We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Suture Absorbable Multifilament PGA (Polyglycolic Acid) – Needle ½ Circle Cylindrical Body Conical Point Taperpoint HR 45 mm – Gauge USP 2 (Metric 5) – Violet Fluted Thread 70 cm – Ref. 118HR4502 (Box 12 units)

Original price was: 34,90 €.Current price is: 27,40 €.

Absorbable multifilament suture 100 % polyglycolic acid (PGA) from the Premisut range, reference 118HR4502 (SKU AM118HR4502). It mounts a ½ circle needle with cylindrical body and Taperpoint conical point of 45 mm (HR 45), USP gauge 2 (metric 5) and violet fluted thread of 70 cm coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterile by ethylene oxide, single-use, minimal tissue reaction and optimal knot security. Indicated for tissue approximation, ligatures and general surgery. Presentation in box of 12 units; minimum order of 30 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 units por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM118HR4502

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture from the Premisut range, reference 118HR4502 (SKU AM118HR4502), is the reference surgical closure solution for hospitals, private clinics, general surgery operating theatres and purchasing centres seeking a high-performance synthetic absorbable thread with an excellent price-quality ratio in B2B procurement and tenders.

It incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 45 mm, USP 2 gauge and violet grooved thread of 70 cm: a combination designed for the approximation of soft tissues, deep planes, ligatures and general surgery. Each unit is supplied sterile and ready to use, in an individual sachet with batch traceability, in a box of 12 units.

2. Technical explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling, low memory and guarantees firm and secure knot tying, even in high working gauges such as USP 2.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction. The ½ circle needle with Taperpoint conical point penetrates by separating the fibres without cutting them, minimising trauma to soft and friable tissues. The grooved violet colour ensures optimal visibility on the surgical field. It is a single-use product, sterile by ethylene oxide and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics (Ref. AM118HR4502)

Parameter Specification
Reference (SKU Cahnos) AM118HR4502
Factory reference 118HR4502
Range / Quality Premisut – Normal quality
Thread material 100 % polyglycolic acid (PGA), synthetic absorbable
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2 (metric 5 – EP)
Thread colour Violet grooved
Thread length 70 cm (1 thread, 1 needle)
Needle shape ½ circle (approx. 180°)
Needle body Cylindrical
Needle tip Conical (Taperpoint), tapered and atraumatic
Needle size 45 mm (HR 45)
Absorption mechanism Hydrolysis
Absorption period 60 – 90 days
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 sterile units (individual pouches)
Minimum order 30 units
Regulatory standard Conforms to USP Pharmacopoeia / European Pharmacopoeia (EP) for synthetic absorbable sutures

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Total absorption 60 – 90 days, by hydrolysis

Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tying, in accordance with the USP/European Pharmacopoeia. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
1 4 0.40 – 0.499 mm
2 (this product) 5 0.50 – 0.599 mm

4. Equivalences and Cross-References

Braided coated multifilament polyglycolic acid (PGA) with medium absorption (60–90 days) is one of the most widely used synthetic absorbables in general surgery and ligatures. This reference —PGA homopolymer, ½ circle Taperpoint conical needle HR 45 mm, USP 2 gauge and 70 cm violet thread— shares polymer, coating and clinical profile with the homologous 100% PGA lines on the market: Safil® (B. Braun), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), AssuCryl® (Assut) and the historical Dexon®/Dexon II® range (Medtronic/Covidien).

The copolymeric polyglactin 910 (PGLA) ranges, such as Coated Vicryl® (Ethicon), Polysorb® (Medtronic) or Novosyn® (B. Braun), share the category of coated braided absorbable multifilament, but differ in chemical composition and absorption window (56–72 days versus 60–90 days): they are comparable at category level, not interchangeable 1:1 without validation from the pharmacy service or the technical department. No closed code from another brand has been found in official sources that matches field by field (USP 2 gauge + 45 mm conical needle + 70 cm violet thread + PGA homopolymer) with this exact configuration. There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (45 mm), ½ curvature, point family (conical/taperpoint), single needle attachment, thread length (70 cm) and colour. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 2 gauge (metric 5) is indicated for tissues requiring high initial resistance: deep planes, fascia, aponeurosis, high-tension closures and ligatures in general and digestive surgery. The ½ circle needle with 45 mm conical point is recommended for soft, friable or lax tissues, where the atraumatic point separates the fibres without cutting them; if the tissue is dense or fibrous, consider the trocar point (tapercut), and for very firm structures with clean cutting, the reverse cutting triangular point (HS).

Reference (SKU) Variant of interest
AM118HR4502 PGA USP 2, HR 45 mm conical needle, violet, 70 cm (current product)
AMP118HR4502 PGA Prime quality, same HR 45 mm needle, USP 2, violet, 70 cm (premium range)
AM113HR4502 PGA USP 2, HR 45 mm needle, violet, 90 cm (longer thread length)
AM118HR4002 PGA USP 2, HR 40 mm needle, violet, 70 cm (shorter needle)
AM118HR4802 PGA USP 2, HR 48 mm needle, violet, 70 cm (longer needle)
AM118HR4501 PGA USP 1, same HR 45 mm needle, violet, 70 cm (smaller gauge)
1L18HR4502 Polyglactin 910 USP 2, HR 45 mm needle, violet, 70 cm (absorption 56–72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 units. For longer force retention needs (180–210 days), the polydioxanone (PDO) family is the recommended alternative. As this is sterile single-use material, check the integrity of the packaging and the expiry date before each procedure, and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or confirmation of equivalences for tenders, contact our technical-commercial team.

Additional information

Manufacturer reference

118HR4502

Material

100 % polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5 – EP)

Thread colour

Violet grooved

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

45 mm (HR 45)

Swaged

1 needle per suture

Absorption mechanism

Hydrolysis

Strength retention

75 % (2 weeks), 50 % (3 weeks), 40 % (4 weeks)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 sterile units (individual pouches)

Minimum order

30 units

Regulatory standard

Conforms to USP / EP Pharmacopoeia

Medida de aguja

HR 45

Usp

2

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Suture Absorbable Multifilament PGA (Polyglycolic Acid) – Needle ½ Circle Cylindrical Body Conical Point Taperpoint HR 45 mm – Gauge USP 2 (Metric 5) – Violet Fluted Thread 70 cm – Ref. 118HR4502 (Box 12 units)”

Your email address will not be published. Required fields are marked *