Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference AMP112HR2602, is the trusted choice for B2B supply to operating theatres, general surgery departments, clinics and purchasing centres that need a synthetic reabsorbable thread with predictable behaviour, excellent handling and a highly competitive quality-to-performance ratio. Its ½ circle needle with cylindrical body and conical point (taperpoint) of 26 mm (HR 26) ensures atraumatic passage through tissue, while the 75 cm violet thread in USP 2 gauge offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with standards of excellence in every procedure.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable homopolymer that is reabsorbed by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. The multifilament braided configuration with a polycaprolactone and calcium stearate coating, with a grooved finish, provides a regular surface that facilitates the passage of the thread through tissue, excellent flexibility, firm and secure knot tying and smooth traction, essential qualities in soft and friable tissues. The ½ circular needle with cylindrical body and conical point (taperpoint) HR of 26 mm separates the fibres without a cutting effect, minimising trauma to the tissue bed; the violet colour of the thread guarantees optimal visibility throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Reference (SKU) | AMP112HR2602 |
| Quality / range | Prime |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2 (metric 5) |
| Thread colour | Violet (also available colourless in the family) |
| Needle shape | ½ circle |
| Tip type | Conical point (taperpoint), cylindrical body |
| Needle size | HR 26 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (60-90 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
Complete absorption by hydrolysis between 60 and 90 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. USP 2 gauge (metric 5) provides high tensile support for tissues subjected to moderate-to-high traction: fascia, aponeurosis, deep subcutaneous tissue and medium-to-high calibre vascular ligatures.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) homopolymer is the classic synthetic multifilament absorbable, while polyglactin 910 (PGLA), a copolymer of glycolide and L-lactide, is today the most widely used braided material in surgical practice; both share a clinical family (approximation of soft tissues and ligatures) but have differentiated absorption profiles. At category level, this reference is comparable to the absorbable braided lines of the main international manufacturers, including Vicryl / Vicryl Plus from Ethicon (Johnson & Johnson), Safil from B. Braun, Polysorb from Medtronic/Covidien, Dexon (PGA) from the Medtronic/Covidien family and Surgicryl from SMI. However, as the exact material (PGA vs. PGLA) and the needle codifications of each house differ, a 1:1 equivalence with a closed reference cannot be declared; the official cross-reference tables validated by these manufacturers do not exist for this specific configuration (HR 26 mm needle).
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the Cahnos catalogue, the same configuration (HR 26 mm needle, USP 2 gauge, 75 cm violet thread) is available in normal quality under reference AM112HR2602, and in polyglactin 910 (PGLA) from the Prime range under reference P1L12HR2602 (absorption 56-72 days), recommended when a slightly shorter reabsorption profile is preferred.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 2 gauge is indicated for tissues subjected to high traction: fascia, aponeurosis, deep subcutaneous tissue and medium-to-high calibre vascular ligatures. The 26 mm HR conical point needle is the recommended atraumatic option for soft and friable tissues. Variants of the same PGA Prime family from Cahnos: AMP112HR2601 (USP 1), AMP112HR2620 (USP 2/0) and AMP112HR2020 (HR 20 mm needle, USP 2/0). If you need longer force retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact the technical-commercial team at Cahnos.