Absorbable Multifilament PGA Prime Suture | 100% Polyglycolic Acid | ½ Circle Cylindrical Body Trocar Point (Tapercut) Needle HRT17 (17 mm) | USP 3/0 Gauge (Metric 2) | Fluted Violet Thread 70 cm | Ref. 118HRT1730 | Box of 12 units

Original price was: 41,48 €.Current price is: 32,60 €.

Absorbable multifilament PGA Prime suture with a ½ circle cylindrical body trocar point (tapercut) needle of 17 mm (HRT17). Gauge USP 3/0 (metric 2) and 70 cm of fluted violet thread, coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction, indicated for tissue approximation, ligation and general surgery. Ref. 118HRT1730 · SKU AMP118HRT1730 · box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118HRT1730

Description

1. Commercial Introduction

The Prime quality multifilament absorbable polyglycolic acid (PGA) suture is the professional choice for operating theatre services, purchasing centres and hospital distribution seeking a high-performance absorbable synthetic thread with a very competitive value for money in B2B procurement. This presentation incorporates a half-circle needle with a cylindrical body and trocar point (tapercut) of 17 mm (HRT17), USP 3/0 (metric 2) calibre and a 70 cm fluted violet thread, ideal for tissue approximation, ligatures and general surgery. Sterile medical device, single-use, ready to use, in a box of 12 units. Manufacturer reference 118HRT1730 · SKU Cahnos AMP118HRT1730.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the suture surface: it promotes smooth passage through tissue, reduces the sawing effect, offers excellent handling and guarantees high knot security even in fine working calibres such as USP 3/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance metabolised by the body without causing significant tissue reaction, with absorption completed within 60 to 90 days. The suture retains the necessary mechanical support during the critical phase of wound healing.

The HRT17 needle features a half-circle curvature with a cylindrical body and trocar point (tapercut geometry): a converging triangular-section point that combines firm penetration in tissues under moderate tension or slightly fibrous tissues with minimal tissue tearing as the thread passes through. The fluted violet colour improves suture visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference 118HRT1730 (SKU AMP118HRT1730)

Parameter Specification
Factory reference / SKU 118HRT1730 · AMP118HRT1730
Range / quality PGA Prime (premium quality)
Material 100 % synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge / size USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia
Approximate diameter 0.20 – 0.249 mm (indicative according to Pharmacopoeia)
Thread colour Fluted violet (colourless version available in the range)
Thread length 70 cm, 1 needle per suture
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Tapercut (converging triangular cross-section)
Needle size HRT17 (17 mm)
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units; minimum order of 30 boxes
Regulatory standard Gauges in accordance with USP and European Pharmacopoeia (EP)

3.2. Tensile strength retention profile after implantation

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

Complete absorption by hydrolysis within 60 to 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 (this product) 2 0.20 – 0.249 mm (indicative according to Pharmacopoeia)
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. For the exact configuration of this reference (HRT17 half-circle trocar-point needle of 17 mm, USP 3/0 calibre, 70 cm violet suture), a catalogue correspondence confirmed against a regulated source has been identified, not interchangeable 1:1:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Safil® — pure polyglycolic acid, coated braided multifilament SAFIL VIOLET 3/0 (2) 70CM HRT17 (M) · GUDID 04038653964444 Comparable by category (not interchangeable 1:1) It matches in material (100 % PGA), USP 3/0 (EP 2) calibre, violet colour, 70 cm length, half-circle shape and 17 mm HRT17 tapercut needle. The coating differs (glyconate/Safil’s own impregnation versus polycaprolactone and calcium stearate), as do the commercial presentation and the exact published retention profile. Code verified in the GUDID/FDA repertoire (0304025…) and in the official B. Braun catalogue.

There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department before use in tenders. As homologous market families to be verified reference by reference in their official datasheet before substitution, the following lines are cited: 100 % braided coated PGA —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat PGA (Internacional Farmacéutica)— and polyglactin 910 lines —Vicryl (Ethicon) and Polysorb (Medtronic)—, always checking USP 3/0 calibre, 17 mm needle size in half-circle, trocar point, 70 cm suture length and violet colour. The polyglactin 910 copolymer ranges (PGLA) are chemically different from PGA homopolymer and should not be treated as interchangeable 1:1 without validation from the pharmacy service or technical department. Likewise, the Monosyn range (B. Braun, glycolide/caprolactone copolymer monofilament) shares the HRT17 needle and calibre but is a monofilament of different composition and does not allow 1:1 crossover. The brands cited belong to their respective manufacturers and are mentioned only for comparative reference.

5. Selection tips and variants of interest

USP 3/0 (metric 2) calibre offers an ideal balance between initial strength and handling for tissues under moderate tension: skin, subcutaneous tissue, mucous membranes, fascia and soft tissue in general, as well as for ligating medium-calibre vessels. The HRT17 half-circle trocar-point (tapercut) needle is the appropriate choice for firm or slightly fibrous tissues requiring clean, tear-free penetration; if the tissue is soft or friable, consider the conical-point (HR) variant from the same PGA family.

Reference Variant of interest
AMP118HRT1730 PGA Prime, HRT17 trocar point needle, USP 3/0, violet, 70 cm (current product)
AM112HRT2620 Standard PGA, HRT26 trocar point needle, USP 2/0, violet, 75 cm (larger radius needle)
AMP112HRT2620 PGA Prime, same HRT26 needle, USP 2/0, violet, 75 cm (higher range)
AM112HRT2630 Standard PGA, HRT26, USP 3/0, violet, 75 cm (same gauge, longer needle)
AMP128HR2230 PGA Prime, HR22 conical point needle, USP 3/0, undyed, 70 cm (atraumatic point, undyed)
1L18HRT2620 Polyglactin 910 (PGLA) HRT26, USP 2/0, violet, 70 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the suture with gloves to avoid altering its mechanical properties, and keep the reference together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other calibres, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % synthetic absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

USP size

3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm (indicative according to Pharmacopoeia)

Thread colour

Violet grooved

Needle shape

½ circle (1/2 circular)

Needle body

Cylindrical

Needle tip

Tapercut (converging triangular cross-section)

Needle size

HRT17 (17 mm)

Sterilisation

Ethylene oxide (EtO); sterile, single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units; minimum order of 30 boxes

Regulatory standard

USP/EP (conforming to USP and European Pharmacopoeia gauges)

Manufacturer reference

118HRT1730

Medida de aguja

HRT 17

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)