Description
Absorbable Multifilament PGA Suture — ½ Circle Taper Point HR40 Needle
Synthetic absorbable suture of 100% polyglycolic acid (PGA) in a coated braided multifilament construction, designed for surgical applications requiring controlled reabsorption, gentle tissue handling and total knot reliability. Its balance of flexibility, tensile strength and slip makes it a recurring choice in general and specialised operating theatres.
Technical features and clinical performance
The PGA multifilament thread degrades by hydrolysis, with no need for removal, and maintains tensile strength during the critical phases of healing: it retains 75% of its initial strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, with complete absorption between 60 and 90 days. The polycaprolactone and calcium stearate coating improves passage through tissue and facilitates tying and repositioning of the knot, reducing friction and the sawing effect. The ½ circle needle with cylindrical body and 40 mm conical taperpoint tip allows atraumatic penetration, ideal for soft tissues, fascia, peritoneum, gastrointestinal tract and urology.
Technical specifications
| Parameter | Specification |
|---|---|
| Material | Polyglycolic acid (PGA) 100%, braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Structure | Synthetic absorbable multifilament (braided) |
| Gauge | USP 0 (metric 3.5) |
| Needle | ½ circle, cylindrical body, taperpoint conical point, 40 mm (HR40) |
| Thread length | 90 cm |
| Colour | Fluted violet |
| Absorption | Complete hydrolysis in 60-90 days |
| Strength retention | 75% (2 weeks) · 50% (3 weeks) · 40% (4 weeks) |
| Sterilisation | Ethylene oxide (EO) |
| References | SKU AM113HR4010 · Manufacturer ref. 113HR4010 |
| Presentation | Box of 12 units |
Equivalences and cross-references
The technical profile of this product (coated PGA multifilament, USP size 0, 90 cm thread, ½ circle 40 mm needle with conical/taper point) is comparable at category level with the main medium-term braided PGA sutures on the market. The following cross-reference has been verified in the official catalogue and independent sources:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences |
|---|---|---|---|---|
| B. Braun (Aesculap) | Safil® Violet — coated PGA multifilament, USP 0 (3.5), 90 cm, ½ circle 40 mm HR40s needle | C1048556 | Comparable by category (not interchangeable 1:1) | Same material, size and length; the Safil HR40s needle has a reinforced round-body conical point (heavy taper) versus a standard taperpoint conical point; approximate retention profile (60-70% at 14 days) |
There is no manufacturer-validated equivalence table declaring 1:1 interchangeability with other brands; consult the technical department before use in tenders. As homologous reference families for their clinical indication and medium-term absorbable braided construction, the violet PGA multifilament lines from B. Braun (Safil®) and the braided coated polyglactin 910 sutures from J&J MedTech (Vicryl®, code pending confirmation in the official technical data sheet for the USP 0 / 40 mm ½ circle conical point needle combination) are cited. Always verify exact material, size, needle geometry and strength retention in the manufacturer’s technical data sheet before substituting.
Selection tips and variants of interest
For procedures on low-elasticity tissues or with a requirement for prolonged support during healing, prioritise the 75% retention at 2 weeks of this PGA. If you need a greater penetration radius or deeper tissues, consider 36 mm (HR36) or 48 mm (HR48) needles within the same line; if you prefer a smaller size for fine tissue, the USP 2/0 and 3/0 presentations with HR26-HR36 needles offer the same absorption behaviour. In vascular tissue surgery or where less needle-point trauma is required, consult the blunt-point (HRN) variants of the same family. All presentations are supplied in a box of 12 sterile units, ready for use.





Reviews