Description
1. Product Presentation
At Cahnos we offer this absorbable multifilament suture of polyglycolic acid (PGA) from the Prime line (PREMISUT), reference AMP128GS6020, a professional solution for the B2B supply of operating theatres, purchasing centres and general surgery departments. The presentation incorporates a straight needle with a triangular point and conventional cutting edge of 60 mm (model GS60), a colourless 70 cm thread in USP 2/0 (metric 3) and reliable knot-holding capacity, ideal conditions for the approximation of tissues with medium mechanical requirements, ligatures and general surgery with direct access to the surgical field. Predictable behaviour, excellent initial tensile strength, minimal tissue reaction and special hospital supply conditions for volume contracts.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented as a braided multifilament structure coated with polycaprolactone and calcium stearate, which gives it a smooth, non-grooved surface that slides gently through tissue, minimising the sawing effect and tissue reaction. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread maintains mechanical tissue support during the critical phase of healing (75% of strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks) and is reabsorbed progressively and controllably between 60 and 90 days.
The straight GS model needle of 60 mm, with a triangular conventional cutting point, facilitates penetration into resistant, inelastic tissues, allowing manual suturing on accessible surfaces with absolute control of the needle path. It is particularly useful for approximation stitches, superficial continuous sutures and ligatures with direct access. The colourless thread favours aesthetic discretion without interfering with visualisation of the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP128GS6020 |
| Tariff reference (PREMISUT) | P128GS6020 |
| Brand / Quality | PREMISUT – Prime line |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / USP size | USP 2/0 (metric 3) |
| Thread length | 70 cm |
| Needle shape | Straight |
| Tip type | Triangular – conventional cutting |
| Needle size | 60 mm (GS60 model) |
| Thread colour | Colourless (also available in violet in other presentations) |
| Absorption | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
Tensile strength retention profile
| Time point | Strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60 – 90 days |
4. Equivalences and Cross-References
Multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable on the market, and the 60 mm straight triangular needle configuration (GS60) in USP 2/0 is one of the most in demand for manual suturing. The following matches have been checked against the official catalogue of the cited manufacturer (Assut Europe, ASSUFIL® and GLICOFIL® LAC technical data sheets, GS60 straight triangular needle section). In Assut’s official catalogue, the GS60 straight triangular needle series is presented with a standard 36 cm thread, so the references indicated differ in thread length compared with the 70 cm of this suture.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Assut Europe (Italy) | ASSUFIL® – Braided and coated PGA (average absorption 60-90 days) | FU56436 | Comparable by category (not interchangeable 1:1) | GS60: 60 mm straight triangular needle, USP 2/0 (EP 3), standard 36 cm thread in the official catalogue. Same molecule (PGA), same polycaprolactone and calcium stearate coating and same absorption window (60-90 days). Tensile retention declared by the manufacturer: 90%/7 days, 75%/14 days, 50%/21 days, 30%/28 days. Thread length differs (36 cm vs 70 cm) and batch control; validate before substitution. |
| Assut Europe (Italy) | ASSUFIL® – braided and coated PGA (alternative gauge) | FV56336 | Comparable by category (not interchangeable 1:1) | Same GS60 60 mm needle geometry and same standard 36 cm thread, in USP 3/0 (EP 2). Alternative gauge within the same technical family of the manufacturer. |
| Assut Europe (Italy) | GLICOFIL® LAC – Braided and coated PGLA (average absorption 56-70 days) | FU564L36 | Comparable by category (not interchangeable 1:1) | GS60: 60 mm straight triangular needle, USP 2/0 (EP 3), standard 36 cm thread. Different composition: copolymer of glycolide (90%) and lactide (10%), with absorption of 56-70 days and a tensile retention profile of 90%/7 days, 75%/14 days, 50%/21 days, 25%/28 days. Not interchangeable 1:1 due to composition and absorption profile. |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (GS60 60 mm straight conventional cutting needle, USP 2/0, colourless 70 cm thread) with references from other commercial houses; consult the technical department before use in tenders. The above matches should be treated as functional category comparisons and not as 1:1 interchangeable without technical validation. In the Laboratorio Aragó range, the existence of the TR-60 60 mm straight triangular needle (equivalent geometry format) has been verified, but the manufacturer numerical codes circulating in some distributor data sheets (e.g. 4301712 and 4220936) could not be verified in public sources; unverifiable code, confirm with the manufacturer before use. In the polyglactin 910 (PGLA) segment, a material of the same clinical family although of different composition (copolymer of glycolide and L-lactide), are the Vicryl® (Ethicon), Safil® (B. Braun) and Polysorb™ (Medtronic) ranges, as well as the PGA series from WEGO and Surgicryl® (SMI), without an exact configuration of 60 mm straight needle, 70 cm thread and gauge 2/0 having been found in official sources for these brands. The brands cited belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: 2/0 is suitable for tissues with medium mechanical requirements, ligatures and approximation of planes; 3/0 for skin, subcutaneous tissue and soft tissues under moderate tension; and 4/0 for fine tissues and precision surgery. The straight conventional cutting needle is ideal for approximation and ligature sutures with direct access to the surgical field.
Variants of interest within the Cahnos catalogue in the same GS60 format:
- AM128GS6020: standard-grade PGA, straight GS60 needle, USP 2/0, undyed, 70 cm (same configuration without the Prime line).
- AMP128GS6030 / AMP128GS6040: PGA Prime, straight GS60 needle, USP 3/0 and 4/0, undyed, 70 cm (alternative gauges of the same format).
- AMP112GS6020: PGA Prime, straight GS60 needle, USP 2/0, violet, 75 cm (greater thread visibility on the field).
- P1L28GS6020: PGLA (polyglactin 910) Prime, straight GS60 needle, USP 2/0, undyed, 70 cm (same needle geometry; copolymer material with absorption of 56-72 days).
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or enquiries about equivalents from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.