Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture in Prime quality is the reference surgical closure solution for operating theatres, private clinics and purchasing centres that demand fully predictable behaviour, excellent tensile strength and great security in knot tying. This presentation in USP 2 gauge features a ½ circle needle, cylindrical body and conical Taperpoint tip of 45 mm (HR45), with a 70 cm violet grooved thread.
It is supplied sterile and ready to use, in a box of 12 units with batch traceability, in a B2B format oriented to hospital replenishment, tenders and public competitions. Reference AMP118HR4502.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable homopolymer presented in a braided and grooved multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a contained friction coefficient, which favours the sliding of the thread through the tissue, very smooth handling and a firm and secure knot, even in high-diameter gauges such as USP 2.
Absorption occurs by hydrolysis, a uniform mechanism independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days and minimal tissue reaction. During the first weeks of healing, the thread maintains the necessary tensile strength while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and conical tip (Taperpoint geometry) of 45 mm separates the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with controlled passage and minimal injury along the penetration path. The grooved violet colour guarantees optimal visibility over the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Reference (SKU) | AMP118HR4502 |
| Range / quality | PGA Prime |
| Suture type | Absorbable synthetic multifilament |
| Composition | 100 % polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved |
| Gauge | USP 2 (metric 5) |
| Thread diameter | 0.45 – 0.499 mm (indicative USP/EP standard) |
| Thread colour | Violet grooved |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | 45 mm (HR45), 1 needle per thread |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and general surgery.
4. Equivalences and Cross-References
Braided coated polyglycolic acid (PGA) is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic ‘Dexon’ type family). This Prime reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40% at 2/3/4 weeks, shares polymer, coating (polycaprolactone and calcium stearate) and clinical profile with the homologous PGA lines on the market: B. Braun Safil® (braided coated PGA), SMI Surgicryl® PGA, DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range. The polyglactin 910 (PGLA) ranges, such as Ethicon Vicryl® or Medtronic Polysorb®, share the absorbable multifilament category but differ in chemical composition and absorption profile (56–72 days).
There is no equivalence table validated by the manufacturer for this specific configuration (Prime multifilament PGA, ½ circle conical Taperpoint HR45 needle of 45 mm, USP 2 gauge, 70 cm violet thread) compared to the cited commercial houses; consult the technical department before using in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (45 mm), ½ curvature, tip family (conical), configuration (single needle), thread length (70 cm) and colour.
5. Selection tips and variants of interest
USP 2 gauge (metric 5) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscle planes, abdominal wall closures and ligatures of medium-large calibre vessels. The conical Taperpoint needle separates the fibres without cutting them, being the most atraumatic option for soft and friable tissues; if the plane to be sutured is firm and not very compliant, consider the trocar points (Tapercut) from the same range.
| Reference | Variant |
| AMP113HR4502 | PGA Prime USP 2, HR 45 mm needle, violet, 90 cm (same configuration with longer thread) |
| AM118HR4502 | Standard quality PGA, USP 2, HR 45 mm needle, violet, 70 cm (cost optimisation) |
| AMP118HR4002 | PGA Prime USP 2, HR 40 mm needle, violet, 70 cm (shorter needle length) |
| AMP118HR4802 | PGA Prime USP 2, HR 48 mm needle, violet, 70 cm (longer needle length) |
| AMP118HR4501 | PGA Prime USP 1, HR 45 mm needle, violet, 70 cm (smaller gauge) |
| P1L18HR4502 | PGLA Prime USP 2, HR 45 mm needle, violet, 70 cm (polyglactin 910, absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As this is sterile single-use material, check the integrity of the packaging and the expiry date before each procedure and keep the reference and batch for traceability in the operating theatre. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.