Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture in Prime Heavy quality is the reference choice in the operating theatre for hospitals, private clinics and purchasing centres looking for a high-performance synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle with cylindrical body and conical point (Taperpoint) of 45 mm (HR 45), USP 1 gauge and 75 cm violet fluted thread.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos. Its Prime Heavy design ensures superior performance in procedures requiring high safety and reliability: tissue approximation, ligatures, deep planes and general surgery.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is an absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, even in larger diameter gauges.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. The thread retains 75 % of its tensile strength at 2 weeks, 50 % at 3 and 40 % at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ½ circle needle with cylindrical body and conical point (Taperpoint) penetrates by separating the fibres without cutting them, which minimises trauma to soft tissues; the violet colouration ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AMP112HR4501H (manufacturer ref. 112HR4501H) |
| Range / Quality | PREMISUT, Prime Heavy quality |
| Material | 100% Polyglycolic acid (PGA) with polycaprolactone and calcium stearate coating |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet (also available colourless) |
| Gauge | USP 1 (metric 4), conforming to USP/EP Pharmacopoeia |
| Thread length | 75 cm (1 thread, 1 needle) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Tapered conical (Taperpoint) |
| Needle size | 45 mm (HR 45 Heavy Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60–90 days |
| Sterilisation | Ethylene oxide (EO), single-use, not for re-sterilisation |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60–90 days, by hydrolysis |
3.3. Presentation and ordering conditions
| Value | Value |
|---|---|
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of synthetic absorbable braided sutures with medium absorption. By polymer composition, absorption profile and tensile retention, it is comparable at category level with the polyglactin 910 and PGA lines on the international market.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet, USP 1, 70 cm, CT-1 needle (conical point) of 40 mm, ½ circle | J341H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon data sheet and authorised distribution: they match in USP 1 gauge, violet colour and ½ circle shape; they differ in polymer (polyglactin 910 vs 100 % PGA), thread length (70 cm vs 75 cm), needle size (40 mm vs 45 mm) and absorption interval (56-72 days vs 60-90 days). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous families on the market, to be verified reference by reference in their official data sheet before substitution, the following lines are cited: 100 % PGA braided coated —Safil (B. Braun), Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI)— and polyglactin 910 —Coated VICRYL / VICRYL Plus (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 1 gauge, 45 mm needle size in ½ circle, conical point, 75 cm thread length and violet colour. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues that withstand moderate-high tension: fascia, aponeurosis, muscular planes, abdominal wall and ligatures of medium-calibre vessels. The conical point (Taperpoint) separates the fibres without cutting them, ideal for soft tissues; if the tissue is very delicate, the most atraumatic option is the blunt point, while for fibrous and dense structures the trocar point is recommended. Verify the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area.
Within the PGA Prime Heavy family from the same manufacturer, interesting variants are offered: AMP112HR3001H (same quality and gauge with HR 30 mm needle for reduced fields), AMP112HR4801H (HR 48 mm needle for deeper planes) and AMP112HR4010H (USP 0 gauge for lower traction). If you prefer a polyglactin 910 alternative with an absorption window of 56–72 days, consult the PGLA family in the catalogue; for longer force retention (180–210 days), the polydioxanone (PDO) family is the recommended alternative.
As it is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. Consult our technical-commercial team for special volume conditions: minimum order of 30 units, with scheduled deliveries for hospitals, clinics and purchasing centres.





Reviews