We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture | ⅜ Circle Triangular Point Reverse Cutting Needle 24 mm (DS 24) | USP 0 (Metric 3.5) | Violet Fluted Thread 75 cm | Ref. P112DS2410 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Multifilament absorbable suture of polyglycolic acid (PGA) in Prime quality with ⅜ circle needle, reverse cutting triangular point of 24 mm (DS 24) and 75 cm grooved violet braided thread. USP 0 calibre (metric 3.5), absorption by hydrolysis in 60-90 days with strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Ref. P112DS2410, presentation in box of 12 units with minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP112DS2410

Description

1. Commercial Introduction

The PGA Prime multifilament absorbable suture reference P112DS2410 is the reference solution for professionals seeking a surgical thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ⅜ circle needle with reverse cutting triangular point of 24 mm (DS 24) ensures firm, controlled penetration even in tissues of a certain consistency, while the 75 cm violet braided thread offers optimal visibility on the surgical field and smooth sliding during suturing.

It is a synthetic absorbable, sterile, single-use medical device with an excellent quality-price ratio for B2B supply to operating theatres, clinics, purchasing centres and distributors. Presentation in a box of 12 units with a minimum order of 30 boxes, designed to ensure continuous supply for your healthcare facility.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish, coated with polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in working calibres such as USP 0.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and avoiding tearing. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and is not resterilisable.

3. Technical Specifications

3.1. General characteristics of reference P112DS2410

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Factory reference P112DS2410 (SKU: AMP112DS2410)
Material 100% polyglycolic acid (PGA) absorbable by hydrolysis
Coating Polycaprolactone and calcium stearate for better sliding
Thread structure Braided multifilament with grooved finish
Gauge USP 0 (metric 3.5)
Thread colour Violet
Thread length 75 cm
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (reverse cutting)
Needle size DS 24 (24 mm)
Absorption mechanism By hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of the initial strength
3 weeks 50% of the initial strength
4 weeks 40% of the initial strength
Complete absorption 60-90 days (hydrolysis)

3.3. Gauge equivalence (indicative according to Pharmacopoeia)

USP size Metric size Approximate diameter
0 3.5 0.35 – 0.399 mm

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. Braided polyglycolic acid (PGA) is the medium-duration multifilament absorbable par excellence and has commercial counterparts on the market, but each manufacturer applies its own coatings, finishes and absorption profiles, so no external reference should be treated as 1:1 interchangeable without verification of the technical data sheet and IFU.

Comparable at category level (not 1:1 interchangeable) – same 100% braided PGA polymer: the Safil® line from B. Braun (pure braided and impregnated polyglycolic acid, violet or colourless, absorption by hydrolysis around 60-90 days). The coating differs (polyglyconate in Safil versus polycaprolactone and calcium stearate in this reference) and the needle system, so calibre, thread length and needle geometry must be checked before any substitution. Historically, Dexon II (Medtronic/Covidien) is also cited as a reference braided PGA, without uniform current availability on the European market.

Comparable at category level (not 1:1 interchangeable) – different copolymer, same clinical indication: the polyglactin 910 (PGLA) lines such as Vicryl® (Ethicon), Novosyn® (B. Braun), Polysorb® (Medtronic), Surgicryl® (SMI) and Assucryl 910 (Assut) present a very similar absorption profile (56-72 days) and the same general application, but they are a copolymer of glycolide and L-lactide, not pure PGA, with their own coatings and strength curves: they are not exact reference equivalents. Within the Cahnos catalogue itself, the identical configuration in the standard range (reference AM112DS2410) and in polyglactin 910 Prime (P1L12DS2410) allow warehouse standardisation; for formal substitution of references in tendering, always consult the technical-commercial department.

5. Selection tips and variants of interest

To choose the most appropriate suture, assess the wound support time required by the tissue to be sutured and the calibre according to the anatomical area. USP 0 calibre (metric 3.5) offers high initial strength, suitable for tissues with moderate or high tension: aponeurosis, fascia, muscle planes and ligatures. The reverse cutting triangular point needle (DS 24) is especially recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis).

Reference Variant
AMP112DS2410 PGA Prime USP 0, ⅜ triangular needle DS 24 mm, violet, 75 cm (current product)
AMP112DS2420 PGA Prime USP 2/0, same DS 24 mm needle, violet, 75 cm (finer gauge)
AMP112DS2430 PGA Prime USP 3/0, same DS 24 mm needle, violet, 75 cm (finer gauge)
AMP122DS2430 PGA Prime USP 3/0, same needle DS 24 mm, undyed, 75 cm (maximum discretion in the surgical field)
AMP118DS2440 PGA Prime USP 4/0, needle DS 24 mm, violet, 70 cm (fine gauge)
AM112DS2410 Standard PGA USP 0, same DS 24 mm configuration (standard range)
P1L12DS2410 PGLA Prime USP 0, same DS 24 mm configuration (absorption 56-72 days)

In the Cahnos catalogue you also have other thread lengths, calibres from 6/0 to 2, double-needle versions and other needle geometries (DS of 16, 19, 26, 30 and 36 mm, precision XDS and cylindrical types), as well as the prolonged absorption PDO range. All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As it is a sterile single-use product, always check the integrity of the packaging before each procedure, store it in a cool, dry place protected from sunlight and respect the expiry date. For special B2B conditions, volume orders or enquiries about additional calibres, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Material

Polyglycolic acid (PGA) 100% absorbable by hydrolysis

Structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

USP size

0 (metric 3.5; approximate diameter 0.35-0.399 mm)

Needle size

DS 24 (24 mm), ⅜ circle

Tip type

Triangular reverse cutting (reverse cutting)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (minimum order 30 boxes)

Manufacturer reference

P112DS2410

Medida de aguja

DS 24

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture | ⅜ Circle Triangular Point Reverse Cutting Needle 24 mm (DS 24) | USP 0 (Metric 3.5) | Violet Fluted Thread 75 cm | Ref. P112DS2410 – Box of 12 units”

Your email address will not be published. Required fields are marked *