Description
1. Commercial Introduction
The PGA Prime Heavy multifilament absorbable suture, reference AMP112HR4010H, is the reference surgical closure solution for operating theatres, general surgery departments, private clinics and B2B purchasing centres that demand a high-performance absorbable synthetic thread with an excellent quality-price ratio. This presentation combines a 1/2 circle needle with cylindrical body and Taperpoint conical point of 40 mm in reinforced heavy version, USP size 0 and violet grooved thread of 75 cm.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos. Its Prime Heavy design ensures superior performance in procedures that demand high safety and reliability: tissue approximation, ligatures, deep planes and general surgery. Presentation in box of 12 units with minimum order of 30 units.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, reduces the sawing effect, offers very smooth handling and guarantees firm and secure knot tying, even in medium-diameter sizes such as USP 0.
Absorption occurs by hydrolysis —degradation of the polymer in contact with organic fluids— over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The 1/2 circle needle with cylindrical body and Taperpoint conical point penetrates by separating the fibres without cutting them, which minimises trauma to soft tissues; the violet grooved colouring ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP112HR4010H
| Characteristic | Specification |
| Reference (SKU Cahnos) | AMP112HR4010H (manufacturer ref. 112HR4010H) |
| Range / Quality | Prime Heavy (premium range with reinforced needle) |
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (also available colourless) |
| Thread length | 75 cm, 1 needle per thread |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint (tapered, atraumatic) |
| Needle size | HR 40 heavy (40 mm) |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 sterile units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60 – 90 days (hydrolysis) |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric size | Approximate diameter |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
3.4. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market. The following homologous configuration of close reference has been verified in public sources (authorised distribution and official catalogue data sheets) (USP size 0, violet braided thread with 1/2 circle needle and conical point):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet, USP 0, thread 70 cm, CT-2 taper point needle of 26 mm, 1/2 circle | J334H | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: USP size 0, violet colour, braided structure, 1/2 circle curvature and atraumatic conical point coincide; the polymer (polyglactin 910 vs 100% PGA), needle size (26 mm vs 40 mm), thread length (70 cm vs 75 cm) and absorption interval (56-72 days vs 60-90 days) differ. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous families of 100% braided coated PGA to be verified reference by reference in their official data sheet before substitution, the Safil® (B. Braun), Dexon II (Medtronic/Covidien), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH) and Atramat (Laboratorio Aragó) lines are cited, always checking USP size 0, 1/2 circle curvature, 40 mm conical point, 75 cm thread length and violet colour. The copolymeric polyglactin 910 ranges (Vicryl®, Polysorb®, Novosyn®) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or technical department.
5. Selection tips and variants of interest
USP size 0 (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscular planes, soft tissue approximation and ligation of medium-calibre vessels, with an excellent balance between initial resistance and predictable absorption during 2 to 4 weeks of healing. The 1/2 circle Taperpoint conical point needle separates the fibres without cutting them, ideal for soft tissues; if the tissue is very delicate, a blunt point is recommended, while for fibrous structures a trocar point is considered.
| Reference | Variant |
| AMP112HR4010H | PGA Prime Heavy USP 0, HR40 Taperpoint needle, violet, 75 cm (current product) |
| AM112HR4010H | PGA Heavy Normal quality USP 0, same HR40 needle, violet, 75 cm (same assembly, standard range) |
| AMP112HR4001H | PGA Prime Heavy USP 1, same HR40 needle, violet, 75 cm (larger size) |
| AMP112HR4002H | PGA Prime Heavy USP 2, same HR40 needle, violet, 75 cm (higher tension) |
| AMP112HR3010H | PGA Prime Heavy USP 0, HR30 conical needle, violet, 75 cm (shorter needle) |
| AMP112HR4801H | PGA Prime Heavy USP 1, HR48 conical needle, violet, 75 cm (larger needle radius) |
| AMP112HRN4010 | PGA Prime USP 0, blunt point HRN 40 mm, violet, 75 cm (more atraumatic) |
| AMP412HR4010 | PDO Prime USP 0, conical needle HR 40 mm, violet, 75 cm (absorption 180-210 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 units. If you need a longer force retention (180-210 days), consider the polydioxanone (PDO) family. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, and keep the reference together with the batch number for traceability in the operating theatre. For B2B volume conditions or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews