Description
1. Commercial Introduction
The Absorbable Multifilament PGA Prime Suture from Cahnos is the choice of the professional who demands an absorbable thread with predictable behaviour, excellent handling and maximum security in knot tying. This configuration combines a braided strand of 100% synthetic polyglycolic acid (PGA), violet, non-grooved and 70 cm long, with a ½ circle needle with cylindrical body and Taperpoint conical point of 22 mm (HR22 profile) in VisiBlack finish: the ideal option for soft tissue approximation, ligatures and general surgery, with an excellent quality-price ratio for hospital replacement, purchasing centres and B2B tenders. Presentation in a box of 12 units in individual sterile sachets, with a minimum order of 30 boxes to guarantee the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% synthetic homopolymer absorbable by hydrolysis, spun into a braided multifilament structure with a non-grooved finish and coated with polycaprolactone and calcium stearate. This coating regularises the surface of the strand: it reduces friction when passing through tissues (less saw effect), improves sliding, minimises tissue reactivity and facilitates firm and secure knot tying even in fine gauges such as USP 4/0.
Its degradation profile is designed for short to medium duration healing: it retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, completing absorption by hydrolysis between 60 and 90 days, independently of the patient’s enzymatic activity. The HR22 needle has a ½ circle curvature (160°) with a cylindrical body and Taperpoint conical point: the round body passes through soft tissues atraumatically and the conical point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. The VisiBlack finish of the needle, together with the violet thread, guarantees optimal visibility on the surgical field even with difficult lighting or bleeding. Product sterile by ethylene oxide (EO), single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P118HR2240VB (SKU AMP118HR2240VB)
| Parameter | Specification |
| Factory reference | P118HR2240VB (official nomenclature PGA Prime VisiBlack line) |
| Reference Cahnos (SKU) | AMP118HR2240VB |
| Range / quality | Prime (premium range) |
| Thread material | 100% polyglycolic acid (PGA), synthetic absorbable homopolymer |
| Thread structure | Braided coated multifilament, non-grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.15 – 0.199 mm |
| Thread length | 70 cm (free end, without loop) |
| Thread colour | Violet (colourless version available in the range) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Tip type | Taperpoint conical (atraumatic), VisiBlack finish |
| Needle size | HR 22 (22 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets, batch traceability) |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; medical device with CE marking |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Complete absorption | 60 – 90 days by hydrolysis (predictable and uniform rate) |
Absorption range and retention values copied literally from the manufacturer’s documentation, without extending limits. It should not be confused with rapid absorption PGA (RAPID line, 40–45 days) or with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 5/0 | 1 | 0.10 – 0.149 mm |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The diameter of the strand complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits. Decoding of the official reference P118HR2240VB: P1 (Prime range) + 18 (violet thread of 70 cm) + HR22 (½ circle needle with cylindrical body and Taperpoint conical point of 22 mm) + 40 (USP 4/0 gauge) + VB (VisiBlack finish). Cahnos markets the official reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. There is no manufacturer-validated equivalence table that cross-references this specific reference (100% PGA, HR22 needle of 22 mm with VisiBlack conical point, USP 4/0 gauge, violet thread of 70 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | Safil® Violet – coated braided multifilament polyglycolic acid, violet colour, USP 4/0 (metric 1.5), 70 cm, ½ circle cylindrical needle | C1048040 (SAFIL VIOLET 4/0 (1.5) 70CM HR26 (M)) | Comparable by category (not interchangeable 1:1) | Code confirmed in official B. Braun catalogue: they match material (100% PGA), braided and coated multifilament structure, USP 4/0 gauge, violet colour and length of 70 cm. They differ in needle size (HR26 of 26 mm vs HR22 of 22 mm), needle nomenclature and type of commercial coating. Validate in technical data sheet/IFU before substituting in tenders. |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (polyglactin 910, braided, violet), CT-3 ½ circle needle of 22 mm with Taperpoint conical point, 70 cm | J327H – USP 3/0 | Comparable by category (not interchangeable 1:1) | They match ½ circle curvature, cylindrical needle of 22 mm with conical point and thread length of 70 cm; they differ in polymer (polyglactin 910 vs polyglycolic acid), gauge (USP 3/0 vs 4/0) and commercial presentation (box of 36 units vs 12 units). Code confirmed in authorised distribution catalogue; verify IFU before substituting. |
As homologous ranges of the 100% PGA braided coated medium absorption segment, to be verified reference by reference in their official data sheet before substitution, the following lines are cited: Dexon® / Dexon II® (Medtronic/Covidien), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), Atramat® (Resorba) and Assucryl® PGA (Assut Sutures). The copolymer ranges of polyglactin 910 (PGLA) —Coated VICRYL® (Ethicon), Safil® Quick / Novosyn® (B. Braun), Polysorb® (Medtronic)— are chemically different from PGA homopolymer (absorption 56–72 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or technical department. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no manufacturer-validated equivalence table cross-referencing this reference in its exact configuration (PGA Prime, ½ circle HR22 needle, 22 mm, conical VisiBlack point, USP 4/0 gauge, 70 cm violet thread) with other brands; consult the technical department at Cahnos before use in tenders. Within the same system, the PGA family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided the needle gauge and geometry are respected.
5. Selection tips and variants of interest
USP 4/0 (metric 1.5) is a very fine gauge, indicated for delicate, low-tension tissues: fine skin, mucosa, subcutaneous tissue, superficial planes and ligation of fine-calibre vessels, where minimal trauma and aesthetic scarring are sought. The HR22 ½-circle needle with Taperpoint conical point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option for medium fields and soft tissues where an atraumatic passage is required, without a broad cutting effect and with minimal bleeding. If you need to pass through firmer, denser tissues (skin, fascia), consider the trocar points (HRT) or reverse cutting points (HS) available in the same range. The VisiBlack finish is especially indicated when maximum needle contrast is required in deep or bleeding fields.
| Variant (SKU) | Description |
| AMP118HR2240VB (P118HR2240VB) | PGA Prime – HR22 VisiBlack – USP 4/0 violet – 70 cm (current product) |
| AMP118HR2640 (P118HR2640) | PGA Prime – HR26 taperpoint – USP 4/0 violet – 70 cm (larger radius needle) |
| AMP118HR2230VB | PGA Prime – HR22 VisiBlack – USP 3/0 violet – 70 cm (slightly larger gauge) |
| AMP112HR2040 (P112HR2040) | PGA Prime – HR20 taperpoint – USP 4/0 violet – 75 cm (shorter needle, longer thread) |
| AMP128HR2230 (P128HR2230) | PGA Prime – HR22 taperpoint – USP 3/0 undyed – 70 cm (maximum discretion) |
| AM112HR2040 (112HR2040) | Standard PGA – HR20 taperpoint – USP 4/0 violet – 75 cm (economical alternative) |
| AMP318HR2240-2VB | PGCL monofilament Prime VisiBlack – double HR22 needle – USP 4/0 violet – 70 cm (absorption 90–120 days) |
| P1L18HR2640 | PGLA Prime (polyglactin 910) – HR26 – USP 4/0 violet – 70 cm (absorption 56–72 days) |
If the procedure requires longer wound support, consider poliglecaprone PGCL (90–120 days) or polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA RAPID (40–45 days). Sterility and storage: sterile product by ethylene oxide and single-use; check the integrity of the pouch and the expiry date before each procedure, handle the strand with gloves to avoid altering its mechanical properties, keep the reference together with the batch number for traceability in the operating theatre, and store below 30 °C, protected from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalences with other commercial brands, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.