Absorbable Multifilament Suture PGAR RÁPIDO Prime · Half-Circle Needle Cylindrical Body Conical Taperpoint Point 36 mm (HR36) · USP 2/0 (Metric 3) Undyed · Thread 90 cm · PREMISUT RÁPIDO · Ref. P223HR3620 · Box of 12 units

Original price was: 43,19 €.Current price is: 34,80 €.

Absorbable multifilament suture PREMISUT RÁPIDO in Prime quality (100 % polyglycolic acid with rapid absorption, PGAR), mounted with a half-circle needle with cylindrical body and conical Taperpoint point of 36 mm (HR36 profile): atraumatic passage that separates the fibres without a cutting effect. USP gauge 2/0 (metric 3), undyed 90 cm thread coated with polycaprolactone and calcium stearate for smooth sliding and a firm knot. Predictable absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength at day 5 and loses it at day 14. Sterilised by gamma radiation, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and general surgery. Factory ref. P223HR3620 · SKU AMP223HR3620 · Price per box of 12 units (minimum order 30 boxes).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP223HR3620

Description

1. Commercial Introduction

The rapid-absorption multifilament PGAR suture from the PREMISUT RÁPIDO range in Prime quality is the accelerated-absorption closure solution for the professional who needs a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This configuration combines a braided strand of 100% polyglactic acid in USP 2/0 gauge, colourless and 90 cm long, with a ½ circle needle with cylindrical body and conical point (Taperpoint) of 36 mm: atraumatic passage and minimal tissue damage, ideal for approximation of soft tissues, ligatures and general surgery. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability; aimed at hospital replenishment, purchasing centres, clinics and B2B tenders.

2. Technical Explanation

PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer 100% absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength. Its degradation profile is designed for short-term healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR36 needle features a ½ circle curvature (1/2, 160°) with cylindrical body and Taperpoint conical point: the round body allows clean passage through soft tissues and the conical point separates fibres without an aggressive cutting effect, minimising trauma to the puncture bed. Sterilised by gamma radiation; single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P223HR3620 · SKU AMP223HR3620)

Parameter Specification
Factory reference P223HR3620 (Prime range)
Reference Cahnos (SKU) AMP223HR3620
Brand / quality PREMISUT RAPID (Prime range)
Thread material 100 % polyglactic acid (PGAR), braided multifilament
Coating Polycaprolactone and calcium stearate
Gauge / size USP 2/0 (metric 3 / EP 3), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.30 – 0.339 mm
Thread length 90 cm (free end, without loop)
Thread colour Colourless
Needle shape ½ circle (1/2, 160°), cylindrical body
Tip type Conical / Taperpoint
Needle size HR 36 Prime (36 mm), 1 needle per suture
Swaged 1 needle / 1 suture per unit
Absorption By hydrolysis, completed between 40 and 45 days
Sterilisation Gamma radiation; sterile, single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures and general surgery
Commercial presentation Box of 12 units (individual sterile sachets); minimum order of 30 boxes
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR)

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid-absorption formulation (RÁPIDO line); it must not be confused with standard-absorption polyglycolic acid (PGA line, 60–90 days) or with standard polyglactin 910 (56–72 days), also available in our catalogue.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
2/0 (this product) 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.

3.4. Decoding of the official reference

The official reference P223HR3620 decodes as: P (Prime quality) + 223 (90 cm thread) + HR36 (½ circle needle with cylindrical body and 36 mm Taperpoint conical point) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.

4. Equivalences and Cross-References

The reference P223HR3620 corresponds to the official nomenclature of the PREMISUT RÁPIDO range (rapid-absorption polyglactic acid, multifilament, USP 2/0, colourless 90 cm thread, ½ circle cylindrical needle with 36 mm Taperpoint conical point, Prime quality). Rapid-absorption polyglycolic acid (PGAR) is one of the most widespread short-term braided absorbable suture families on the market and can be homologated at clinical category level with the rapid lines of major manufacturers. The following reference has been cross-checked against the manufacturer’s official catalogue and authorised distribution:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) V9450H (EMEA) / VR945 Comparable by category (not interchangeable 1:1) They match: USP 2/0 gauge, colourless 90 cm thread, ½ circle 36 mm needle with Taperpoint conical point (CT-1) and rapid-absorption profile (≈42 days). They differ: the base polymer (polyglactin 910 versus polyglactic acid), the braid coating and the packaging format. Code confirmed in manufacturer sources and authorised distributors.

The other homologous lines in the rapid-absorption segment (Safil Quick and NOVOSYN QUICK from B. Braun, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI) must be reviewed property by property —material, USP 2/0 gauge, multifilament structure, ½ circle curvature, conical point family, 36 mm needle length, 90 cm thread length, colourless colour, 1-needle configuration and CE/MDR regulatory classification— before any substitution; they are not included in the table because no verified code is available for this exact combination. Standard VICRYL (56–72 day absorption) is not comparable to this RÁPIDO version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department of Cahnos before use in tenders. Within the PREMISUT system itself, the PGAR RÁPIDO family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided gauge and needle geometry are respected.

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) is a medium size that balances strength and fineness, indicated for planes with moderate tension: approximation of subcutaneous tissue and fascia, closure of skin and mucosa, ligation of small-calibre vessels and general surgery when wound support does not exceed 14 days. The HR36 ½ circle needle with Taperpoint conical point passes through soft tissues separating fibres without a cutting effect: a recommended option for lax, well-perfused tissues where an atraumatic passage and minimal bleeding are sought. If the tissue is denser, consider the same family with Tapercut trocar point (HRT36) or reverse cutting (HS36). The colourless colour offers maximum discretion in the field and is preferred in aesthetic or superficial tissue areas.

Variant / Reference Description
AM223HR3620 (223HR3620) PGAR RÁPIDO – HR36 conical point – USP 2/0 undyed – 90 cm (same configuration, standard range; direct equivalent within the same manufacturer)
AMP222HR3620 (P222HR3620) PGAR RÁPIDO Prime – HR36 conical point – USP 2/0 undyed – 75 cm (same needle and gauge, shorter thread)
AMP223HR3610 (P223HR3610) PGAR RÁPIDO Prime – HR36 conical point – USP 0 undyed – 90 cm (larger gauge, same needle)
AMP223HR3601 (P223HR3601) PGAR RÁPIDO Prime – HR36 conical point – USP 1 undyed – 90 cm (larger gauge for planes under higher tension)
AMP223HRN3620 (P223HRN3620) PGAR RÁPIDO Prime – HRN36 blunt point – USP 2/0 undyed – 90 cm (blunt point for minimal tissue damage)
AM223HS3620 (223HS3620) PGAR RÁPIDO – HS36 reverse cutting – USP 2/0 undyed – 90 cm (triangular point for skin and dense tissues)

Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference P223HR3620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Material

100% polyglactic acid (PGAR), braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2/0 (metric 3)

Thread diameter

0.30 – 0.339 mm

Needle shape

½ circle (1/2, 160°), cylindrical body

Needle tip

Taperpoint conical

Needle size

HR 36 (36 mm)

Swaged

1 needle / 1 suture

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation

Presentation

Box of 12 units; minimum order 30 boxes

Manufacturer reference

P223HR3620

Regulatory standard

USP/EP; CE marking (MDR)

Medida de aguja

HR 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)