Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture is the trusted choice of the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ½ circle needle with cylindrical body and 26 mm trocar point (tapercut) ensures clean penetration in tissues under moderate tension with contained trauma, while the 75 cm violet fluted braided thread offers optimal visibility over the surgical field. Synthetic, absorbable, sterile and single-use medical device, with excellent value for money for the B2B supply of operating theatres, clinics, purchasing groups and surgical supply distributors. Commercial presentation in a box of 12 units with a minimum order of 30 boxes.
2. Technical explanation
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration regularises the surface of the thread, favours sliding through tissue, reduces the sawing effect and guarantees firm, secure knot tying, even in fine-to-medium working calibres such as USP 3/0 (metric 2).
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without generating significant tissue reaction, completing between 60 and 90 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own strength.
The HRT 26 needle features a ½ circle curvature with cylindrical body and trocar point (tapercut geometry): a convergent triangular-section point that combines firm penetration in tissues under moderate tension or slightly fibrous tissues with minimal tissue tearing as the strand passes through. The violet colour improves visibility of the thread throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 112HRT2630 (SKU AM112HRT2630)
| Parameter | Specification |
| Factory reference / SKU | 112HRT2630 · AM112HRT2630 |
| Range / quality | Premisut (standard quality) |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | Fluted violet (colourless version available in the range) |
| Thread length | 75 cm, 1 needle per thread |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Tapercut (converging triangular cross-section) |
| Needle size | HRT 26 mm (26 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units; minimum order of 30 boxes |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis |
Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a totally predictable and controlled absorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric size | Approximate diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
The coated braided multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. Having verified the documentation of the main equivalent manufacturers, no official equivalence table from the manufacturer has been found for a 1:1 cross-reference with the exact configuration of this reference (HRT 26 mm tapercut needle, USP 3/0 calibre, 75 cm thread and violet colour); the reference cited below is a catalogue comparison confirmed against authorised distribution, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL (coated braided polyglactin 910), violet, USP 3/0, 75 cm, SH-2 Plus tapercut needle, 26 mm, ½ circle | W9114 | Comparable by category (not interchangeable 1:1) | Confirmed in reference catalogue and authorised distribution: USP 3/0 calibre, violet colour, 75 cm length, ½ circle shape, 26 mm needle size and tapercut point family all match; the polymer (polyglactin 910 vs 100 % PGA) and the absorption profile (56-72 days vs 60-90 days) differ. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous market families to be verified reference by reference in their official data sheet before substitution, the following 100 % coated braided PGA lines are cited —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Assucryl PGA (Assut) and the historical Dexon (limited availability)— and the polyglactin 910 lines —Vicryl (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 3/0 calibre, 26 mm needle size in ½ circle, trocar point, 75 cm thread length and violet colour. The polyglactin 910 (PGLA) copolymer ranges are chemically different from PGA homopolymer and should not be treated as interchangeable 1:1 without validation from the pharmacy service or technical department. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 3/0 calibre (metric 2) offers an ideal balance between initial strength and manageability for tissues under moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of small-calibre vessels. The ½ circle trocar point (tapercut) HRT 26 needle is the appropriate choice for firm or slightly fibrous tissues where clean, tear-free penetration is required; if the tissue is soft or friable, consider the conical point (HR) variant of the same PGA family.
| Reference | Variant of interest |
| AM112HRT2630 | Standard PGA, HRT26 trocar point needle, USP 3/0, violet, 75 cm (current product) |
| AMP112HRT2630 | PGA Prime, same HRT26 configuration, USP 3/0, violet, 75 cm (premium range, direct equivalent from the same manufacturer) |
| AM112HRT2620 | Same HRT26 needle, USP 2/0 calibre, violet, 75 cm (larger calibre) |
| AM112HR2630 | Standard PGA HR26 conical point, USP 3/0, violet, 75 cm (atraumatic point) |
| 1L18HRT2630 | Polyglactin 910 (PGLA) HRT26, USP 3/0, violet, 70 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves to avoid altering its mechanical properties, and keep the reference alongside the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews