We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture 1/2 Cylindrical Taperpoint Conical Point HR20 (20 mm) | USP 2/0 Gauge (Metric 3) | Violet Fluted Thread 75 cm | Ref. 112HR2020 · Box of 12 units (SKU AM112HR2020)

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture, 100 % polyglycolic acid (PGA) from the Premisut range, factory reference 112HR2020 (SKU AM112HR2020). It features an atraumatic ½ circle needle, cylindrical body and Taperpoint conical point of 20 mm (HR 20), USP 2/0 (metric 3) gauge and 75 cm violet fluted thread coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60–90 days (75 % tensile strength at 2 weeks), sterile by ethylene oxide and single-use. Indicated for approximation of soft tissues, ligatures and general surgery. B2B presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112HR2020

Description

1. Commercial Introduction

At Cahnos we offer you the absorbable multifilament polyglycolic acid (PGA) suture, factory reference 112HR2020 (SKU AM112HR2020) from the Premisut range in standard quality. It is the professional choice for general surgery departments, clinics, purchasing centres and tenders that need a resorbable thread with predictable behaviour, excellent handling and maximum knot security. It combines a 1/2 circle cylindrical body needle with a 20 mm Taperpoint conical point (HR 20), a 75 cm violet fluted thread in USP 2/0 gauge and an economical presentation in a box of 12 units, designed for hospital supply and continuous provision of your centre.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the strand: it reduces friction when passing through tissues (less sawing effect), improves gliding, minimises tissue reactivity and guarantees a firm and secure knot tying even in medium working gauges such as USP 2/0.

The absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed between 60 and 90 days: the thread maintains tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own strength. The HR 20 needle of 1/2 circle with cylindrical body and Taperpoint conical point penetrates by separating the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues. The violet fluted colour ensures optimal visibility on the surgical field. Product sterile by ethylene oxide (EtO), single-use and not resterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference 112HR2020

Parameter Specification
Factory reference 112HR2020 (official nomenclature standard PGA range)
Reference Cahnos (SKU) AM112HR2020
Thread material 100 % polyglycolic acid (PGA), synthetic absorbable homopolymer
Thread structure Braided coated multifilament, fluted finish
Coating Polycaprolactone and calcium stearate
Gauge / size USP 2/0 (metric 3), in accordance with USP/EP Pharmacopoeia
Approximate thread diameter 0.30 – 0.349 mm (indicative according to Pharmacopoeia)
Thread colour Fluted violet (colourless version available in the range)
Thread length 75 cm (1 needle per suture)
Needle shape ½ circle (1/2 circular, 160°), cylindrical body
Needle tip Conical Taperpoint, atraumatic
Needle size HR 20 (20 mm), 1 needle per thread
Swaged 1 needle / 1 suture per unit
Absorption mechanism Hydrolysis; complete between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal; excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and general surgery
Commercial presentation Box of 12 units (individual sterile sachets, batch traceability)

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60–90 days, by hydrolysis (predictable rate)

Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot security. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 (this product) 3 0.30 – 0.349 mm
3/0 2 0.20 – 0.249 mm
4/0 1.5 0.15 – 0.199 mm
0 3.5 0.35 – 0.399 mm

The strand diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits. Decoding of the official reference 112HR2020: 112 (violet thread of 75 cm) + HR20 (1/2 circle cylindrical body needle with 20 mm Taperpoint conical point) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) is the most established medium-duration braided multifilament absorbable on the market and shares an absorption profile (60–90 days), braided structure coated with polycaprolactone and calcium stearate and clinical behaviour with the homologous families in the sector. There is no equivalence table validated by the manufacturer that cross-references this specific reference (100% PGA, HR 20 needle with conical point, USP 2/0, violet, 75 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SMI (Surgical Materials Industries) Surgicryl® PGA – coated braided multifilament, violet, HR needle 1/2 circle conical point SM1130 0126 (HR 26 mm, USP 2/0, 75 cm) Comparable by category (not interchangeable 1:1) Code verified in authorised distribution sources: same PGA polymer, same coating (polycaprolactone and calcium stearate), USP 2/0 gauge and 75 cm length. The needle size differs (26 mm compared to HR 20 of 20 mm); confirm geometry and packaging before substituting.
B. Braun Safil® Violet – coated PGA multifilament, violet G1038406 (SAFIL VIOLET 2/0 (3) 2X70CM) Comparable by category (not interchangeable 1:1) Reference verified in the AccessGUDID regulatory database: same PGA material and USP 2/0 gauge (metric 3), violet colour. The length (70 cm compared to 75 cm), the coating type (polyglyconate compared to polycaprolactone and calcium stearate) differ and no needle is specified in the registration; consult IFU before substituting.

