Description
1. Commercial Introduction
The multifilament absorbable suture of polyglycolic acid (PGA), reference 118HR4001 (SKU AM118HR4001), is the reference surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres seeking a high-performance synthetic absorbable thread with an excellent quality-price ratio. Its ½ circle needle with cylindrical body and 40 mm Taperpoint conical tip penetrates soft tissues by separating the fibres without cutting them, which minimises trauma and makes it particularly suitable for tissue approximation, ligatures and general surgery. Each unit is supplied sterile, ready to use and with batch traceability, in a presentation of a box of 12 units.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling, low memory and guarantees firm and secure knot tying, even in medium-high diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e. by controlled degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, metabolised by the body with minimal tissue reaction. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, a profile ideal for tissues requiring wound support during 2 to 4 weeks of healing.
The ½ circle needle (approx. 180°) with cylindrical body and Taperpoint conical tip penetrates by separating the fibres without cutting them, minimising trauma in soft and friable tissues; the grooved violet colouration ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference 118HR4001
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AM118HR4001 · Manufacturer ref. 118HR4001 |
| Range / Quality | PREMISUT – Normal quality |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 1 (metric 4 – EP) |
| Thread colour | Grooved violet (also available undyed) |
| Thread length | 70 cm (1 thread, 1 needle) |
| Needle shape | ½ circle (1/2 circular, approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), tapered and atraumatic |
| Needle size | 40 mm (HR 40 profile), 1 needle per thread |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile unit) |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures |
3.2. Tensile strength retention profile after implantation
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60 – 90 days by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of braided synthetic absorbable sutures with medium absorption (60–90 days). Due to the polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile and tensile retention, it is comparable at category level (not interchangeable 1:1) with the following homologous configuration on the international market, verified in the manufacturer’s official catalogue and authorised distribution:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson) | Coated VICRYL (braided coated polyglactin 910, violet) | J331H | Comparable by category (not interchangeable 1:1) | USP 1, violet thread of 90 cm and CT-2 taper point needle of 40 mm in ½ circle; gauge, colour, curvature and conical tip family coincide. The polymer differs (PGLA 90/10 copolymer versus PGA homopolymer), thread length (90 cm versus 70 cm) and absorption window (56–72 days versus 60–90 days). Code verified in official catalogue and authorised distribution. |
Other homologous families of 100% braided coated PGA that must be verified field by field (material, USP gauge, needle size and radius, curvature, tip family, thread length and colour) before any formal substitution: B. Braun (Safil), SMI (Surgicryl PGA), DemeTECH (DemeSORB PGA), Medtronic/Covidien (Dexon) and the cylindrical ½ circle HR/TC needle series from European laboratories. The copolymeric poliglactin 910 ranges (Vicryl, Polysorb, Novosyn, Safil) are chemically different from PGA homopolymer and should not be treated as interchangeable 1:1 without validation from the pharmacy service or the technical department. There is no equivalence table validated by the manufacturer that cross-references this configuration reference by reference with closed codes from other commercial houses; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: fascia, aponeurosis, muscular planes, abdominal wall and moderate-high tension closures. The ½ circle Taperpoint conical tip needle separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt tip, while for fibrous and dense structures the trocar tip (Tapercut) is recommended and for firm tissues with clean cutting, the reverse cutting triangular tip (HS). Also verify the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated.
| Reference (SKU) | Variant of interest |
|---|---|
| AM118HR4001 (118HR4001) | PGA USP 1, conical needle HR 40 mm, violet, 70 cm (current product) |
| AMP118HR4001 (P118HR4001) | PGA Prime quality USP 1, same HR 40 mm needle, violet, 70 cm (premium range, same configuration) |
| AM113HR4001 (113HR4001) | PGA USP 1, same HR 40 mm needle, violet, 90 cm (longer thread length) |
| AM118HR4010 | PGA USP 0, same HR 40 mm needle, violet, 70 cm (finer gauge) |
| AM118HR4002 | PGA USP 2, same HR 40 mm needle, violet, 70 cm (larger gauge) |
| AM118HR4801 | PGA USP 1, conical needle HR 48 mm, violet, 70 cm (larger needle radius) |
| AM118HS4001 | PGA USP 1, reverse cutting triangular needle HS 40 mm, violet, 70 cm (firm tissues) |
| 1L18HR4001 | PGLA (polyglactin 910) USP 1, HR 40 mm needle, violet, 70 cm (absorption 56–72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 units. If the procedure requires longer wound support (180–210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalence validation for tenders, please contact our technical-commercial team.





Reviews
There are no reviews yet.