Description
1. Commercial Introduction
The multifilament absorbable polyglycolic acid (PGA) suture, reference 112HR2601 (SKU AM112HR2601) from the Premisut range in normal quality, is the absorbable closure solution your centre needs for general, digestive and gynaecological surgery procedures that require controlled absorption, excellent handling and impeccable knot security. It combines a ½ circle needle with cylindrical body and taperpoint conical point of 26 mm (HR 26) with a 75 cm fluted violet braided thread in USP 1 gauge: a robust and highly versatile configuration for tissue approximation with moderate-high tension, ligatures and general surgery.
It is a synthetic, absorbable, sterile and single-use medical device, with an excellent quality-performance ratio for B2B supply to operating theatres, clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes and special conditions for professional buyers.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100 % absorbable synthetic homopolymer presented in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding, regularises the surface of the strand and facilitates firm, secure knotting, with minimal tissue reaction.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, which is completed between 60 and 90 days. Tensile strength retention maintains the necessary support during the first weeks of healing —75 % at 2 weeks, 50 % at 3 and 40 % at 4—, while the tissue recovers its own resistance.
The HR 26 needle features a ½ circle curvature with a cylindrical body and conical point (taperpoint geometry): an atraumatic point that separates fibres without cutting effect, ideal for hollow organs, subcutaneous tissue, fascia and soft tissue in general. The fluted violet colour ensures optimal visibility on the surgical field throughout the procedure. Product sterilised by ethylene oxide (EtO), single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 112HR2601
| Parameter | Specification |
| Reference (SKU) | AM112HR2601 · factory reference 112HR2601 |
| Range / Quality | Premisut · normal quality |
| Material | 100 % polyglycolic acid (PGA), synthetic absorbable homopolymer |
| Suture type | Synthetic absorbable multifilament |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 1 (metric 4), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.40 – 0.449 mm (indicative according to Pharmacopoeia) |
| Thread colour | Fluted violet (colourless version available in the range) |
| Thread length | 75 cm · 1 needle per suture |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | HR 26 (26 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets); minimum order of 30 boxes |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis (predictable rate) |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 1 (this product) | 4 | 0.40 – 0.449 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The strand diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits. Decoding of the factory reference 112HR2601: 112 (violet thread of 75 cm) + HR26 (½ circle needle, cylindrical body, taperpoint conical point of 26 mm) + 01 (USP 1 gauge). The reference is marketed without altering characters: no digit may be added, removed or reordered when ordering or bidding.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most well-established medium-duration braided multifilament absorbable on the market and shares an absorption profile (60-90 days), coated braided structure (polycaprolactone and calcium stearate) and clinical behaviour with homologous families in the sector.
There is no manufacturer-validated equivalence table that cross-references this reference with other brands for the exact combination USP 1 / HR 26 mm taper-point needle / 75 cm in violet; consult the technical department before use in tenders. Comparable ranges in the medium-absorption braided PGA segment include Dexon / Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Assucryl PGA (Assut Sutures) and Atramat (Resorba); the polyglactin 910 lines —Coated Vicryl / Vicryl Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Novosyn (B. Braun)— are comparable by category for braided structure and clinical use, but have different degradation chemistry and absorption profile (56-72 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (26 mm), ½ circle curvature, point family (taper), suture length (75 cm) and colour.
This geometry (HR26, USP 1, 75 cm, violet) can be interchanged with complete safety only within the Cahnos reference system itself: the same configuration is available in Prime quality under reference AMP112HR2601, and in polyglactin 910 (PGLA) with 56-72 day absorption under references 1L12HR2601 and P1L12HR2601.
5. Selection tips and variants of interest
USP gauge 1 (metric 4) offers an excellent balance between initial strength and handling, indicated for tissues under moderate-to-high tension: fascia, aponeurosis, abdominal wall, deep subcutaneous tissue and ligation of medium-calibre vessels. The ½ circle taper-point HR 26 needle is the atraumatic choice for soft and friable tissues; if firm penetration in fibrous tissue is required, consider the reverse cutting (HS) or trocar (HRT) point versions of the same PGA family.
| Reference | Variant of interest |
| AM112HR2601 (112HR2601) | PGA standard quality, HR26 taper-point needle, USP 1, violet, 75 cm (current product) |
| AMP112HR2601 | PGA Prime, same HR26 geometry, USP 1, violet, 75 cm (premium range) |
| AM112HR2610 (112HR2610) | PGA, same HR26 needle, USP 0, violet, 75 cm (next gauge down) |
| AM112HR2602 (112HR2602) | PGA, same HR26 needle, USP 2, violet, 75 cm (higher strength) |
| 1L12HR2601 | Polyglactin 910 (PGLA), HR26, USP 1, violet, 75 cm (56-72 day absorption) |
| P1L12HR2601 | Polyglactin 910 (PGLA) Prime, HR26, USP 1, violet, 75 cm |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place protected from sunlight. For B2B volume conditions or to enquire about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.