Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture is the medium-duration synthetic resorbable solution required by general surgery, gynaecology, urology and major ambulatory surgery departments: a braided, flexible thread with a fully predictable absorption profile, ideal for approximating soft tissues, ligatures and closures in deep and superficial planes.
This presentation incorporates a ½-circle needle with cylindrical body and trocar point of 17 mm (HRT17), fluted violet thread of 70 cm and USP 4/0 gauge. Designed for operating theatres, clinics and purchasing centres, it is supplied in a box of 12 sterile units with batch traceability, consistent quality and B2B terms for volume buyers.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the thread surface: it promotes smooth passage through tissue, reduces the sawing effect, offers excellent handleability and guarantees great security in knot tying, even in fine working gauges such as USP 4/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance metabolised by the body without generating relevant tissue reaction, with absorption completing between 60 and 90 days. The thread retains the necessary mechanical support during the critical phase of wound healing, maintaining 75% of the initial tensile strength at 2 weeks, 50% at 3 and 40% at 4.
The HRT17 needle features a ½-circle curvature with cylindrical body and trocar point (Tapercut geometry): a convergent triangular-section point that combines firm penetration in tissues of moderate tension or slightly fibrous tissues with minimal tissue tearing as the strand passes. The fluted violet colour improves thread visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AM118HRT1740
| Parameter | Specification |
| Reference / SKU | AM118HRT1740 |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish |
| Gauge / size | USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet grooved |
| Thread length | 70 cm, with a single needle (1 needle per thread) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Tapercut (converging triangular cross-section) |
| Needle size | HRT17 (17 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units |
| Regulatory standard | Gauges in accordance with USP and European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable and controlled resorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric size | Approximate diameter |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a polycaprolactone and calcium stearate coating. For the exact configuration of this reference (HRT17 ½-circle trocar-point needle of 17 mm, USP 4/0 gauge, 70 cm violet thread), a catalogue correspondence verified against a regulated source (GUDID/FDA) has been located:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® — pure polyglycolic acid, braided and impregnated multifilament | SAFIL VIOLET 4/0 (1.5) 70CM HRT17 (M) · cat. C1048313 / G1048313 / X1048313 · verified in GUDID/FDA | Comparable by category (not interchangeable 1:1) | It matches in material (100% PGA), USP 4/0 gauge (EP 1.5), violet colour, 70 cm length, single ½-circle trocar-point HRT17 needle of 17 mm. The coating differs (Safil’s own impregnation versus polycaprolactone and calcium stearate) and the commercial presentation. Verify IFU and availability in the region before substituting. |
No equivalence table validated by the manufacturer against third-party brands exists for this specific configuration; consult the technical department before use in tenders. As homologous market families to be verified reference by reference in their official data sheet before substitution, the 100% braided coated PGA lines are cited —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat PGA— and the polyglactin 910 lines —Vicryl (Ethicon) and Polysorb (Medtronic)—, always checking USP 4/0 gauge, 17 mm needle size in ½ circle, trocar point, 70 cm thread length and violet colour. The polyglactin 910 copolymer ranges (PGLA) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department. Within the Cahnos catalogue, the variants with identical needle geometry, gauge and length are: AMP118HRT1740 (violet PGA Prime), AM128HRT1740 (standard undyed PGA), AMP128HRT1740 (undyed PGA Prime). The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP 4/0 gauge (metric 1.5) is ideal for fine tissues and low-to-medium tension: skin approximation, subcutaneous tissue, mucous membranes, microsurgery and ligation of small-calibre vessels. The HRT17 ½-circle trocar-point (Tapercut) needle is recommended for firm or slightly fibrous tissues where clean, tear-free penetration is required; if the tissue is soft or friable, consider the conical-point (HR) variant of the same PGA family.
| Reference (SKU) | Variant of interest |
| AM118HRT1740 | Standard PGA, HRT17 trocar-point needle, USP 4/0, violet, 70 cm (current product) |
| AMP118HRT1740 | PGA Prime, same HRT17 trocar-point needle, USP 4/0, violet, 70 cm (premium range) |
| AM128HRT1740 | Standard PGA, same HRT17 trocar-point needle, USP 4/0, undyed, 70 cm (direct colour equivalent) |
| AM118HRT1730 | Standard PGA, HRT17, USP 3/0, violet, 70 cm (greater strength in moderate-tension tissues) |
| 1L18HRT1740 / P1L18HRT1740 | Polyglactin 910 (PGLA) HRT17, USP 4/0, violet, 70 cm (absorption 56-72 days, different copolymer) |
| AM418HRT1740 | Polydioxanone (PDO/PDS) monofilament, HRT17, USP 4/0, violet, 70 cm (absorption 180-210 days) |
All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves to avoid altering its mechanical properties, and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.