We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture Prime | 1/2 Circle Cylindrical Needle Taperpoint Conical Point HR 48 mm | USP Gauge 3/0 (Metric 2) | Violet Thread 70 cm | Ref. P118HR4830 · Box of 12 units

Original price was: 34,57 €.Current price is: 24,50 €.

Multifilament absorbable suture of polyglycolic acid (PGA) in Prime quality, reference P118HR4830 (SKU AMP118HR4830), with a ½-circle needle with cylindrical body and Taperpoint conical point, 48 mm (HR 48), USP gauge 3/0 (metric 2) and a highly visible ribbed violet thread of 70 cm. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for soft tissue approximation, ligatures and general surgery. Presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP118HR4830

Description

1. Commercial Introduction

At Cahnos we offer the absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality from the Premisut range, reference P118HR4830 (SKU AMP118HR4830), a high-end professional solution for B2B supply to operating theatres, clinics and purchasing groups. This presentation combines a ½ circle needle with cylindrical body and conical point of 48 mm (HR 48), USP 3/0 (metric 2) gauge and a violet 70 cm thread with high visibility on the surgical field.

It is the ideal choice for approximating soft tissues, ligatures and general surgery, with predictable absorption by hydrolysis that avoids thread removal, reliable mechanical support during the first weeks of healing and special B2B ordering conditions for hospitals and volume buyers. It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units.

2. Technical explanation of the material and procedure

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer, structured as a braided multifilament coated with polycaprolactone and calcium stearate. This combination ensures smooth passage through tissue, low thread memory, non-grooved surface and firm, secure knot seating, even in fine gauges such as USP 3/0 (metric 2).

Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable interval of 60 to 90 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks), while the tissue recovers its own strength.

The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 48 mm passes through tissue separating the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with precise penetration and minimal trauma along the path, ideal for deep suturing and general surgery. The violet colour ensures optimal visibility throughout the procedure. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P118HR4830

Characteristic Specification
Reference (SKU) AMP118HR4830
Catalogue reference P118HR4830
Brand / Quality Premisut – Prime
Material 100 % synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament, non-grooved surface
Coating Polycaprolactone and calcium stearate
USP / metric gauge USP 3/0 (metric 2)
Approximate diameter 0.20 – 0.249 mm (indicative according to Pharmacopoeia)
Thread length 70 cm
Thread colour Violet
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (Taperpoint), atraumatic
Needle size 48 mm (HR 48 Prime)
Absorption mechanism Hydrolysis
Total absorption 60 – 90 days
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes
Regulatory standard USP/EP

3.2. Tensile strength retention and absorption profile

Period Tensile strength retention
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Braided and coated multifilament polyglycolic acid (PGA) is one of the most established medium-absorption synthetic absorbables on the market (classic ‘Dexon’ type family). This Prime reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40% at 2/3/4 weeks and a ½ circle Taperpoint conical point needle of 48 mm, is comparable at category level (not 1:1 interchangeable) with the following homologous line verified against an official source:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
SMI (Belgium) Surgicryl® PGA – round body Taperpoint conical point 11300148 (USP 3/0, 1/2 circle needle HR 48 mm, 75 cm, violet, box of 12) Comparable by category (not interchangeable 1:1) Same 100% braided PGA coated with polycaprolactone and calcium stearate, same USP 3/0 gauge, same violet colour, same HR 48 mm needle geometry and 60–90 day absorption; the strand length differs (75 cm vs 70 cm). Verified in official SMI catalogue (Rev. 10).

At category level, homologous lines of braided coated PGA without verifiable code in public sources for this exact HR 48 mm needle configuration also include: AssuCryl (Assut Sutures), Petcryl (Dolphin Sutures), DemeSORB® PGA (DemeTECH) and the historical Dexon® / Dexon II® series (Medtronic). In the polyglactin 910 (PGLA) segment, a material from the same clinical family but of different composition, are Coated Vicryl® (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Vitacryl (DemeTECH). Within the Cahnos catalogue, the reference with the same needle geometry (HR 48 mm, USP 3/0, violet, 70 cm) in polyglactin 910 is P1L18HR4830 (absorption 56–72 days).

There is no manufacturer-validated equivalence table that cross-references this specific configuration (½ circle conical point HR 48 mm needle, USP 3/0 gauge, violet, 70 cm) with exact codes from other commercial houses: the identified matches must be treated as functional category comparisons and not as 1:1 interchangeable without technical validation. Consult the technical-commercial department of Cahnos before using this information in tenders or in the direct substitution of references. The cited brands belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

Select the gauge according to the tissue and the tension the suture must withstand: USP 3/0 (metric 2) gauge is very versatile and is indicated for skin, subcutaneous tissue, mucosa, fascia and soft tissues with moderate tension in general surgery and ligatures. The ½ circle needle with 48 mm conical point (HR 48) is especially suitable for deep sutures and areas of limited access where atraumatic penetration in delicate tissues is prioritised.

Reference Variant of interest
P1L18HR4830 PGLA Prime, same 1/2 circle HR 48 mm needle, USP 3/0, violet, 70 cm (absorption 56–72 days)
AM118HR4830 PGA Normal quality, same HR 48 mm needle, USP 3/0, violet, 70 cm (same geometry, standard quality)
AMP118HR4030 PGA Prime, 1/2 circle HR 40 mm needle, USP 3/0, violet, 70 cm (smaller needle radius)
AMP118HR4801 / AMP118HR4802 PGA Prime, HR 48 mm needle, violet, 70 cm, in USP 1 and USP 2 gauges (higher strength)
AMP118GR4830 PGA Prime, straight GR 48 mm needle, USP 3/0, violet, 70 cm (manual surface suturing)

All references are supplied in boxes of 12 units with a minimum order of 30 boxes. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders and hospital supply agreements, contact the technical-commercial team at Cahnos.

Additional information

Product line

Premisut – Prime

Material

100 % synthetic absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament, non-grooved surface

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm (indicative according to Pharmacopoeia)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint), atraumatic

Needle size

48 mm (HR 48 Prime)

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Tissue reaction

Minimal

Indications

Approximation of soft tissues, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

USP/EP

Medida de aguja

HR 48

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture Prime | 1/2 Circle Cylindrical Needle Taperpoint Conical Point HR 48 mm | USP Gauge 3/0 (Metric 2) | Violet Thread 70 cm | Ref. P118HR4830 · Box of 12 units”

Your email address will not be published. Required fields are marked *