As homologous ranges in the segment of 100% PGA coated braided medium absorption, to be verified reference by reference in its official data sheet before substitution, the following lines are cited: Dexon® / Dexon II® (Medtronic/Covidien), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), Assucryl® PGA (Assut Sutures) and Atramat® (Resorba), as well as the polyglactin 910 lines —Coated VICRYL® (Ethicon), Safil® (B. Braun), Polysorb® (Medtronic)— which, being chemically different from PGA homopolymer (PGLA 90/10 copolymer, absorption 56–72 days), should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.

There is no equivalence table validated by the manufacturer; consult with the technical department before using in tenders. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference. This geometry (HR 20, USP 2/0, 75 cm, violet) is fully interchangeable only within the Cahnos reference system itself.

5. Selection tips and variants of interest

USP 2/0 (metric 3) gauge offers an optimal balance between strength and fineness, indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligation of medium-calibre vessels. The HR 20 needle, ½ circle with Taperpoint conical point, is atraumatic and suitable for delicate tissues and superficial planes; if deeper planes or firmer tissues need to be reached, consider needles with a larger radius (HR 22, HR 26, HR 30) or trocar points (HRT) and reverse cutting points (HS) available in the same range.

Reference / Variant Description
AM112HR2020 (112HR2020) Standard PGA – HR20 conical point – USP 2/0 violet – 75 cm (this product)
AMP112HR2020 (P112HR2020) PGA Prime – HR20 conical point – USP 2/0 violet – 75 cm (same geometry, superior quality)
AM112HR2030 PGA – HR20 – USP 3/0 violet – 75 cm (fine gauge, delicate tissues)
AM112HR2040 PGA – HR20 – USP 4/0 violet – 75 cm (very fine gauge)
AM112HR2220 PGA – HR22 – USP 2/0 violet – 75 cm (slightly larger needle)
AM112HR2620 PGA – HR26 – USP 2/0 violet – 75 cm (medium-depth planes)
1L12HR2020 PGLA polyglactin 910 – HR20 – USP 2/0 violet – 75 cm (absorption 56–72 days)

The violet colour offers maximum visibility in the surgical field; if aesthetic discretion is required in superficial areas, request the same configuration in undyed thread on demand. As this is a sterile single-use product, always check the integrity of the pouch and the expiry date before each procedure, keep the reference 112HR2020 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight and below 30 °C. For special B2B conditions by volume, hospital supply contracts or validation of equivalence with other commercial brands, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

112HR2020

Product line

Premisut – Standard quality (standard PGA)

Thread material

100% polyglycolic acid (PGA) absorbable homopolymer

Thread structure

Braided coated multifilament, fluted finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2/0 (metric 3)

Thread diameter

0.30-0.349 mm (according to USP/EP Pharmacopoeia)

Thread colour

Violet grooved

Needle shape

1/2 circle (160°)

Needle body

Cylindrical

Needle tip

Atraumatic conical Taperpoint

Needle size

HR 20 (20 mm)

Swaged

1 needle / 1 suture

Sterilisation

Ethylene oxide (EtO), single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft tissues, ligatures and general surgery

Medida de aguja

HR 20

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture 1/2 Cylindrical Taperpoint Conical Point HR20 (20 mm) | USP 2/0 Gauge (Metric 3) | Violet Fluted Thread 75 cm | Ref. 112HR2020 · Box of 12 units (SKU AM112HR2020)”