We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Fine Suture | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 4/0 (Metric 1.5) | Violet Non-Grooved Thread 70 cm | Box of 12 units | Ref. P118DS1940FN

Original price was: 55,30 €.Current price is: 36,90 €.

Absorbable multifilament PGA (polyglycolic acid) suture in Prime Fine quality mounted on a ⅜ circle needle with a reverse cutting triangular point of 19 mm (DS19). USP gauge 4/0 (metric 1.5), violet non-grooved thread of 70 cm coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Reference P118DS1940FN, box of 12 units and minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118DS1940FN

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture in Prime Fine quality, reference P118DS1940FN, is the professional reference solution for B2B supply to operating theatres, purchasing centres and healthcare distributors. It combines a 100% absorbable synthetic polymer with predictable clinical behaviour, exceptional handling and excellent knot security for tissue approximation, ligatures and general surgery.

Its ⅜ circle needle with 19 mm reverse cutting triangular point (DS19) in Fine version ensures firm, controlled penetration even in fine and non-compliant tissues, while the 70 cm violet non-grooved thread offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and non-reesterilizable.

2. Technical explanation of the product and procedure

Polyglycolic acid (PGA) is an absorbable synthetic polymer presented in a braided multifilament structure with a non-grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the saw effect, offers smooth sliding and guarantees excellent knot security even in fine gauges such as USP 4/0 (approximate diameter 0.15-0.199 mm).

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance metabolised by the body without causing significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical healing phase, while the tissue recovers its own resistance.

The ⅜ circle needle with 19 mm reverse cutting triangular point (triangular inverted / reverse cutting), Fine model, penetrates firm, fibrous and non-compliant tissues with controlled trauma and without tearing them, making it particularly suitable for skin closures, fascia, aponeurosis, ligatures and reduced surgical fields. The violet colour of the thread facilitates its tracking throughout the procedure. The product is supplied sterile by ethylene oxide and must not be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P118DS1940FN

Parameter Specification
Reference (SKU Cahnos) AMP118DS1940FN
Catalogue reference P118DS1940FN
Brand / Range PREMISUT (Prime quality, premium range)
Material 100 % absorbable polyglycolic acid (PGA), braided multifilament
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament, smooth finish
Gauge USP 4/0 (metric 1.5)
Approximate diameter 0.15 – 0.199 mm (USP/EP standard)
Thread colour Violet
Thread length 70 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size DS19 (19 mm), Fine model
Absorption mechanism Hydrolysis (60 – 90 days)
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)
Regulatory standard USP/EP

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60 – 90 days, by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
4/0 1.5 0.15 – 0.199 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most established medium-absorption synthetic absorbable in surgical practice (classic «Dexon» family). This Prime reference, with hydrolysis absorption of 60-90 days, tensile strength retention of 75/50/40 % at 2/3/4 weeks and a ⅜ circle needle with 19 mm reverse cutting triangular point (DS19 Fine), is comparable at category level (not interchangeable 1:1) with the following homologous lines from other manufacturers, verified against official sources (manufacturer catalogue and/or GUDID database):

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® — pure polyglycolic acid, coated braided multifilament C1049420 Comparable by category (not interchangeable 1:1) Safil USP 4/0 (EP 1.5), 70 cm, DS19 reverse cutting needle; colourless compared to the violet of this reference. It matches in material, gauge, needle and length; they differ in colour, each manufacturer’s own coating and commercial presentation (box of 36 units).
B. Braun (Aesculap) Novosyn® — polyglactin 910, coated braided multifilament C0069420 Comparable by category (not interchangeable 1:1) Novosyn USP 4/0 (1.5), 70 cm, DS19. The material differs: polyglactin 910 (copolymer 90% glycolide / 10% L-lactide, absorption 56-72 days) versus pure PGA with absorption of 60-90 days.
SMI (Surgical Materials Industries) Surgicryl® PGA — polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate 11151519U Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 4/0 (1.5), DS19 reverse cutting, 75 cm colourless. It matches in material, coating, gauge and needle; they differ in thread length (75 cm vs 70 cm), colour and commercial presentation.

At category level, homologous lines of coated braided PGA also include: DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon® / Dexon II® range. Ethicon Vicryl® / Vicryl® Plus (polyglactin 910) shares the multifilament behaviour and medium-absorption philosophy, but uses a different copolymer with absorption of 56-72 days, so it is not interchangeable 1:1 material to material.

There is no equivalence table validated by the manufacturer for this specific configuration (Prime multifilament PGA, ⅜ circle DS19 Fine reverse cutting needle, USP 4/0 gauge, 70 cm violet thread); consult the technical department of Cahnos before use in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (70 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: skin, subcutaneous tissue, mucous membranes, fascia and standard healing planes. The reverse cutting triangular point needle (DS19 Fine) is recommended when firm tissues need to be penetrated without tearing; the Fine version provides precise penetration in reduced surgical fields.

Reference Variant
AMP118DS1940FN PGA Prime, DS19 mm Fine needle, USP 4/0, violet, 70 cm (current product)
AMP128DS1940FN PGA Prime, same DS19 mm Fine needle, USP 4/0, colourless, 70 cm (maximum aesthetic discretion)
AMP111DS1940FN PGA Prime, DS19 mm Fine needle, USP 4/0, violet, 45 cm (shorter length)
AMP118DS2440 PGA Prime, DS24 mm needle, USP 4/0, violet, 70 cm (larger needle size)
P1L18DS1940FN PGLA Prime, same DS19 mm Fine needle, USP 4/0, violet, 70 cm (polyglactin 910, absorption 56-72 days)
AMP418DS1940FN PDO Prime, same DS19 mm Fine needle, USP 4/0, violet, 70 cm (monofilament, absorption 180-210 days)

For maximum visibility in the field, the violet version is the most suitable; if greater aesthetic discretion is preferred, the same configuration can be requested in a colourless version. If your protocol requires longer tensile support (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units, with a minimum order of 30 boxes. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.

Additional information

Material

100% absorbable polyglycolic acid (PGA), braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 4/0 (metric 1.5)

Thread diameter

0.15 – 0.199 mm (USP/EP standard)

Needle tip

Triangular with reverse cutting (reverse cutting)

Needle size

DS19 (19 mm) Fine model

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P118DS1940FN

Medida de aguja

DS 19

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Fine Suture | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 4/0 (Metric 1.5) | Violet Non-Grooved Thread 70 cm | Box of 12 units | Ref. P118DS1940FN”