Description
1. Commercial Introduction
The Absorbable Multifilament PGA Suture with a 31 mm trocar point hook needle is the trusted choice for the professional seeking a synthetic reabsorbable thread with predictable behaviour, excellent handling and maximum knot security. Its braided structure facilitates manipulation during surgery and its coating of polycaprolactone and calcium stearate ensures optimal sliding with minimal tissue trauma.
Available in B2B presentation in boxes of 12 units with a minimum order of 30 boxes, this reference offers an excellent value for money for hospitals, clinics, purchasing centres, operating theatres and distributors of surgical material who need to replenish general-purpose absorbable suture.
2. Technical Explanation
It is a braided (multifilament) absorbable synthetic suture made from 100% polyglycolic acid (PGA) and coated with polycaprolactone and calcium stearate. This coating favours the sliding of the thread through the tissue, reduces the sawing effect, provides low shape memory and guarantees firm and secure knot tying even in gauges of high initial resistance such as USP 1.
Absorption occurs by hydrolysis, a degradative process independent of the patient’s enzymatic activity, over a predictable period of 60 to 90 days. The 31 mm JRT needle combines a cylindrical hook-shaped body (J-Hook) with a trocar point (tapercut): it penetrates firm tissues by separating the fibres without a cutting effect, minimising trauma to delicate structures. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Reference (SKU) | AM112JRT3101 |
| Factory reference | 112JRT3101 |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Thread structure | Braided coated multifilament, fluted finish |
| Coating | Polycaprolactone and calcium stearate |
| USP / metric gauge | USP 1 (metric 4) |
| Approximate diameter | 0.40 – 0.499 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet grooved |
| Thread length | 75 cm |
| Needle shape | Hook, J-Hook format (J-shaped) |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | JRT 31 mm |
| Quality | Normal (range PREMISUT) |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Absorption mechanism | Hydrolysis (60 – 90 days) |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Complete absorption | 60 – 90 days, by hydrolysis |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction during the critical healing period.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most well-established raw materials for synthetic multifilament absorbable sutures on the market. This braided suture with medium absorption (60-90 days by hydrolysis) is comparable at category level with the homologous lines of the main international manufacturers in the same PGA polymer or in polyglactin 910: Ethicon (Coated VICRYL™ / VICRYL™ Plus), B. Braun (Safil® and Novosyn®), Medtronic (Polysorb, Dexon II), SMI (Surgicryl® PGA), DemeTECH (DemeSORB PGA), Assut (Assucryl 910), Dolphin Sutures (Petcryl) and CPT Sutures (CARESYN).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL™ (polyglactin 910) | W9335 | Comparable by category (not interchangeable 1:1) | Same functional format: heavy hook-type needle with 31 mm tapercut trocar point (V-38), USP 1 gauge, violet braided thread 75 cm. Differences: polyglactin 910 (PGLA) composition versus pure PGA and faster absorption profile (56-72 days). |
| B. Braun | Safil® / Novosyn® (PGLA) | Not verified for this configuration | Not verified | Comparable by category; the trocar point references verified in public sources correspond to ⅝ or ½ circle curvatures, not to the 31 mm J-hook geometry. Confirm with the manufacturer before use. |
| Medtronic | Polysorb™ (PGLA) | Not verified for this configuration | Not verified | Comparable by category; no purchase code locatable in public sources for the combination of J-hook needle 31 mm trocar / USP 1 / 75 cm. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders or direct substitution. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (31 mm), J-shaped curvature, point family (trocar tapercut), thread length (75 cm) and colour.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscle planes, abdominal wall and high-tension closures. The J-hook needle with 31 mm trocar point combines ergonomic access to deep planes with controlled penetration, minimising tissue damage compared with conventional cutting points.
| Reference | Variant of interest |
| AMP112JRT3101 | PGA Prime, JRT31 needle trocar point, USP 1, violet, 75 cm (superior range, same configuration) |
| 1L12JRT3101 | PGLA Polyglactin 910, JRT31 needle, USP 1, violet, 75 cm (absorption 56-72 days) |
| P1L12JRT3101 | PGLA Polyglactin 910 Prime, JRT31 needle, USP 1, violet, 75 cm |
| AM112JR3601 | PGA USP 1, JR36 hook needle taperpoint conical point, violet, 75 cm (larger needle radius) |
| AM112JR3610 | PGA USP 0, JR36 hook needle conical point, violet, 75 cm (intermediate gauge) |
| AM112JR3620 | PGA USP 2/0, JR36 hook needle conical point, violet, 75 cm (finer gauge) |
| AMP418JRT3101 | PDO Polydioxanone Prime, JRT31 needle, USP 1, violet, 70 cm (prolonged absorption 180-210 days) |
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews