Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament suture made of polyglycolic acid (PGA), factory reference 128HR3630 (SKU AM128HR3630) from the Premisut range: the professional choice for general surgery services and procedures requiring a secure, manageable closure with controlled absorption. It combines a ½ circle needle with a cylindrical body and conical point (taperpoint) of 36 mm (HR 36), an undyed grooved thread of 70 cm in USP 3/0 gauge, and an economical presentation in a box of 12 units, designed for the supply of operating theatres, purchasing centres, distributors and surgical material tenders, with a minimum order of 30 boxes. A synthetic, sterile, single-use medical device, with an excellent value for money for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the thread, reduces friction when passing through tissues, improves sliding and guarantees a firm and secure knot tying even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis —a predictable mechanism independent of the patient’s enzymatic activity— over a period of 60 to 90 days, maintaining tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore particularly indicated for approximation of soft tissues, ligatures and general surgery. The undyed colour of the thread offers maximum aesthetic discretion in the surgical field. Sterile product by ethylene oxide (EtO), single-use and not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 128HR3630
| Characteristic | Specification |
| Reference (SKU Cahnos) | AM128HR3630 |
| Factory reference | 128HR3630 (Premisut nomenclature) |
| Thread material | 100% polyglycolic acid (PGA), synthetic absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread colour | Colourless (grooved) |
| Thread length | 70 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | HR 36 (36 mm), 1 needle per thread |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official ranges of the USP/EP Pharmacopoeia for synthetic absorbable sutures, without exceeding its limits.
3.4. Decoding of the official reference
The official reference 128HR3630 is decoded: 128 (undyed thread series of 70 cm) + HR36 (½ circle needle with cylindrical body and conical taperpoint point of 36 mm) + 30 (USP 3/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most well-established medium-duration braided absorbable multifilament on the market and shares an absorption profile (60-90 days), coated braided structure and clinical behaviour with homologous families in the sector. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following match is a functional category comparison verified against the official catalogue and authorised distribution, and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet | J344H – USP 3/0, CT-1 needle of 36 mm, ½ circle, conical tip, 90 cm | Comparable by category (not interchangeable 1:1) | Code verified in Ethicon catalogue and authorised distribution: they match in USP 3/0 gauge, ½ circle curvature, 36 mm conical needle and point family. They differ in: polymer (polyglactin 910 vs. PGA 100%), absorption profile (56-72 days vs. 60-90 days), thread length (90 cm vs. 70 cm), colour (violet vs. undyed) and presentation (box of 36 units vs. 12 units). |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. Homologous ranges in the medium-absorption braided PGA segment include Surgicryl PGA (SMI, series SM1120 with HR needles of round body and conical point in ½ circle, whose codes for HR36 size in 3/0 gauge must be confirmed in the catalogue), Dexon II (Medtronic/Covidien), DemeSORB PGA (DemeTECH) and Atramat (Resorba), as well as the polyglactin 910 lines Coated VICRYL® / VICRYL® Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Assucryl 910 (Assut Sutures), comparable by category, material and absorption profile. For the exact combination USP 3/0 / HR 36 mm conical point needle / 70 cm / undyed, the specific codes of those manufacturers must be confirmed with the manufacturer before any substitution, verifying material, gauge, curvature, needle type and size, thread length, colour and configuration. This geometry (HR36, USP 3/0, 70 cm) is interchangeable with full safety only within Cahnos’s own reference system.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of fine or medium-calibre vessels. The HR36 ½ circle needle with conical point (taperpoint) is atraumatic and ideal for soft and delicate tissues; if you need to pass through firmer and denser tissues (skin, sclera, aponeurosis), consider the reverse cutting (HS) or trocar (HRT) points available in the same range. The undyed colour offers maximum discretion in the surgical field; if you prefer greater thread visibility, request the violet version.
| Variant / Reference | Description |
| AM128HR3630 (128HR3630) | PGA – HR36 conical point – USP 3/0 undyed – 70 cm (this product) |
| AMP128HR3630 | PGA Prime – HR36 conical point – USP 3/0 undyed – 70 cm (superior quality, same geometry) |
| AM128HR2630 (128HR2630) | PGA – HR26 conical point – USP 3/0 undyed – 70 cm (shorter needle, superficial planes) |
| AM113HR3630 (113HR3630) | PGA – HR36 conical point – USP 3/0 violet – 90 cm (greater visibility and length) |
| AM128HR3620 (128HR3620) | PGA – HR36 taper point – USP 2/0 undyed – 70 cm (larger gauge, higher strength) |
| 1L28HR3630 | PGLA polyglactin 910 – HR36 taper point – USP 3/0 undyed – 70 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes, ensuring continuous supply for your healthcare facility. If you require longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep reference 128HR3630 together with the batch number for traceability in the operating theatre, and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact our technical-commercial team.





Reviews