Absorbable PGA Multifilament Suture Prime · 3/8 Circle Trocar Point Tapercut Needle 17 mm (DRT17) · USP 4/0 · Colourless · 70 cm · Box of 12 units · Ref. AMP128DRT1740

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament PGA Prime suture with ⅜ circle needle, cylindrical body and trocar point (Tapercut) of 17 mm, USP 4/0 gauge (metric 1.5), colourless thread of 70 cm and grooved finish. Predictable absorption by hydrolysis in 60–90 days and tensile strength retention of 75 % at 2 weeks. Sterile by ethylene oxide, minimal tissue reaction and indicated for tissue approximation, ligatures and general surgery. Presentation: box of 12 units with minimum order of 30 boxes. Ref. AMP128DRT1740.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP128DRT1740

Description

1. Product Presentation

The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range by PREMISUT is the reference choice for operating theatres, clinics and purchasing centres that need a high-performance sterile surgical thread, mounted on an atraumatic needle and ready to use. This reference combines an absorbable material with predictable clinical behaviour with a ⅜ circle needle, cylindrical body and trocar point (Tapercut) of 17 mm (DRT 17), which offers smooth and precise passage through tissues with minimal tissue trauma. Its USP 4/0 gauge and colourless finish guarantee minimal visual interference on the surgical field and comfortable handling for the surgeon. Professional presentation in a box of 12 units with a minimum order of 30 boxes, ideal for stock management in B2B conditions.

2. Technical explanation of the material and procedure

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and coated multifilament structure (grooved surface), which favours the sliding of the thread through tissue and the smooth seating of the knot. Absorption occurs by hydrolysis, a uniform process independent of tissue enzymes, which guarantees predictable reabsorption between 60 and 90 days with minimal tissue reaction. The coating of polycaprolactone and calcium stearate improves handleability and safety in knot tying, maintaining excellent strength during the critical healing period. The 17 mm (DRT 17) needle, with a cylindrical body and trocar point type Tapercut, combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them, reducing tissue trauma; this short arc geometry (⅜) is especially valued in reduced surgical fields. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Reference / SKU AMP128DRT1740
Brand / Range PREMISUT · Prime
Material 100 % polyglycolic acid (PGA) with coating of polycaprolactone and calcium stearate
Thread structure Multifilament braided coated (fluted)
USP / metric gauge 4/0 (metric 1.5)
Thread length 70 cm
Thread colour Colourless
Needle shape 3/8 circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 17 mm (DRT 17 Prime)
Sterilisation Ethylene oxide (EtO)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units · Minimum order 30 boxes

3.2. Absorption profile and tensile strength retention

Absorption type Hydrolysis
Total absorption 60–90 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 40 %
Knot tying Excellent security and handling

3.3. Size equivalence

USP size Approximate diameter Metric size
4/0 0.150 – 0.199 mm (USP standard) 1.5

Single-use, not re-sterilisable. Purchase format: price per box of 12 units, minimum order of 30 boxes.

4. Equivalences and Cross-References

Braided and coated polyglycolic acid (PGA) is the reference synthetic absorbable multifilament suture raw material on the market, comparable in chemical composition, hydrolysis absorption mechanism (60–90 days) and tensile strength retention with the main international braided PGA lines. Below are detailed confirmed technical cross-references against official catalogue sources:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Serag Wiessner SERAFIT (PGA multifilament, colourless or violet) 6O153210 Comparable by category (not interchangeable 1:1) Same PGA material, same DRT-17 needle (⅜ circle, trocar point), same USP 4/0 gauge (EP 1.5) and 70 cm; differences: violet colour (the manufacturer offers colourless in other references), presentation of 24 units and declared absorption profile ≈90 days. Code verified in official Serag Wiessner catalogue.
B. Braun Safil (coated braided PGA) C1049013 Comparable by category (not interchangeable 1:1) Same PGA polymer, USP 4/0 gauge, colourless thread of 70 cm; differences: HR17 needle of ½ circle and conical point (Taperpoint) versus the DRT17 needle of ⅜ circle with trocar point of this reference. Code verified in catalogues of authorised distributors and GUDID.

The indicated equivalences are indicative and are offered at category level; there is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the Cahnos catalogue, the violet thread variant of identical configuration corresponds to reference AMP118DRT1740, and the polyglactin 910 (PGLA) version with the same needle and gauge to reference P1L28DRT1740.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations in general, digestive, gynaecology and urology surgery, where minimal trauma and quality healing are sought. The ⅜ circle needle with trocar point (Tapercut) of 17 mm is the recommended choice for tissues of moderate consistency and reduced working fields; for soft and friable tissues, the conical point profile (Taperpoint) may be considered and, for tissues of greater consistency, longer needles. The colourless version minimises the visual interference of the thread on the field; if maximum visibility is preferred, the violet variant is available under reference AMP118DRT1740. For the same family with a 13 mm DRT needle, see variants AMP118DRT1350 (USP 5/0) and AMP118DRT1360 (USP 6/0), and for a ½ circle needle with trocar point of 17 mm in colourless, reference AMP128HRT1740. As it is sterile single-use material, check the integrity of the packaging before each procedure and respect the expiry date. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Material

100 % polyglycolic acid (PGA) with coating of polycaprolactone and calcium stearate

Thread structure

Multifilament braided coated (fluted)

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Needle size

17 mm (DRT 17 Prime)

Sterilisation

Ethylene oxide (EtO)

Presentation

Box of 12 units

Minimum order

30 boxes

Product line

Prime (PREMISUT)

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

DRT 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable, Absorbable medium (46–120 days)