We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Cylindrical Body Taperpoint Conical Point Needle HR17 (17 mm) | USP 3/0 Gauge (Metric 2) | Colourless Thread 70 cm | Box of 12 units | Ref. 128HR1730 (SKU AM128HR1730)

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament polyglycolic acid (PGA) suture from the PREMISUT range, factory reference 128HR1730 (SKU AM128HR1730). Presentation with atraumatic ½ circle needle, cylindrical body and 17 mm Taperpoint conical point (HR17), USP 3/0 gauge (metric 2) and braided thread colourless, 70 cm. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use, minimal tissue reaction and excellent knot security; indicated for soft tissue approximation, ligatures and general surgery. Box of 12 units with a minimum order of 30 boxes and B2B conditions for hospitals and purchasing centres. Price per box.

Se fabrica bajo pedido: el fabricante exige un mínimo de 29 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM128HR1730

Description

1. Product Presentation

The absorbable multifilament polyglycolic acid (PGA) suture from the PREMISUT range, reference 128HR1730 (SKU AM128HR1730), is the reference synthetic absorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 3/0 gauge (metric 2) and colourless braided thread of 70 cm.

It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional format of a box of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.

2. Technical explanation of the material and procedure

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and grooved multifilament structure, coated with polycaprolactone and calcium stearate. This configuration gives the thread a regular surface that favours sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine-to-medium gauges such as USP 3/0.

Its absorption occurs by hydrolysis, a uniform, predictable process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days. During the first weeks of healing, the thread retains the necessary tensile strength (75 % at 2 weeks, 50 % at 3 and 40 % at 4), just enough time for the tissue to recover its own resistance.

The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with controlled passage and minimal injury along the penetration path. The colourless colour of the thread offers maximum discretion on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference AM128HR1730

Parameter Specification
Reference (SKU) AM128HR1730
Factory reference 128HR1730
Brand / Range PREMISUT – Standard quality
Suture type Synthetic absorbable braided multifilament
Material 100 % absorbable polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament, grooved surface
USP / metric gauge 3/0 (metric 2)
Thread diameter 0.20 – 0.249 mm (USP/EP standard)
Thread colour Colourless
Thread length 70 cm
Swaged Single needle (1xHR17)
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (Taperpoint), atraumatic
Needle size 17 mm (HR17)
Absorption mechanism Hydrolysis
Total absorption 60 – 90 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes
Regulatory standard USP/EP

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Coated braided polyglycolic acid is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic family type ‘Dexon’). This PREMISUT reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40 % at 2/3/4 weeks and a single cylindrical Taperpoint needle of 17 mm, has been cross-referenced against official regulatory source (GUDID/FDA) and manufacturer catalogues with the following result:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun Safil® Violet (coated braided polyglycolic acid) SAFIL VIOLET 3/0 (2) 70CM HR17 (M) – catalogue C1048014 / G1048014 / X1048014; DI GUDID 04038653925667 Comparable by category (not interchangeable 1:1) Same 100 % PGA, same USP 3/0 gauge (metric 2), same thread length (70 cm) and same HR17 needle geometry (½ circle, cylindrical body, conical point), confirmed on GUDID/FDA basis; they differ in thread colour (violet versus colourless) and the coating system specific to each house. GUDID record with status ‘not in commercial distribution’: verify IFU and commercial availability in the region before substituting.
SMI (Belgium) Surgicryl® PGA (coated braided polyglycolic acid) 11200117 – USP 3/0 (metric 2), 1/2 circle needle, round body, conical point HR 17 mm, 75 cm, violet (official SMI catalogue, Rev. 10) Comparable by category (not interchangeable 1:1) Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1 %), same absorption 60–90 days and same HR 17 mm needle geometry; they differ in thread length (75 cm versus 70 cm) and colour (violet versus colourless).

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using it in tenders. At category level, they are also homologous coated braided PGA lines: DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historic Medtronic Dexon® / Dexon II® range. The polyglactin 910 lines (Ethicon Vicryl®, Medtronic Polysorb®, B. Braun Safil® Quick, SMI Surgicryl® 910, Assut AssuCryl® 910) share the needle geometry and multifilament behaviour, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not interchangeable 1:1 material for material. Any substitution must be validated code by code, checking material, gauge, needle geometry (shape, body, point and size), attachment, strand length and presentation in each manufacturer’s technical data sheet or IFU. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 3/0 gauge (metric 2) combines excellent initial tensile strength with a fine-to-medium diameter, indicated for the approximation of tissues under moderate tension: subcutaneous tissue, skin, mucosa, fascia and soft tissue in general. The 17 mm (HR17) ½ circle taper-point needle is the most atraumatic option for these tissues, with good control in medium-radius access. The colourless thread is recommended when minimal visibility of the strand over the surgical field is desired.

Variants from the same Cahnos catalogue:

  • AM128HR1740: same HR17 needle, USP 4/0, colourless, 70 cm, for lower-tension tissues.
  • AM118HR1760: HR17 needle in USP 6/0 gauge, violet, for finer planes.
  • 1L18HR1730: polyglactin 910 (PGLA) with the same HR17 needle and USP 3/0 gauge, violet, absorption of 56–72 days, for material comparison.
  • AMP118HR1730-2: double needle 2xHR17 in USP 3/0 gauge, for continuous sutures with anchorage at both ends (Prime quality).
  • AM112HR1750: HR17 needle, USP 5/0 gauge, violet, 75 cm thread, for low-tension tissues.

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, institutional rates or validation of equivalences with other manufacturers, contact our technical-commercial team.

Additional information

Manufacturer reference

128HR1730

Brand / Range

PREMISUT

Suture type

Synthetic absorbable braided multifilament

Material

100 % polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Thread structure

Braided multifilament, grooved

Metric gauge (EP)

2

Thread diameter

0.20 – 0.249 mm (USP/EP standard)

Swaged

Single needle (1xHR17)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint), atraumatic

Needle size

17 mm (HR17)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use

Indications

Approximation of soft tissues, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

USP/EP

Medida de aguja

HR 17

Usp

3/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Cylindrical Body Taperpoint Conical Point Needle HR17 (17 mm) | USP 3/0 Gauge (Metric 2) | Colourless Thread 70 cm | Box of 12 units | Ref. 128HR1730 (SKU AM128HR1730)”

Your email address will not be published. Required fields are marked *