We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture Prime | ½ Circle Cylindrical Body Trocar Point (Tapercut) Needle HRT 26 mm | USP Gauge 3/0 (Metric 2) | Fluted Violet Thread 75 cm | Ref. AMP112HRT2630 | Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of 100 % polyglycolic acid (PGA) in the Prime range, mounted on a ½ circle needle with cylindrical body and trocar point (tapercut) of 26 mm (HRT 26), fluted violet thread of 75 cm and USP gauge 3/0 (metric 2). Coated with polycaprolactone and calcium stearate, it offers smooth sliding, firm knot tying and predictable hydrolysis absorption in 60-90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterilised by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Supplied in a box of 12 units with a minimum order of 30 boxes. Ref. AMP112HRT2630.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP112HRT2630

Description

1. Product Presentation

The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference AMP112HRT2630, is the surgical closure solution your centre needs for general surgery, gynaecology and urology procedures that require controlled reabsorption, excellent handling and impeccable knot security. It combines a ½-circle cylindrical body needle with a 26 mm trocar (tapercut) point with a 75 cm violet braided fluted thread in USP 3/0 gauge.

It is a synthetic, absorbable, sterile, single-use medical device with an excellent price-quality ratio for B2B supply to operating theatres, clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes.

2. Technical explanation

Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread glide and facilitates firm, secure knotting, with minimal tissue reaction.

Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, completed between 60 and 90 days. Tensile strength retention maintains the necessary support during the first weeks of healing, while the tissue recovers its own resistance.

The HRT 26 needle features a ½-circle curvature with a cylindrical body and trocar (tapercut) point: a converging triangular section point that combines firm penetration in moderate tension tissues with contained trauma, reducing tissue tearing when passing the strand. The fluted violet colour ensures optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and non-resterilizable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP112HRT2630

Parameter Specification
Reference (SKU) AMP112HRT2630
Range / Quality Prime
Material 100 % Polyglycolic Acid (PGA) synthetic absorbable
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish
Gauge / size USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia
Approximate diameter 0.20 – 0.249 mm (indicative according to USP/EP)
Thread colour Fluted violet (colourless version available in the range)
Thread length 75 cm
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Tapercut (converging triangular cross-section)
Needle size HRT 26 mm (26 mm), 1 needle per suture
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units; minimum order of 30 boxes

3.2. Tensile strength retention profile after implantation

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 (this product) 2 0.20 – 0.249 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable on the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. After verifying the documentation from the main equivalent manufacturers, no official equivalence table from the manufacturer has been found for a 1:1 cross with the exact configuration of this reference (HRT 26 mm tapercut needle, USP 3/0 gauge, 75 cm thread and violet colour); the references found in equivalent catalogues present differences in needle size or gauge, and therefore do not meet the 1:1 interchangeability tolerance.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. As equivalent families on the market to verify reference by reference in their official data sheet before a substitution, the lines of 100 % braided coated PGA are cited —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Assucryl PGA (Assut), Atramat PGA (Internacional Farmacéutica), Resorba PGA and the historic Dexon (limited availability)— and those of polyglactin 910 —Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 3/0 gauge, 26 mm ½-circle needle size, trocar point, 75 cm thread length and violet colour. The copolymer ranges of polyglactin 910 (PGLA) are chemically different from PGA homopolymer (absorption 56 to 72 days versus 60-90 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department. The brands cited belong to their respective manufacturers and are mentioned solely as a comparative reference.

Within the Cahnos catalogue, the standard quality alternative with the same HRT 26 needle configuration, 3/0 gauge and 75 cm strand is reference AM112HRT2630, and the alternative in polyglactin 910 (PGLA) with the same HRT 26 mm needle and 3/0 gauge is reference P1L18HRT2630 (70 cm thread, absorption 56-72 days).

5. Selection tips and variants of interest

USP 3/0 (metric 2) gauge offers an ideal balance between initial strength and handleability for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures. The HRT ½-circle trocar (tapercut) needle is the appropriate choice for firm or slightly fibrous tissues where clean penetration without tearing is required; if you need a fully atraumatic point for soft tissues, consider the conical point (HR) versions of the same PGA family.

Reference Variant of interest
AMP112HRT2630 PGA Prime, HRT26 trocar point needle, USP 3/0, violet, 75 cm (current product)
AM112HRT2630 PGA standard quality, same HRT26 configuration, USP 3/0, violet, 75 cm (economy range)
AMP112HRT2620 PGA Prime, same HRT26 needle, USP 2/0, violet, 75 cm (higher gauge)
AMP112HR2630 PGA Prime, HR26 conical point needle, USP 3/0, violet, 75 cm (atraumatic point)
AMP112HS2630 PGA Prime, HS26 reverse cutting triangular point needle, USP 3/0, violet, 75 cm (firm tissues)
P1L18HRT2630 Polyglactin 910 (PGLA) Prime, HRT26 needle, USP 3/0, violet, 70 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, and keep the reference together with the batch number for traceability in the operating theatre. For B2B volume conditions or to enquire about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % Polyglycolic Acid (PGA) with polycaprolactone and calcium stearate coating

Structure

Multifilament braided, grooved, coated

Gauge

USP 3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm (indicative according to USP/EP)

Colour

Violet grooved

Needle shape

½ circle (approx. 180°)

Tip type

Trocar / Tapercut (cylindrical body)

Needle size

HRT 26 (26 mm), 1 needle per suture

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Quality

Prime (range PREMISUT)

Manufacturer reference

P112HRT2630

Indications

Tissue approximation, ligatures and general surgery

Regulatory standard

USP / European Pharmacopoeia (EP)

Use

Single-use, not re-sterilisable

Medida de aguja

HRT 26

Usp

3/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture Prime | ½ Circle Cylindrical Body Trocar Point (Tapercut) Needle HRT 26 mm | USP Gauge 3/0 (Metric 2) | Fluted Violet Thread 75 cm | Ref. AMP112HRT2630 | Box of 12 units”

Your email address will not be published. Required fields are marked *