We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture Polyglactin 910 RAPID PGLAR Prime | Needle ½ Circle Cylindrical Taperpoint Conical Point 22 mm (HR22) · USP 2/0 (Metric 3) · Colourless · Thread 75 cm | PREMISUT RAPID · Box of 12 units (Ref. P2L22HR2220)

Original price was: 43,49 €.Current price is: 34,80 €.

Absorbable multifilament suture PREMISUT RAPID polyglactin 910 (PGLAR) in Prime quality, mounted with a ½ circle needle with cylindrical body and Taperpoint conical point of 22 mm (HR 22). USP gauge 2/0 (metric 3), colourless grooved thread of 75 cm, sterile by gamma radiation and single-use. Predictable absorption by hydrolysis in 40–45 days, with 50 % retention of tensile strength at 5 days and total loss at 14 days: ideal short-term support for fast-healing tissues without suture removal. Indicated for approximation of soft tissues, ligatures and ophthalmic surgery. Manufacturer reference P2L22HR2220 · Price per box of 12 units · Minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22HR2220

Description

1. Commercial Introduction

The Absorbable Multifilament PGLAR Polyglactin 910 RAPID Suture in Prime quality is the high-performance solution for operating theatres, general and ambulatory surgery departments, ophthalmology, emergency services and B2B purchasing centres that require a fast-acting absorbable braided thread with excellent handling and maximum knot security. It is supplied with a ½ circle needle with cylindrical body and 22 mm Taperpoint conical point (HR 22), USP 2/0 gauge, 75 cm colourless grooved thread, in a box of 12 units. A sterile, single-use product designed for fast-healing tissues that require short-term support, offering an optimal balance between clinical performance and cost per pack.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish and lubricating coating that facilitates smooth passage through tissue, excellent handling and firm, secure knot tying. In the RAPID variant, the polymer has a low molecular weight and accelerates the loss of strength and mass: it retains 50% of the initial tensile strength at 5 days and loses all its strength at 14 days, with complete absorption by hydrolysis between 40 and 45 days and minimal tissue reaction.

The ½ circle (160°) needle with cylindrical body and Taperpoint conical point passes through soft tissues by separating the fibres without tearing them, minimising tissue trauma. The colourless thread offers maximum discretion on the surgical field, a quality especially valued in ophthalmic surgery. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised: check the integrity of the packaging and the expiry date before each procedure.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22HR2220 · SKU AMP2L22HR2220)

Parameter Specification
Thread material Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID)
Thread structure Braided coated multifilament, fluted finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 2/0 (metric 3); approximate diameter 0.30 – 0.339 mm according to Pharmacopoeia
Thread colour Colourless
Thread length 75 cm
Needle shape Half circle (1/2, 160°)
Needle body Cylindrical
Needle tip Conical grooved (Taperpoint)
Needle size HR 22 mm (Prime)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 %
14 days 0 %
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

4. Equivalences and Cross-References

Fast-absorbing polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable suture on the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line (polyglactin 910), with which this reference shares material, accelerated absorption profile (≈42 days), tensile retention (50% at 5 days / 0% at 14 days), USP 2/0 gauge, colourless thread and 75 cm length. Only codes whose attributes have been verified in industry sources (manufacturer catalogue and authorised distributors) are included:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (braided poliglactin 910, undyed), PS 3/8 circle needle with reverse cutting point 26 mm, 75 cm W9933 (EMEA) Comparable by category (not interchangeable 1:1) Same material, fast absorption (wound support 7-10 days), USP 2/0 gauge, 26 mm needle and 75 cm colourless thread. They differ in curvature (3/8 circle vs ½ circle), point (reverse cutting vs Taperpoint conical) and needle size (26 mm vs HR 22 mm). Code confirmed in EMEA catalogue and authorised distributors.
Ethicon (J&J MedTech) VICRYL RAPIDE (braided poliglactin 910, undyed), MH-1 ½ circle needle with conical point 31 mm, 75 cm W9975 (EMEA) Comparable by category (not interchangeable 1:1) Same material, fast absorption (≈42 days), USP 2/0 gauge (metric 3), ½ circle curvature, conical point and 75 cm colourless thread. They differ in needle size (MH-1 31 mm vs HR 22 mm) and the exact needle finish. Code confirmed in EMEA catalogue and authorised distributors.

Reference homologous ranges in the sector include the fast-absorbing braided polyglactin 910 sutures from B. Braun (lines such as Safil Quick / Novosyn Quick), DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb), whose specific codes for the exact combination USP 2/0 / Taperpoint conical needle HR 22 mm / 75 cm thread / colourless must be confirmed with each manufacturer. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version in terms of tensile strength retention. There is no manufacturer-validated equivalence table cross-referencing this product with other brands; consult the technical department before use in tenders, verifying in each official datasheet the USP 2/0 gauge (metric 3), the ½ circle curvature, the needle type and size (22 mm Taperpoint conical), the thread length (75 cm) and the colourless colour.

5. Selection tips and variants of interest

To choose the most appropriate suture, consider the wound support time required by the tissue and the gauge according to the anatomical area. USP 2/0 gauge with a 22 mm Taperpoint conical needle is a common choice for approximating skin and mucous membranes, subcutaneous tissue, ligation of small and medium-calibre vessels and ophthalmic surgery, with early strength loss that in many indications avoids the need for suture removal. The ½ circle needle with conical point is especially recommended when an atraumatic passage through soft, well-perfused tissues is sought, without any cutting effect.

Within the same PGLAR Polyglactin 910 RAPID range with cylindrical conical-point needle, Cahnos offers complementary configurations: the standard quality version with identical dimensions (SKU AM2L22HR2220), the Prime double-thread variant 2 x 75 cm (SKU AMP2L22HR2220.2), the 3/0 and 4/0 gauges on the same HR 22 mm needle (SKU AMP2L22HR2230 and AMP2L22HR2240), as well as HR 26 and HR 30 mm needles in 2/0 gauge (SKU AM2L22HR2620 and AM2L22HR3020). All references are supplied in boxes of 12 units. For longer tensile support, consider the standard polyglactin 910 family (absorption 56-72 days).

As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial brands, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID)

Structure

Braided coated multifilament, fluted finish

Gauge

USP 2/0 (metric 3)

Needle shape

Half circle (1/2, 160°)

Needle body

Cylindrical

Needle tip

Conical grooved (Taperpoint)

Needle size

HR 22 mm (Prime)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Quality

Prime (PREMISUT RAPID range)

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P2L22HR2220

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Medida de aguja

HR 22

Usp

2/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture Polyglactin 910 RAPID PGLAR Prime | Needle ½ Circle Cylindrical Taperpoint Conical Point 22 mm (HR22) · USP 2/0 (Metric 3) · Colourless · Thread 75 cm | PREMISUT RAPID · Box of 12 units (Ref. P2L22HR2220)”

Your email address will not be published. Required fields are marked *