Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) is the reference synthetic resorbable solution for the professional who demands predictable behaviour, excellent initial tensile strength and great knot security. This presentation incorporates a ½ circle needle with cylindrical body and trocar point (tapercut) of 17 mm (HRT17), USP gauge 3/0 (metric 2) and a 70 cm violet fluted braided thread, ideal for tissue approximation, ligatures and general surgery.
Designed for operating theatre services, clinics and purchasing centres, it is supplied in a box of 12 units, sterile by ethylene oxide and ready to use in critical procedures. A proven-quality option with stable supply and B2B conditions for volume buyers.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the thread surface: it favours smooth passage through tissue, reduces the sawing effect, offers excellent handling and guarantees great knot security even in fine working gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction, with absorption completing between 60 and 90 days. The thread retains the necessary mechanical support during the critical phase of wound healing.
The HRT17 needle features a ½ circle curvature with cylindrical body and trocar point (tapercut geometry): a convergent triangular-section point that combines firm penetration in tissues of moderate tension or slightly fibrous tissues with minimal tissue tearing as the thread passes. The fluted violet colour improves thread visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 118HRT1730 (SKU AM118HRT1730)
| Parameter | Specification |
| Factory reference / SKU | 118HRT1730 · AM118HRT1730 |
| Quality / Range | Normal (standard range) |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 3/0 (metric 2), conforming to USP/EP |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Violet grooved |
| Thread length | 70 cm |
| Swaged | Single needle (1 needle per thread) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Tapercut (converging triangular cross-section) |
| Needle size | HRT17 (17 mm) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. For the exact configuration of this reference (HRT17 needle of ½ circle and trocar point of 17 mm, USP gauge 3/0, 70 cm violet thread), a catalogue correspondence verified against a regulated source has been located:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® — pure polyglycolic acid, braided and impregnated multifilament | SAFIL VIOLET 3/0 (2) 70CM HRT17 (M) · verified in GUDID/FDA | Comparable by category (not interchangeable 1:1) | It matches in material (100 % PGA), USP gauge 3/0 (EP 2), violet colour, 70 cm length, single ½ circle needle and HRT17 trocar point of 17 mm. The coating (Safil’s own impregnation versus polycaprolactone and calcium stearate) and the commercial presentation differ. Verify IFU and availability in the region before substituting. |
There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department before using in tendering. As homologous market families to be verified reference by reference in their official data sheet before substitution, the following lines are cited: 100 % coated braided PGA —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat PGA— and polyglactin 910 lines —Vicryl (Ethicon) and Polysorb (Medtronic)—, always checking USP gauge 3/0, needle size of 17 mm in ½ circle, trocar point, thread length of 70 cm and violet colour. The copolymer ranges of polyglactin 910 (PGLA) are chemically different from PGA homopolymer and must not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP gauge 3/0 (metric 2) offers an ideal balance between initial strength and handling for tissues of moderate tension: skin, subcutaneous tissue, mucous membranes, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The HRT17 ½ circle trocar point (tapercut) needle is the appropriate choice for firm or slightly fibrous tissues where clean, tear-free penetration is required; if the tissue is soft or friable, consider the conical point (HR) variant of the same PGA family.
| Reference | Variant of interest |
| AM118HRT1730 | Standard PGA, HRT17 trocar point needle, USP 3/0, violet, 70 cm (current product) |
| AMP118HRT1730 | PGA Prime, same HRT17 trocar point needle, USP 3/0, violet, 70 cm (premium range) |
| AM118HRT1740 | Standard PGA, HRT17, USP 4/0, violet, 70 cm (greater precision in fine tissues) |
| 1L18HRT1730 / P1L18HRT1730 | Polyglactin 910 (PGLA) HRT17, USP 3/0, violet, 70 cm (absorption 56-72 days) |
| AM118HR1730-2 | PGA double needle 2xHR17, USP 3/0, violet, 2×70 cm (continuous techniques with bidirectional anchoring) |
All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the thread with gloves so as not to alter its mechanical properties, and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews