |
| AMP223HRT3610 (P223HRT3610) | PGAR RAPID Prime – HRT36 – USP 0 undyed – 90 cm (same needle, larger gauge) |
| AMP223HRT4020 (P223HRT4020) | PGAR RAPID Prime – HRT40 – USP 2/0 undyed – 90 cm (40 mm needle) |
| AM223HRT3620 (223HRT3620) | PGAR RAPID standard – HRT36 – USP 2/0 undyed – 90 cm (standard range, without Prime) |
| AMP2L23HRT3620 (P2L23HRT3620) | PGLAR Polyglactin 910 RAPID – HRT36 – USP 2/0 undyed – 90 cm (same geometry, glycolide/L-lactide copolymer) |
If the protocol prefers a conical point for very lax tissues, refer to the cylindrical HR36 family (ref. AMP223HR3620); for tissues where minimal injury is sought, the blunt point HRN36 (ref. AMP223HRN3620). The undyed version offers maximum discretion in the surgical field; if greater visibility is required, consider the same configuration in dyed thread on request. Sterility and storage: product sterilised by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference P223HRT3620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.