Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, factory reference P112HR2030 (SKU AMP112HR2030). It is the professional choice for general surgery departments and procedures requiring secure closure, excellent thread handling and fully controlled reabsorption. It combines a ½ circle needle with cylindrical body and 20 mm taperpoint conical tip (HR 20), a 75 cm violet grooved thread in USP 3/0 gauge and a B2B presentation in a box of 12 units, designed for hospital supply, clinics, purchasing groups and tenders. A synthetic, sterile, single-use medical device with an excellent quality-price ratio for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the thread surface, reduces friction when passing through tissues (less sawing effect), improves sliding, minimises tissue reactivity and guarantees firm, secure knot tying even in fine-to-medium working gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed within 60 to 90 days: the thread maintains tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own strength. The HR 20 ½ circle needle with cylindrical body and taperpoint conical tip penetrates by separating the fibres without a cutting effect, making it especially atraumatic for soft and friable tissues, ligatures and tissue approximation in general surgery. The violet grooved colour guarantees optimal visibility on the surgical field. Product sterilised by ethylene oxide, single-use and non-reesterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P112HR2030
| Factory reference | P112HR2030 (official PGA Prime nomenclature) |
| Reference Cahnos (SKU) | AMP112HR2030 |
| Range / quality | Prime (premium range of absorbable sutures) |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
| Thread colour | Fluted violet (colourless version available in the range) |
| Thread length | 75 cm (1 needle per suture) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Needle tip | Conical taperpoint (atraumatic) |
| Needle size | HR 20 (20 mm) |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets, batch traceability) |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; medical device with CE marking |
3.2. Absorption profile and tensile strength retention
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Complete absorption | 60–90 days by hydrolysis (predictable and uniform rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying. Absorption range and retention values copied literally from the manufacturer’s documentation, without extending the limits.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
4. Equivalences and Cross-References
Braided and coated multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. There is no manufacturer-validated equivalence table cross-referencing this specific reference (100% PGA, HR 20 taperpoint needle, USP 3/0, violet, 75 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and must not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | Safil® Violet – braided coated multifilament polyglycolic acid, violet colour, USP 3/0 gauge (metric 2), HR20 cylindrical ½ circle needle | C1048766 (SAFIL VIOLET 3/0 (2) 70CM HR20 (M)) | Comparable by category (not interchangeable 1:1) | Code confirmed in official B. Braun catalogue: material (100% PGA), coated braided multifilament structure, USP 3/0 gauge, ½ circle curvature, HR20 cylindrical 20 mm needle and violet colour match. Thread length (70 cm vs 75 cm) and commercial coating type (polyglyconate vs polycaprolactone and calcium stearate) differ. Validate in the technical data sheet/IFU before substituting in a tender. |
As homologous ranges in the 100% PGA braided coated medium-absorption segment, to be verified reference by reference in their official data sheet before substitution, the following lines are cited: Dexon® II (Medtronic), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), Atramat® (Resorba) and Assucryl® PGA (Assut Sutures). The copolymer polyglactin 910 (PGLA) ranges —Coated VICRYL® (Ethicon), Safil® Quick/Novosyn® (B. Braun), Polysorb® (Medtronic)— are chemically different from PGA homopolymer (90/10 copolymer, 56–72 day absorption) and must not be treated as 1:1 interchangeable without validation by the pharmacy service or the technical department. This geometry (HR20, USP 3/0, 75 cm) is fully safely interchangeable only within the Prime family reference system of Cahnos itself. There is no manufacturer-validated equivalence table; consult the technical department before use in a tender. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) is a very versatile fine-to-medium size, indicated for subcutaneous tissue, superficial fascia, soft tissue approximation and ligation of fine-calibre vessels, with reliable healing support during the first 3–4 weeks. The HR 20 ½ circle needle with taperpoint conical tip combines the sharp entry of the tip with the non-traumatic passage of the cylindrical body: it is the recommended option for superficial fields and soft tissues where an atraumatic passage is sought, without a broad cutting effect and with minimal bleeding. The violet colour guarantees high visibility on the surgical field; if maximum discretion is preferred, a colourless version of the same configuration is available.
| Reference / Variant | Description |
| AMP112HR2030 (P112HR2030) | PGA Prime – HR20 taperpoint – USP 3/0 violet – 75 cm (this product) |
| AM112HR2030 | Standard PGA – HR20 taperpoint – USP 3/0 violet – 75 cm (economical alternative, same geometry) |
| AMP112HR2020 | PGA Prime – HR20 – USP 2/0 violet – 75 cm (higher strength) |
| AMP112HR2040 | PGA Prime – HR20 – USP 4/0 violet – 75 cm (finer for delicate tissues) |
| AMP112HR2230 | PGA Prime – HR22 conical point – USP 3/0 violet – 75 cm (slightly larger needle) |
| AMP112HR2630 | PGA Prime – HR26 taperpoint – USP 3/0 violet – 75 cm (medium-depth planes) |
| P1L12HR2030 | PGLA Prime (polyglactin 910) – HR20 – USP 3/0 violet – 75 cm (56–72 day absorption) |
If the procedure requires longer wound support, consider polyglactin 910 PGLA (56–72 days), polyglecaprone PGCL (90–120 days) or polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA RAPID (40–45 days). All references are supplied in boxes of 12 units; the minimum order is 30 boxes. Sterility and storage: sterile product by ethylene oxide and single-use; check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight and below 30 °C. For special B2B conditions by volume, hospital supply contracts or validation of equivalence with other commercial brands, contact the technical-commercial team of Cahnos.