Description
1. Commercial Introduction
The multifilament absorbable suture of polyglycolic acid (PGA) in Prime quality (ref. P121XHS1650 · SKU AMP121XHS1650) is the absorbable closure solution for operating theatres, general surgery departments, plastic and cosmetic surgery units and B2B purchasing centres that require a braided synthetic thread with predictable handling, high knot security and controlled absorption. This configuration combines a colourless strand of 45 cm in USP 5/0 gauge with a ½ circular needle with triangular point in precision reverse cutting of 16 mm with square body: the ideal format for tissue approximation, ligatures and precision work on skin, mucous membranes and subcutaneous tissue, with a careful aesthetic result. Sterile single-use product, presented in a box of 12 units in individual sachets with batch traceability.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer, spun into a non-grooved braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with excellent first-knot retention and minimal tissue reaction. Absorption occurs by physiological hydrolysis —a predictable process independent of the patient’s enzymatic activity— over a period of 60 to 90 days, maintaining the necessary structural integrity during the critical phase of wound healing.
The 16 mm XHS needle features a ½ circle curvature with a triangular precision reverse cutting point (long cutting edge, cosmetic profile) and a square body: the square body prevents rotation in the needle holder and improves gesture precision, while the cutting edge cleanly cuts firm tissues, generating a sharp and controlled passage. The colourless colour of the thread facilitates visualisation of the surgical field and offers maximum aesthetic discretion, which is why it is especially appreciated in plastic and cosmetic surgery.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P121XHS1650 (Prime range) |
| Reference Cahnos (SKU) | AMP121XHS1650 |
| Material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament, non-ribbed |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 5/0 (metric EP 1), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.10 – 0.149 mm |
| Thread length | 45 cm |
| Thread colour | Colourless (violet on demand) |
| Needle shape | ½ circle (1/2 circular) |
| Tip type | Triangular, precision reverse cutting (reverse extra cutting), square body |
| Needle size | XHS 16 mm, 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and general and cosmetic surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order 30 boxes |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
|---|---|
| Absorption type | Hydrolysis |
| Absorption time | 60 – 90 days |
| Tensile strength at 2 weeks | 75% of initial strength |
| Tensile strength at 3 weeks | 50% of initial strength |
| Tensile strength at 4 weeks | 40% of initial strength |
| Absorption rate | Predictable and uniform |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 5/0 (this product) | 1 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
3.4. Reference code decoding
The official reference P121XHS1650 breaks down as follows: P (Prime range) + 121 (45 cm thread) + XHS16 (½ circle needle with triangular precision reverse cutting point of 16 mm with square body) + 50 (USP 5/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.
4. Equivalences and Cross-References
Medium-absorption polyglycolic acid (PGA) is the most widely implanted braided absorbable suture family on the market, comparable at clinical category level with the medium support lines of major international manufacturers. There is no manufacturer-validated equivalence table cross-referencing this specific reference (PGA Prime, ½ circle XHS needle of 16 mm, triangular reverse cutting point, USP 5/0, colourless 45 cm thread) with codes from other brands; consult the technical department before use in tenders. The following rows correspond to references verified in public sources (official manufacturer catalogue, regulatory databases and authorised distribution) and are declared at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| DemeTECH | DemeSORB® PGA (coated glycolide homopolymer) | PGA185016F4P – USP 5/0, DFS-3 needle (⅜ circle, reverse cutting, 16 mm), 45 cm thread, violet | Comparable by category (not interchangeable 1:1) | They match in material (coated PGA), USP 5/0 gauge, needle size of 16 mm and thread length of 45 cm; they differ in curvature (⅜ vs ½ circle), point family (DFS-3 vs XHS with square body) and colour (violet vs colourless). |
| DemeTECH | DemeSORB® PGA (coated glycolide homopolymer) | PGA175013F13M – USP 5/0, DP-3 needle (⅜ circle, precision reverse cutting, 13 mm), 45 cm thread, colourless | Comparable by category (not interchangeable 1:1) | They match in material, USP 5/0 gauge, length of 45 cm and colourless colour; they differ in curvature (⅜ vs ½ circle) and needle size (13 mm vs 16 mm). |
| SMI (Surgical Materials Industries) | Surgicryl® PGA (polyglycolic acid) | 11101516U – USP 5/0, DS16 needle (⅜ circle, reverse cutting, 16 mm), 75 cm thread, colourless | Comparable by category (not interchangeable 1:1) | Same material (PGA), USP 5/0 gauge and needle size of 16 mm; they differ in curvature (⅜ vs ½ circle), point family (DS16 vs XHS with square body) and thread length (75 cm vs 45 cm). |
The VICRYL™ lines (Ethicon / Johnson & Johnson MedTech, polyglactin 910), Safil® (B. Braun / Aesculap, coated PGA) and Polysorb™ (Medtronic/Covidien) constitute homologous families of the segment in clinical indication and medium absorption profile; however, they differ in base polymer, coating, needle geometry and commercial presentations, so none should be substituted without prior technical validation. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 5/0 gauge (metric 1) is indicated for delicate and low-tension tissues: fine skin, mucous membranes, subcutaneous tissue and closures in cosmetic and aesthetic surgery, where a small-diameter thread with good initial resistance is required. The ½ circular 16 mm needle with triangular precision reverse cutting point and square body is especially recommended when a sharp and controlled passage is needed in firm tissues with reduced-size surgical fields, with excellent aesthetic outcome and stability in the needle holder.
| SKU | Variant |
|---|---|
| AMP121XHS1650 (P121XHS1650) | PGA Prime XHS16 – USP 5/0 colourless – 45 cm (this product) |
| AMP121XHS1640 (P121XHS1640) | PGA Prime XHS16 – USP 4/0 colourless – 45 cm (same needle, thicker gauge) |
| AMP121XNS1650 (P121XNS1650) | PGA Prime XNS16 – USP 5/0 undyed – 45 cm (⅜ circle, conventional precision cutting) |
| AMP121XDS1650 (P121XDS1650) | PGA Prime XDS16 – USP 5/0 undyed – 45 cm (⅜ circle, reverse cutting with square body) |
| P1L21XHS1650 | PGLA Polyglactin 910 Prime XHS16 – USP 5/0 undyed – 45 cm (same needle geometry, absorption 56–72 days) |
For maximum aesthetic discretion choose the undyed version; if you require greater visibility of the thread on the field, the same configuration can be requested in violet on demand. Sterile single-use product: check the integrity of the pouch and the expiry date before each procedure, keep the reference P121XHS1650 together with the batch number for traceability and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions, volume orders or hospital supply agreements, contact the technical-commercial team at Cahnos.