We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 26 mm | USP 2 Gauge | Violet Fluted Thread 75 cm | Box of 12 units | Ref. AMP112HR2602

Original price was: 43,28 €.Current price is: 32,60 €.

Synthetic absorbable multifilament suture of 100% polyglycolic acid (PGA) from the Prime range, with a ½ circle needle with cylindrical body and conical point (taperpoint) of 26 mm (HR 26), USP 2 gauge and 75 cm violet grooved braided thread. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide and single-use, it offers minimal tissue reaction, excellent handling and great knot security. Indicated for tissue approximation, ligatures and general surgery. Presentation in a box of 12 units with a minimum order of 30 boxes; ideal for B2B supply to operating theatres, clinics and purchasing centres. Ref. AMP112HR2602.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP112HR2602

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference AMP112HR2602, is the trusted choice for B2B supply to operating theatres, general surgery departments, clinics and purchasing centres that need a synthetic reabsorbable thread with predictable behaviour, excellent handling and a highly competitive quality-to-performance ratio. Its ½ circle needle with cylindrical body and conical point (taperpoint) of 26 mm (HR 26) ensures atraumatic passage through tissue, while the 75 cm violet thread in USP 2 gauge offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with standards of excellence in every procedure.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable homopolymer that is reabsorbed by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. The multifilament braided configuration with a polycaprolactone and calcium stearate coating, with a grooved finish, provides a regular surface that facilitates the passage of the thread through tissue, excellent flexibility, firm and secure knot tying and smooth traction, essential qualities in soft and friable tissues. The ½ circular needle with cylindrical body and conical point (taperpoint) HR of 26 mm separates the fibres without a cutting effect, minimising trauma to the tissue bed; the violet colour of the thread guarantees optimal visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

Reference (SKU) AMP112HR2602
Quality / range Prime
Material 100 % absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2 (metric 5)
Thread colour Violet (also available colourless in the family)
Needle shape ½ circle
Tip type Conical point (taperpoint), cylindrical body
Needle size HR 26 mm
Thread length 75 cm
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes

Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %

Complete absorption by hydrolysis between 60 and 90 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. USP 2 gauge (metric 5) provides high tensile support for tissues subjected to moderate-to-high traction: fascia, aponeurosis, deep subcutaneous tissue and medium-to-high calibre vascular ligatures.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) homopolymer is the classic synthetic multifilament absorbable, while polyglactin 910 (PGLA), a copolymer of glycolide and L-lactide, is today the most widely used braided material in surgical practice; both share a clinical family (approximation of soft tissues and ligatures) but have differentiated absorption profiles. At category level, this reference is comparable to the absorbable braided lines of the main international manufacturers, including Vicryl / Vicryl Plus from Ethicon (Johnson & Johnson), Safil from B. Braun, Polysorb from Medtronic/Covidien, Dexon (PGA) from the Medtronic/Covidien family and Surgicryl from SMI. However, as the exact material (PGA vs. PGLA) and the needle codifications of each house differ, a 1:1 equivalence with a closed reference cannot be declared; the official cross-reference tables validated by these manufacturers do not exist for this specific configuration (HR 26 mm needle).

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the Cahnos catalogue, the same configuration (HR 26 mm needle, USP 2 gauge, 75 cm violet thread) is available in normal quality under reference AM112HR2602, and in polyglactin 910 (PGLA) from the Prime range under reference P1L12HR2602 (absorption 56-72 days), recommended when a slightly shorter reabsorption profile is preferred.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 2 gauge is indicated for tissues subjected to high traction: fascia, aponeurosis, deep subcutaneous tissue and medium-to-high calibre vascular ligatures. The 26 mm HR conical point needle is the recommended atraumatic option for soft and friable tissues. Variants of the same PGA Prime family from Cahnos: AMP112HR2601 (USP 1), AMP112HR2620 (USP 2/0) and AMP112HR2020 (HR 20 mm needle, USP 2/0). If you need longer force retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Reference

AMP112HR2602

Material

100 % absorbable polyglycolic acid (PGA)

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5)

Needle type

Cylindrical / conical point (taperpoint)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 26

Usp

2

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture | Needle ½ Circle Cylindrical Conical Point Taperpoint HR 26 mm | USP 2 Gauge | Violet Fluted Thread 75 cm | Box of 12 units | Ref. AMP112HR2602”

Your email address will not be published. Required fields are marked *