Description
1. Introduction
The absorbable multifilament PGA Prime Heavy suture is the reference choice in the operating theatre for hospitals, private clinics and purchasing groups seeking a high-performance synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle with a cylindrical body and taper point (Taperpoint) of 48 mm (HR 48), USP 2 gauge and a violet grooved thread of 75 cm.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos. Its Prime Heavy design ensures superior performance in procedures requiring high safety and reliability: tissue approximation, ligatures, deep planes and general surgery.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, even in larger diameter gauges such as USP 2.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ½ circle needle with cylindrical body and taper point (Taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to soft tissues; the violet colouring ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet
| Characteristic | Specification |
| Reference (SKU) | AMP112HR4802H (manufacturer ref. P112HR4802H) |
| Range / Quality | PREMISUT, Prime Heavy quality |
| Material | 100% Polyglycolic acid (PGA) with polycaprolactone and calcium stearate coating |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet (also available colourless) |
| Gauge | USP 2 (metric 5) |
| Thread length | 75 cm (1 strand) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 48 mm (HR 48 Heavy Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60–90 days |
| Sterilisation | Ethylene oxide (EO), single-use, not for re-sterilisation |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60–90 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of synthetic braided absorbable sutures with medium absorption. By polymer composition, absorption profile and tensile retention, it is comparable at category level (not 1:1 interchangeable) with the polyglactin 910 and PGA lines on the international market: Ethicon (Johnson & Johnson) with its Coated VICRYL range (coated braided polyglactin 910, violet; differs in copolymer material PGLA 90/10 versus PGA homopolymer and in absorption window 56–72 days versus 60–90 days), B. Braun with Safil (violet braided PGLA), Medtronic/Covidien with Polysorb, SMI with Surgicryl, Assut with Assucryl 910 and Laboratorio Aragó (HR/TC needle series of cylindrical ½ circle). There is no equivalence table validated by the manufacturer that cross-references these brands; the lines cited are provided as a functional category comparison and must be verified field by field (gauge, thread length, needle radius and coating) before any formal substitution in tenders.
Within the same manufacturer and PREMISUT family, the verified references with equivalent or very similar configuration are:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| PREMISUT (Cahnos) | PGA Prime Heavy USP 2, HR 48 mm needle, violet, 75 cm | P112HR4802H | Exact reference equivalence (same manufacturer) | Official manufacturer reference for this same configuration; the distributor SKU AMP112HR4802H corresponds directly to it. |
| PREMISUT (Cahnos) | PGA Heavy USP 2 (Normal quality), HR 48 mm needle, violet, 75 cm | AM112HR4802H | Exact reference equivalence (same manufacturer) | Same HR 48 mm needle, same gauge, colour and length; differs only in quality (Normal versus Prime Heavy). |
| PREMISUT (Cahnos) | PGA Prime Heavy USP 1, HR 48 mm needle, violet, 75 cm | AMP112HR4801H | Comparable by category (not interchangeable 1:1) | Same needle and length; smaller gauge (USP 1) for areas of lower traction. |
| PREMISUT (Cahnos) | PGA Prime Heavy USP 2, HR 40 mm needle, violet, 75 cm | AMP112HR4002H | Comparable by category (not interchangeable 1:1) | Same gauge and quality with HR 40 mm needle (smaller radius), for surgical fields with more limited access. |
For a formal substitution of references in protocol or tender, consult our technical-commercial department.
5. Selection tips and variants of interest
USP 2 gauge (metric 5) is indicated for tissues requiring greater initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The taper point (Taperpoint) separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point, while for fibrous and dense structures the trocar point is recommended.
Check the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated. Within the PGA Prime family from Cahnos, variants are offered in gauge 2/0 (AMP112HR4820), USP 1 (AMP112HR4801H) and HR 40 mm radius (AMP112HR4002H); if you prefer a polyglactin 910 alternative with an absorption window of 56–72 days, consult references P1L12HR4002H and 1L12HR4002H. For longer force retention needs (180–210 days), the polydioxanone (PDO) family is the recommended alternative.
As it is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. Consult our technical-commercial team for special volume conditions: minimum order of 30 units, with scheduled deliveries for hospitals, clinics and purchasing groups.





Reviews