We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

PGA Prime Absorbable Multifilament Suture | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 13 mm | USP 3/0 · Violet · 70 cm | Ref. AMP118HR1330 · Box 12 units

Original price was: 49,90 €.Current price is: 36,95 €.

Absorbable multifilament polyglycolic acid (PGA) suture in Prime quality, mounted on a ½ circle atraumatic needle, cylindrical body and conical Taperpoint point of 13 mm (HR 13). USP gauge 3/0 (metric 2), fluted violet thread of 70 cm. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3, and 40 % at 4. Sterilised by ethylene oxide, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Manufacturer’s reference P118HR1330 (SKU AMP118HR1330), presentation in a box of 12 units with a minimum order of 30 boxes and B2B terms for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118HR1330

Description

1. Product Presentation

The multifilament absorbable suture of polyglycolic acid (PGA) in Prime quality from Cahnos is the reference synthetic absorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great knot security. This presentation incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 13 mm (HR 13), USP 3/0 gauge and violet fluted thread of 70 cm.

It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional format of a box of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order of 30 boxes).

2. Technical explanation of the material and procedure

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and fluted multifilament structure, which gives it great handleability, low memory, regular surface and smooth sliding through tissue. The coating of polycaprolactone and calcium stearate reduces friction and drag effect, facilitating precise knot placement.

Absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread maintains the necessary tensile strength (75% at 2 weeks, 50% at 3 and 40% at 4), just enough time for the tissue to recover its own strength.

The ½ circle needle, cylindrical body and conical point (Taperpoint geometry) of 13 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The fluted violet colour guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference AMP118HR1330

Characteristic Specification
Reference (SKU) AMP118HR1330
Factory reference P118HR1330
Quality / Brand Prime · Cahnos
Suture type Absorbable synthetic multifilament
Composition 100 % polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament, grooved
USP / metric gauge 3/0 (metric 2)
Thread colour Violet
Thread length 70 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical Taperpoint, atraumatic
Needle size 13 mm (HR 13)
Absorption mechanism Hydrolysis
Total absorption 60–90 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60–90 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Coated braided polyglycolic acid is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic family type ‘Dexon’). This Prime reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40% at 2/3/4 weeks, is comparable at category level (not interchangeable 1:1) with homologous PGA lines from other manufacturers that use the same polymer and a similar clinical profile. The verified correspondences against the official catalogue are detailed below:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
SMI (Belgium) Surgicryl® PGA (braided coated polyglycolic acid, violet) 11200117 – USP 3/0 (metric 2), 1/2 circle needle round body conical point HR 17 mm, 75 cm, violet (official SMI catalogue, revision 6) Comparable by category (not interchangeable 1:1) Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1%) and same absorption 60–90 days; they differ in needle size (17 mm vs 13 mm) and thread length (75 cm vs 70 cm)
SMI (Belgium) Surgicryl® PGA (braided coated polyglycolic acid, violet) 11150113 – USP 4/0 (metric 1.5), HR 13 mm needle, 75 cm, violet (SMI official catalogue, revision 6) Comparable by category (not interchangeable 1:1) Same PGA family and same needle geometry HR 13 mm (1/2 circle, conical point); they differ in gauge (4/0 vs 3/0) and thread length (75 cm vs 70 cm)

There is no equivalence table validated by the manufacturer for this reference; the indicated correspondences are functional comparisons verified against the official SMI catalogue (Rev. 6) and must be confirmed with the technical department before use in tendering or formal substitution of references. At category level, they are also homologous lines of coated braided PGA: B. Braun Safil®/Novosyn®, DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range; Ethicon Vicryl® (polyglactin 910) shares the needle geometry and multifilament behaviour, but presents a different absorption profile (56–72 days). In all cases, any substitution must be validated code by code verifying material, gauge, needle geometry (shape, body, point and size), thread length and presentation in the technical data sheet or IFU of each manufacturer.

5. Selection tips and variants of interest

The USP 3/0 gauge (metric 2) combines good initial tensile strength with a medium diameter, being suitable for the approximation of tissues with moderate tension, ligatures of medium-calibre structures and general surgery, where reliable support is required during the first weeks of healing. The ½ circle needle with Taperpoint conical point of 13 mm is the most atraumatic option for soft and friable tissues; if a greater penetration arc is required, 17 mm needles from the same family can be considered.

Variants from the same Cahnos catalogue:

  • AM118HR1330: same HR 13 mm configuration, USP 3/0, violet, 70 cm in standard quality (factory reference 118HR1330).
  • AMP118HR1320 / AMP118HR1340 / AMP118HR1310: same HR 13 mm needle in USP 2/0, 4/0 and 0 gauges, violet, 70 cm (same absorption 60–90 days).
  • AMP118HR1050: HR 10 mm needle in USP gauge 5/0, for finer tissues.
  • AMP118HR1730-2: double needle HR 17 mm in USP gauge 3/0, for continuous sutures with anchorage at both ends.
  • AMP418HR1330: monofilament alternative in polydioxanone (PDO) with the same HR 13 mm needle and gauge, for longer healing times (180–210 days).

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Manufacturer reference

P118HR1330

Suture type

Absorbable synthetic multifilament

Material

100% Polyglycolic Acid (PGA)

Coating

Polycaprolactone and calcium stearate

Thread structure

Braided multifilament, grooved

Metric gauge (EP)

2

Thread diameter

0.20 – 0.249 mm (USP/EP standard)

Needle body

Cylindrical

Needle tip

Taperpoint conical (atraumatic)

Needle size

13 mm (HR 13)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

USP/EP

Structure

Multifilament braided fluted

Gauge

USP 3/0 (metric 2)

Tensile retention

75% (2 weeks), 50% (3 weeks), 40% (4 weeks)

Use

Single-use, not re-sterilisable

Medida de aguja

HR 13

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “PGA Prime Absorbable Multifilament Suture | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 13 mm | USP 3/0 · Violet · 70 cm | Ref. AMP118HR1330 · Box 12 units”

Your email address will not be published. Required fields are marked *