We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) · ½ Circle Cylindrical Body Trocar Point (Tapercut) Needle HRT17 of 17 mm · USP Gauge 4/0 (Metric 1.5) · Violet Grooved Thread 70 cm · Box 12 units · Ref. AM118HRT1740

Original price was: 30,90 €.Current price is: 25,00 €.

Absorbable multifilament suture of 100 % polyglycolic acid (PGA) with an atraumatic needle of ½ circle, cylindrical body and trocar point (Tapercut) of 17 mm (HRT17). USP gauge 4/0 (metric 1.5), braided violet grooved thread of 70 cm, coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Ref. AM118HRT1740, presentation in a box of 12 units with B2B conditions for hospitals, clinics and purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM118HRT1740

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture is the medium-duration synthetic resorbable solution required by general surgery, gynaecology, urology and major ambulatory surgery departments: a braided, flexible thread with a fully predictable absorption profile, ideal for approximating soft tissues, ligatures and closures in deep and superficial planes.

This presentation incorporates a ½-circle needle with cylindrical body and trocar point of 17 mm (HRT17), fluted violet thread of 70 cm and USP 4/0 gauge. Designed for operating theatres, clinics and purchasing centres, it is supplied in a box of 12 sterile units with batch traceability, consistent quality and B2B terms for volume buyers.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the thread surface: it promotes smooth passage through tissue, reduces the sawing effect, offers excellent handleability and guarantees great security in knot tying, even in fine working gauges such as USP 4/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance metabolised by the body without generating relevant tissue reaction, with absorption completing between 60 and 90 days. The thread retains the necessary mechanical support during the critical phase of wound healing, maintaining 75% of the initial tensile strength at 2 weeks, 50% at 3 and 40% at 4.

The HRT17 needle features a ½-circle curvature with cylindrical body and trocar point (Tapercut geometry): a convergent triangular-section point that combines firm penetration in tissues of moderate tension or slightly fibrous tissues with minimal tissue tearing as the strand passes. The fluted violet colour improves thread visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference AM118HRT1740

Parameter Specification
Reference / SKU AM118HRT1740
Suture type Synthetic absorbable braided multifilament
Material 100 % absorbable polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish
Gauge / size USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.15 – 0.199 mm (indicative according to Pharmacopoeia)
Thread colour Violet grooved
Thread length 70 cm, with a single needle (1 needle per thread)
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Tapercut (converging triangular cross-section)
Needle size HRT17 (17 mm)
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units
Regulatory standard Gauges in accordance with USP and European Pharmacopoeia (EP)

3.2. Tensile strength retention profile after implantation

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable and controlled resorption rate.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric size Approximate diameter
4/0 (this product) 1.5 0.15 – 0.199 mm (indicative according to Pharmacopoeia)
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a polycaprolactone and calcium stearate coating. For the exact configuration of this reference (HRT17 ½-circle trocar-point needle of 17 mm, USP 4/0 gauge, 70 cm violet thread), a catalogue correspondence verified against a regulated source (GUDID/FDA) has been located:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® — pure polyglycolic acid, braided and impregnated multifilament SAFIL VIOLET 4/0 (1.5) 70CM HRT17 (M) · cat. C1048313 / G1048313 / X1048313 · verified in GUDID/FDA Comparable by category (not interchangeable 1:1) It matches in material (100% PGA), USP 4/0 gauge (EP 1.5), violet colour, 70 cm length, single ½-circle trocar-point HRT17 needle of 17 mm. The coating differs (Safil’s own impregnation versus polycaprolactone and calcium stearate) and the commercial presentation. Verify IFU and availability in the region before substituting.

No equivalence table validated by the manufacturer against third-party brands exists for this specific configuration; consult the technical department before use in tenders. As homologous market families to be verified reference by reference in their official data sheet before substitution, the 100% braided coated PGA lines are cited —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat PGA— and the polyglactin 910 lines —Vicryl (Ethicon) and Polysorb (Medtronic)—, always checking USP 4/0 gauge, 17 mm needle size in ½ circle, trocar point, 70 cm thread length and violet colour. The polyglactin 910 copolymer ranges (PGLA) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department. Within the Cahnos catalogue, the variants with identical needle geometry, gauge and length are: AMP118HRT1740 (violet PGA Prime), AM128HRT1740 (standard undyed PGA), AMP128HRT1740 (undyed PGA Prime). The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 4/0 gauge (metric 1.5) is ideal for fine tissues and low-to-medium tension: skin approximation, subcutaneous tissue, mucous membranes, microsurgery and ligation of small-calibre vessels. The HRT17 ½-circle trocar-point (Tapercut) needle is recommended for firm or slightly fibrous tissues where clean, tear-free penetration is required; if the tissue is soft or friable, consider the conical-point (HR) variant of the same PGA family.

Reference (SKU) Variant of interest
AM118HRT1740 Standard PGA, HRT17 trocar-point needle, USP 4/0, violet, 70 cm (current product)
AMP118HRT1740 PGA Prime, same HRT17 trocar-point needle, USP 4/0, violet, 70 cm (premium range)
AM128HRT1740 Standard PGA, same HRT17 trocar-point needle, USP 4/0, undyed, 70 cm (direct colour equivalent)
AM118HRT1730 Standard PGA, HRT17, USP 3/0, violet, 70 cm (greater strength in moderate-tension tissues)
1L18HRT1740 / P1L18HRT1740 Polyglactin 910 (PGLA) HRT17, USP 4/0, violet, 70 cm (absorption 56-72 days, different copolymer)
AM418HRT1740 Polydioxanone (PDO/PDS) monofilament, HRT17, USP 4/0, violet, 70 cm (absorption 180-210 days)

All references are supplied in a box of 12 units. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves to avoid altering its mechanical properties, and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.

Additional information

Material

100 % polyglycolic acid (PGA) braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 4/0 (metric 1.5)

Thread length

70 cm, 1 needle per suture

Thread colour

Violet grooved

Needle body

Cylindrical

Needle size

HRT17 · 17 mm

Sterilisation

Ethylene oxide (EtO), single-use

Presentation

Box of 12 units

Regulatory standard

Gauges in accordance with USP and European Pharmacopoeia (EP)

Medida de aguja

HRT 17

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) · ½ Circle Cylindrical Body Trocar Point (Tapercut) Needle HRT17 of 17 mm · USP Gauge 4/0 (Metric 1.5) · Violet Grooved Thread 70 cm · Box 12 units · Ref. AM118HRT1740”

Your email address will not be published. Required fields are marked *