Description
1. Product Presentation
The absorbable multifilament suture of polyglycolic acid (PGA) from the PREMISUT range, factory reference 112HR1360 (SKU AM112HR1360), is the reference synthetic absorbable solution for the professional who demands predictable performance, excellent tensile strength and high knot security. This presentation incorporates a ½ circle needle with cylindrical body and conical Taperpoint point of 13 mm (HR13), USP 6/0 gauge (metric 0.7) and violet non-grooved thread of 75 cm.
It is the ideal choice for tissue approximation, ligatures and general surgery, in a professional box format of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure coated with polycaprolactone and calcium stearate. This reference incorporates a non-grooved finish, which provides a regular surface that favours the sliding of the thread through the tissue, smooth handling, low memory and firm and secure knot tying, even in gauges as fine as USP 6/0.
Its absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. During the first weeks of healing it maintains the necessary tensile strength (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks), the precise time for the tissue to recover its own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) combines an atraumatic point, which separates the fibres without cutting effect, with a smooth passage through the tissue: it is the usual configuration in delicate tissues, deep planes and reduced-radius accesses. The violet colour of the thread guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM112HR1360
| Parameter | Specification |
| Reference (SKU) | AM112HR1360 |
| Factory reference | 112HR1360 |
| Brand / Range | PREMISUT – Standard quality |
| Material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Coating | Polycaprolactone and calcium stearate |
| Suture type | Synthetic absorbable braided multifilament (non-ribbed) |
| USP / metric gauge | 6/0 (metric 0.7) |
| Approximate diameter | 0.070 – 0.099 mm (USP/EP standard) |
| Thread colour | Violet |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 13 mm (HR13) |
| Absorption mechanism | Hydrolysis (60–90 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Approximate diameter | Metric size |
| 6/0 | 0.070 – 0.099 mm (USP/EP standard) | 0.7 |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Single-use, not re-sterilisable. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most proven raw materials for synthetic absorbable multifilament suture on the market. At category level, this reference is comparable by category (not interchangeable 1:1) with the main international lines of braided absorbable multifilament suture, such as Ethicon Vicryl (polyglactin 910, violet colour), B. Braun Safil / Novosyn, Medtronic (Covidien) Polysorb, SMI Surgicryl, Assut Assucryl 910, DemeTECH Vitacryl and Atramat.
The main differences compared with these lines are the exact chemical composition (PGA versus polyglactin 910), the absorption profile (60–90 days) and the surface finish of this reference (non-grooved), so any substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size) and presentation in the technical data sheet or IFU of each manufacturer.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
The USP 6/0 gauge (metric 0.7) is indicated for very fine and low-tension tissues: mucosa, subcutaneous tissue, delicate planes and precision approximations. The ½ circle needle with conical point of 13 mm (HR13) is the most atraumatic option for these tissues and smaller-radius accesses.
Within the Cahnos catalogue, the following variants of interest are available:
- AMP112HR1360: same HR 13 mm configuration, USP 6/0, violet 75 cm in Prime quality, for high-demand protocols.
- AM112HR1350: same HR 13 mm needle, USP 5/0 gauge, violet 75 cm (slightly larger diameter for moderate tension).
- AM118HR1340 / AM118HR1330 / AM118HR1320: HR 13 mm needle in USP 4/0, 3/0 and 2/0 gauges, violet thread of 70 cm (larger diameter for increasing tension).
- 1L12HR1360: polyglactin 910 (PGLA) family with the same HR 13 mm needle and USP 6/0 gauge, absorption of 56–72 days, to compare suppliers and unify stocks.
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other manufacturers, contact our technical-commercial team.