Description
At Cahnos we offer you the absorbable multifilament suture of polyglycolic acid (PGA) from the Prime line (PREMISUT), reference AMP112GS6020, a professional solution for B2B procurement for operating theatres, purchasing centres and general surgery services.
This presentation incorporates a straight needle with triangular point and conventional cutting edge of 60 mm (GS60), violet thread of 75 cm in USP 2/0 gauge and reliable knotting capacity, ideal conditions for tissue approximation, ligatures and general surgery with direct access to the surgical field. Predictable behaviour, excellent initial tensile strength, minimal tissue reaction and special hospital supply conditions for volume contracts.
Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure coated with polycaprolactone and calcium stearate, which gives it a smooth, non-grooved surface that slides gently through tissue, minimising the sawing effect and tissue reaction. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread maintains mechanical tissue support during the critical phase of healing (75% of strength at 2 weeks, 50% at 3 and 40% at 4) and is reabsorbed progressively and controlled between 60 and 90 days.
The GS60 straight needle of 60 mm, with triangular point and conventional cutting edge, facilitates penetration into resistant and inelastic tissues, allowing manual suturing on surfaces with direct access and absolute control of the path. It is the usual configuration for approximation stitches, superficial continuous sutures and ligatures. The violet colour improves the visibility of the thread over the surgical field, and its sterilisation by ethylene oxide (EO) guarantees the sterility of the single-use device until the packaging is opened.
Technical specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP112GS6020 |
| Tariff reference (PREMISUT) | P112GS6020 |
| Brand / Quality | PREMISUT – Prime line |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / USP size | USP 2/0 (metric 3) |
| Thread length | 75 cm |
| Needle shape | Straight |
| Tip type | Triangular – conventional cutting |
| Needle size | GS60 (60 mm) |
| Thread colour | Violet (also available undyed depending on presentation) |
| Absorption | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
Tensile strength retention profile
| Time point | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60 – 90 days |
Equivalences and cross-references
Multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable on the market, and the configuration of straight triangular needle of 60 mm in USP 2/0 gauge is one of the most demanded for manual suturing. The homologous commercial ranges of reference are the AssuCryl® line from Assut (braided PGA coated with polycaprolactone and calcium stearate, absorption of 60-90 days), the PGA line from Laboratorio Aragó with straight triangular needle TR-60, as well as the PGA series from manufacturers such as WEGO, Dolphin Sutures or CP Medical. In the segment of polyglactin 910 (PGLA), a material of the same clinical family although of different composition (copolymer of glycolide and L-lactide), are the Vicryl (Ethicon), Safil (B. Braun) and Polysorb (Covidien/Medtronic) ranges.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Laboratory Aragó | PGA (polyglycolic acid), straight triangular needle TR-60 | 4301712 | Comparable by category (not interchangeable 1:1) | Same material (PGA), USP 2/0 gauge and straight triangular needle of 60 mm; differs in colour (colourless vs violet), thread length (70 cm vs 75 cm) and absorption profile (90 days, tensile strength retention 28-30 days) |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (straight needle with conventional cutting edge GS60 of 60 mm, USP 2/0 gauge, violet thread of 75 cm) with references from other commercial houses. The identified matches must be treated as functional category comparisons and not as 1:1 interchangeable without technical validation: for example, reference 4220936 from Laboratorio Aragó (distributor code 9100024) corresponds to PGA Rapid with straight needle TR-60 in USP 2/0 gauge, colourless strand of 70 cm, but presents a rapid absorption profile (about 40 days) different from that of this suture; and in the Assut catalogue the confirmed straight cutting needle presentations are the RS-45 and RS-58 series of the AssuCryl® range, without having located an RS-60 that exactly replicates this configuration. Consult the technical department of Cahnos before using this information in tenders or in the direct substitution of references. The cited brands belong to their respective manufacturers and are mentioned only as a reference of equivalence.
Selection tips and variants of interest
- Gauge: USP 2/0 is suitable for tissues with medium mechanical demand and for ligatures; 3/0 for skin and subcutaneous tissue; and 4/0 for fine tissues and precision surgery.
- Needle: the straight needle with conventional cutting edge is ideal for approximation and ligature sutures with direct access to the surgical field; for microsurgery and tissues with limited access, consider versions with a 3/8 circular needle.
- Colour: if you prefer maximum visibility over the field, keep the violet presentation; for maximum aesthetic discretion you have the colourless version (ref. AMP128GS6020, USP 2/0, GS60, 70 cm).
- Quality: the Prime line offers a regular surface and smooth sliding that minimises tissue damage; if your budget is tighter, the standard quality (ref. AM112GS6020) maintains the same technical performance with conventional quality control.
- Within the Cahnos catalogue: you can complete your stock with the PGLA (polyglactin 910) version of the same GS60 format (ref. P1L12GS6020), the 3/0 gauge of the same line (ref. AMP112GS6030) or the presentation with 3/8 circular needle (ref. AMP112DS3020).
- Storage: as it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight.
For special B2B conditions by volume, hospital supply agreements or queries about equivalences from other commercial houses, contact the technical-commercial team of Cahnos.