We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RAPID Prime USP 0 Undyed 75 cm – 1/2 Circle Cylindrical Taper Point Needle 30 mm (Ref. P222HR3010)

Original price was: 44,90 €.Current price is: 34,80 €.

Absorbable multifilament suture PREMISUT RAPID (polyglycolic acid, PGAR Prime) with a ½ circle needle with cylindrical body and taper point (Taperpoint) of 30 mm. USP gauge 0, undyed 75 cm thread, rapid hydrolysis absorption in 40-45 days and retention of 50 % of strength at 5 days. Sterilised by gamma radiation; presentation in a box of 12 units with a minimum order of 30 boxes. Reference P222HR3010. Ideal for approximation of soft tissues, ligatures and general surgery.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP222HR3010

Description

Absorbable polyglycolic acid suture with rapid absorption

The PREMISUT RAPID PGAR suture is the reference choice for procedures requiring short-term wound support with predictable reabsorption and no need to remove the material. Its Prime-quality polyglycolic acid (PGAR) formulation combines excellent initial tensile strength with smooth passage through tissue, thanks to the coating of polycaprolactone and calcium stearate.

Technical features of the thread and needle

It is a synthetic absorbable suture of the braided and coated multifilament type. Absorption occurs by hydrolysis, with a gradual and controlled loss of strength: it retains 50 % of its original tensile strength at 5 days and loses virtually all strength at 14 days, with complete reabsorption between 40 and 45 days. The ½ circle needle with cylindrical body and taper point (Taperpoint) of 30 mm is designed to pass through soft tissues with minimal injury, facilitating suturing of internal planes, tissue approximation and ligatures in general surgery, gynaecology and urology.

Technical specifications

Material 100 % polyglycolic acid (PGAR) braided multifilament
Coating Polycaprolactone and calcium stearate
Gauge USP 0
Thread length 75 cm
Needle ½ circle, cylindrical body, taper point (Taperpoint), 30 mm
Colour Colourless
Absorption 40-45 days by hydrolysis
Tensile strength 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation
Quality Prime
Reference P222HR3010 (SKU AMP222HR3010)
Presentation Box of 12 units · Minimum order 30 boxes

Equivalences and cross-references

This suture belongs to the category of braided synthetic absorbables with rapid absorption, a segment in which the most recognised clinical reference is Ethicon’s VICRYL RAPIDE family (low molecular weight polyglactin 910). Both share the same functional concept: braided multifilament, undyed, hydrolysis absorption in around 40-45 days and short-term wound support. However, as they are different polymers (polyglycolic acid versus polyglactin 910), the comparison is at category level and not interchangeable 1:1 without validation from the purchasing department.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, braided coated) PV1694H (according to Ethicon catalogue: MH-1 needle of 31 mm, ½ circle cylindrical, USP 0, undyed, 90 cm) Comparable by category (not interchangeable 1:1) Different polymer (polyglactin 910 vs polyglycolic acid); needle 31 mm versus 30 mm; thread 90 cm versus 75 cm. Verify availability and exact version in the Ethicon catalogue.

As homologous brands and families in this rapid absorption segment, B. Braun with its Safil Quick line (rapid absorption polyglycolic acid) and the PREMISUT RAPID family itself in its PGLAR variant (polyglactin 910, ½ circle cylindrical needle) are also cited. Before substituting in a tender or bid, the USP gauge, needle type and size, thread length and absorption profile must be checked in each manufacturer’s technical data sheet. There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender.

Selection tips and variants of interest

For superficial planes and fast-healing tissues, this USP 0 presentation with a 30 mm cylindrical needle is suitable for general surgery and approximation of internal planes. If greater penetration power is required in dense tissues, consider the variant with a reverse cutting triangular needle (DS) of the same gauge; and if a finer gauge is sought for paediatrics or minor surgery, the PREMISUT RAPID family offers 3/0 and 4/0 presentations with a 17 mm needle in the same ½ circle cylindrical geometry. Always request verification of the batch, expiry date and sterility seal before use.

Additional information

Material

Polyglycolic acid (PGAR) braided multifilament

Coating

Polycaprolactone and calcium stearate

Needle

½ circle, cylindrical body, taper point (Taperpoint), 30 mm

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation

Reference

P222HR3010

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 30

Usp

0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGAR RAPID Prime USP 0 Undyed 75 cm – 1/2 Circle Cylindrical Taper Point Needle 30 mm (Ref. P222HR3010)”

Your email address will not be published. Required fields are marked *