We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RAPID Prime · ½ Circle Needle Cylindrical Body Trocar Point (Tapercut) 36 mm HRT36 · USP 0 Colourless 90 cm · Box of 12 units (Ref. P223HRT3610)

Original price was: 45,52 €.Current price is: 34,80 €.

Absorbable multifilament rapid-absorption suture PGAR RAPID Prime (100% polyglactic acid) with a ½-circle needle, cylindrical body and 36 mm trocar point (HRT36 profile): firm penetration in dense tissues without tearing. USP 0 gauge (metric 3.5), colourless thread 90 cm, coating of polycaprolactone and calcium stearate ensuring smooth sliding and secure knot. Predictable absorption by hydrolysis in 40–45 days, with 50% tensile strength retention at 5 days and 0% at 14 days. Sterilised by gamma radiation, single-use. Factory reference P223HRT3610 · SKU Cahnos AMP223HRT3610. Price per box of 12 units; minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP223HRT3610

Description

1. Commercial Introduction

The Absorbable Suture PGAR RAPID Prime is the rapid absorption reference of the PREMISUT RAPID range for the professional who needs a resorbable thread with predictable handling, high knot security and complete disappearance from the body within a few weeks, without the need for removal. This configuration combines a braided multifilament strand of polyglactic acid in USP 0 gauge, undyed and 90 cm long, with a ½ circle needle with cylindrical body and trocar point of 36 mm (HRT36 profile): the ideal combination for approximation of tissues with some density, ligatures and general surgery.

Sterile product, ready to use, presented in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and tenders seeking a high-performance rapid absorption thread with an excellent price-quality ratio, with the maximum consistency of Prime quality batch after batch.

2. Technical Explanation

The PGAR suture (polyglactic acid / polyglycolic acid with rapid profile) is a synthetic polymer 100% absorbable by hydrolysis, braided into multifilament and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm and secure knotting, with minimal tissue reaction. Its degradation profile is designed for short-term healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days.

The HRT36 needle features a ½ circle curvature (1/2 circular) with cylindrical body and trocar point (tapercut): the round body allows clean passage through soft tissues while the triangular point cuts dense tissue without tearing it, reducing trauma to the puncture bed. Its 36 mm length makes it suitable for muscular planes, aponeuroses, subcutaneous tissue and approximation of tissues with moderate tension. The USP 0 gauge (metric EP 3.5) provides the necessary resistance for medium-high tension planes. Sterilisation by gamma radiation; single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference P223HRT3610 (Prime range)
Reference Cahnos (SKU) AMP223HRT3610
Brand / quality PREMISUT RAPID (Prime range)
Thread material 100% polyglactic acid (PGAR), braided multifilament
Thread structure Braided (multifilament), smooth finish
Coating Polycaprolactone and calcium stearate
Absorption Rapid by hydrolysis, completed between 40 and 45 days
Tensile strength retention 50% at 5 days; 0% at 14 days
Gauge / size USP 0 (metric 3.5 / EP 3.5), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.35 – 0.399 mm
Thread length 90 cm (free end, without loop)
Thread colour Colourless
Needle shape ½ circle (1/2 circular)
Tip type Cylindrical body with trocar point (Tapercut)
Needle size HRT 36 Prime (36 mm), 1 needle per thread
Swaged 1 needle / 1 suture per unit
Sterilisation Gamma radiation; sterile, single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures, general surgery and moderate tension planes
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
0 (this product) 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2/0 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm

The diameter of the strand complies with the official ranges of the USP Pharmacopoeia for synthetic absorbable sutures, without extending its limits.

3.3. Decoding of the official reference

Decoding of the official reference P223HRT3610: P (Prime range) + 223 (90 cm thread) + HRT36 (½ circle needle with cylindrical body and trocar point of 36 mm) + 10 (USP 0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

The reference P223HRT3610 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglactic acid, multifilament, USP 0, undyed 90 cm thread, ½ circle cylindrical needle with trocar point of 36 mm). Rapid absorption polyglactic acid (PGAR) is one of the most widespread braided absorbable suture families on the market and can be homologated at clinical category level with the rapid absorption lines of the major manufacturers.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910) undyed VR2218 Comparable by category (not interchangeable 1:1) It matches in USP 0 gauge, 90 cm of undyed thread and ½ circle tapercut needle of 36 mm (V-34); the polymer differs (polyglactin 910: glycolide/L-lactide versus PGA) and the manufacturer.

Homologous families of the segment that must be reviewed property by property (material, USP 0 gauge, multifilament structure, ½ circle curvature, trocar point family, needle length 36 mm, strand length 90 cm, undyed colour, 1 needle assembly and CE/MDR regulatory classification) before any substitution: VICRYL RAPIDE® (Ethicon / J&J MedTech), Safil Quick® (B. Braun / Aesculap) and the rapid PGA ranges of European distribution. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference; no unverified cross-reference codes are published.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) is a medium-high size indicated for planes with moderate tension: tissue approximation, ligatures, closure of deep planes, general surgery and minor surgery. The HRT36 ½-circle needle with trocar point combines the penetration of a cutting point with the atraumatic passage of the cylindrical body: suitable for dense or poorly distensible tissues without enlarging the puncture bed.

Variant (SKU) Description
AMP223HRT3610 (P223HRT3610) PGAR RAPID Prime – HRT36 – USP 0 colourless – 90 cm (this product)
AMP222HRT3620 (P222HRT3620) PGAR RAPID Prime – HRT36 – USP 2/0 colourless – 75 cm (same geometry, smaller gauge)
AMP222HR3610 (P222HR3610) PGAR RAPID Prime – HR36 conical point – USP 0 colourless – 75 cm (conical point for soft tissues)
AM223HR4010 PGAR RAPID – HR40 conical point – USP 0 colourless – 90 cm (longer needle, standard range)
AM22-3.4510 (22-3.4510) PGAR RAPID without needle – USP 0 colourless – 3 × 45 cm (for ligatures and manual sutures)

Sterility and storage: product sterilised by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference P223HRT3610 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Material

100% polyglactic acid (PGAR) braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 0 (metric 3.5 / EP 3.5)

Thread diameter

0.35 – 0.399 mm

Needle shape

½ circle (1/2 circular)

Needle tip

Cylindrical body with trocar point (Tapercut)

Needle size

HRT 36 Prime (36 mm), 1 needle per thread

Swaged

1 needle / 1 suture

Sterilisation

Gamma radiation, single-use, not re-sterilisable

Presentation

Box of 12 units; minimum order 30 boxes

Manufacturer reference

P223HRT3610

Regulatory standard

Conforms to USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 36

Usp

0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGAR RAPID Prime · ½ Circle Needle Cylindrical Body Trocar Point (Tapercut) 36 mm HRT36 · USP 0 Colourless 90 cm · Box of 12 units (Ref. P223HRT3610)”

Your email address will not be published. Required fields are marked *