Description
1. Commercial Introduction
The absorbable multifilament suture made of polyglycolic acid (PGA) from the PREMISUT range, factory reference 112HR1740 (SKU AM112HR1740), is the most established medium-duration synthetic reabsorbable solution on the market, designed for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates an atraumatic ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 4/0 gauge (metric 1.5) and a 75 cm violet grooved braided thread.
It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional box format of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers. Price per box.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure and coated with polycaprolactone and calcium stearate. This configuration gives the thread a regular (grooved) surface that favours sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine working gauges such as USP 4/0.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread retains the necessary tensile strength (75 % at 2 weeks, 50 % at 3 and 40 % at 4), just enough time for the tissue to recover its own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The violet grooved colour guarantees optimal visibility of the strand on the surgical field, highly valued in deep planes. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM112HR1740
| Parameter | Specification |
| Reference (SKU) | AM112HR1740 |
| Factory reference | 112HR1740 |
| Brand / Range | PREMISUT – Standard quality |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 4/0 (metric 1.5) |
| Thread diameter | 0.15 – 0.199 mm (USP/EP standard) |
| Thread colour | Braided violet (also available undyed) |
| Thread length | 75 cm |
| Swaged | Single needle (1xHR17) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 17 mm (HR17) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 5/0 | 1 | 0.10 – 0.149 mm |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Single-use, not re-sterilisable. Price per box of 12 units.
4. Equivalences and Cross-References
Coated braided polyglycolic acid is the most established medium-absorption absorbable multifilament raw material in surgical practice (classic family type «Dexon»). For the exact configuration of this reference (single HR17 ½ circle needle with conical point, USP 4/0 gauge, 75 cm violet thread), no code from another commercial house has been found in public sources that reproduces all the characteristics point by point, so no exact 1:1 equivalence with third-party brands is declared.
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. At category level (not interchangeable 1:1) they are homologous lines of coated braided PGA: B. Braun Safil® (PGA range, violet), SMI Surgicryl® PGA, DemeTECH DemeSORB® PGA, Assut Sutures AssuCryl® PGA and the historical Medtronic Dexon® / Dexon II® range. The polyglactin 910 lines (Ethicon Vicryl®, Medtronic Polysorb®, SMI Surgicryl® 910, Assut AssuCryl® 910) share the needle geometry and multifilament behaviour, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not interchangeable 1:1 material to material. Any substitution must be validated code by code verifying material, gauge, needle geometry (shape, body, point and size), attachment, strand length and presentation in the technical data sheet or IFU of each manufacturer.
5. Selection tips and variants of interest
The USP 4/0 gauge (metric 1.5) combines excellent initial tensile strength with a fine diameter, indicated for soft tissues of low-medium tension: subcutaneous tissue, mucosa, delicate planes and precision approximations. The ½ circle conical point needle of 17 mm (HR17) is the most atraumatic option for these tissues and medium-radius accesses, with good control in deep planes; the violet colour offers excellent visibility on the surgical field.
Variants from the same Cahnos catalogue:
- AMP112HR1740: same HR17 configuration, USP 4/0, violet, 75 cm in Prime quality, for high-demand protocols (direct equivalent of the same family).
- AM112HR1730 / AM112HR1750: same HR17 needle in USP 3/0 and 5/0 gauges, for increasing tension or finer tissues.
- AM112HR1720: same HR17 needle in USP 2/0 gauge, for larger thread diameter and increasing tension.
- AM118HR1760: HR17 needle in USP 6/0 gauge, for very fine planes.
- AM112HR1350: same range with HR13 needle (13 mm), for smaller radius accesses.
- 1L12HR1740: polyglactin 910 (PGLA) family with the same HR17 needle and USP 4/0 gauge, absorption of 56–72 days, to compare materials and unify stocks.
- AM412HR1740: polydioxanone (PDO) monofilament with prolonged absorption of 180–210 days, if longer-lasting tissue support is required.
All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, institutional rates or equivalences from other commercial houses, contact our technical-commercial team.