Description
The 100% polyglycolic acid (PGA) multifilament absorbable suture from the PREMISUT range, reference 112HR3030, is the surgical closure solution your centre needs for general surgery procedures that require controlled absorption, excellent handling and impeccable knot security. It combines a ½ circle needle with cylindrical body and 30 mm taperpoint conical tip (HR30), a 75 cm violet braided grooved thread in USP 3/0 gauge and a B2B presentation in a box of 12 units, designed for the supply of operating theatres, purchasing centres and tenders. A synthetic, sterile, single-use medical device with a very competitive price-quality ratio for the continuous supply of your centre.
Technical product explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the thread, reduces friction when passing through tissues, improves sliding and guarantees firm and secure knot tying even in fine-to-medium working gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed between 60 and 90 days: the thread maintains tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own strength. The HR30 ½ circle needle with cylindrical body and taperpoint conical tip penetrates by separating the fibres without a cutting effect, which makes it especially atraumatic for soft and friable tissues, ligatures and tissue approximation in general surgery. The violet colour guarantees optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and non-reesterilisable.
Technical specifications
Technical data sheet for reference AM112HR3030
| Reference (SKU Cahnos) | AM112HR3030 |
| Factory reference | 112HR3030 (PREMISUT range, Normal quality) |
| Thread material | 100% polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread colour | Violet (grooved); colourless available on request |
| Thread length | 75 cm (1 needle per suture) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Needle tip | Conical taperpoint, atraumatic |
| Needle size | HR 30 (30 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying. Absorption range and retention values copied literally from the manufacturer’s documentation, without extending limits.
Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The thread diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
Equivalences and cross-references
Polyglycolic acid (PGA) is the most well-established medium-duration braided multifilament absorbable on the market and shares an absorption profile (60–90 days), coated braided structure and clinical behaviour with homologous families in the sector. There is no manufacturer-validated equivalence table that cross-references this specific product (100% PGA, HR30 needle with 30 mm conical tip, USP 3/0, violet, 75 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (braided coated polyglactin 910, violet) | J316H – USP 3/0, SH needle 26 mm, ½ circle, conical point, 70 cm | Comparable by category (not interchangeable 1:1) | Code verified in Ethicon’s official catalogue and authorised distribution: USP 3/0 gauge, ½ circle curvature, conical needle and violet colour match. Differences: polymer (polyglactin 910 vs 100% PGA), needle size (SH 26 mm vs HR30 30 mm), absorption profile (56–72 days vs 60–90 days), thread length (70 cm vs 75 cm) and presentation. |
| SMI (Surgical Materials Industries) | Surgicryl® PGA – polyglycolic acid braided multifilament coated with polycaprolactone and calcium stearate | SM1130 0130 (HR30 mm, taperpoint conical tip, ½ circle, USP 2/0) | Comparable by category (not interchangeable 1:1) | HR30 / taperpoint conical tip configuration confirmed in SMI authorised distribution: material (coated 100% PGA), ½ circle curvature and 30 mm needle size match. The gauge differs (USP 2/0 vs USP 3/0 of the analysed product); verify gauge, colour and thread length in the official datasheet before substituting. |
Homologous ranges in the medium-absorption braided PGA segment include Dexon II (Medtronic/Covidien), DemeSORB PGA (DemeTECH) and Atramat (Resorba), as well as the polyglactin 910 lines Coated VICRYL® / VICRYL® Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Assucryl 910 (Assut Sutures), comparable by category by material and absorption profile; for the exact combination USP 3/0 / HR 30 mm conical tip needle / 75 cm in violet, their specific codes must be confirmed with the manufacturer before any substitution, verifying material, gauge, curvature, needle type and size, thread length, colour and configuration. This geometry (HR30, USP 3/0, 75 cm) is fully interchangeable only within the PREMISUT system itself from Cahnos. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
Selection tips and variants of interest
The USP 3/0 gauge (metric 2) is one of the most in demand in general surgery: it is indicated for subcutaneous tissue, soft tissue approximation, superficial fascia and ligation of fine-to-medium calibre vessels, with reliable healing support during the first 2–3 weeks. The HR30 ½ circle needle with taperpoint conical tip is atraumatic and ideal for soft and delicate tissues; if you need to penetrate firmer and denser tissues (skin, fascia, aponeurosis), consider the reverse cutting (HS) or trocar (HRT) points available in the same range, and if you prefer maximum atraumatic performance, the blunt point (HRN).
| Variant / Reference | Description |
| AM112HR3030 (112HR3030) | Standard PGA – HR30 conical tip – USP 3/0 violet – 75 cm (this product) |
| AMP112HR3030 (P112HR3030) | PGA Prime – HR30 conical tip – USP 3/0 violet – 75 cm (same geometry, Prime quality) |
| AM112HR3020 | PGA – HR30 conical tip – USP 2/0 violet – 75 cm (larger gauge) |
| AM112HR3010 | PGA – HR30 conical tip – USP 0 violet – 75 cm (larger gauge and traction) |
| AM112HR2030 | PGA – HR20 conical tip – USP 3/0 violet – 75 cm (shorter needle, superficial planes) |
| AM112HRN3130 | PGA – HRN31 blunt tip – USP 3/0 violet – 75 cm (maximum atraumatic performance) |
| 1L12HR3030 | PGLA polyglactin 910 – HR30 conical tip – USP 3/0 violet – 75 cm (absorption 56–72 days) |
The violet colour offers maximum visibility in the surgical field; if aesthetic discretion is required in superficial areas, request the same configuration in colourless thread. If longer strength retention is needed (180–210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For special B2B terms based on volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews