Description
1. Commercial Introduction
The PGA Prime Multifilament Absorbable Suture from Cahnos is the choice of the professional who demands a resorbable suture with predictable handling, secure knotting and consistent performance in the operating theatre. This configuration combines a braided strand of 100% synthetic polyglycolic acid (PGA), colourless, grooved and 70 cm long, with a ½ circle needle with cylindrical body and 22 mm Taperpoint taper point (HR22 profile): the ideal option for soft tissue approximation, ligatures and general surgery, with an excellent quality-to-price ratio for hospital replenishment, purchasing groups and B2B tenders. Presentation in a box of 12 units with a minimum order of 30 boxes.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% synthetic polymer absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating regularises the surface of the strand: it reduces friction when passing through tissues (less saw effect), improves glide, minimises tissue reactivity and facilitates firm, secure knot tying, even in fine gauges such as USP 4/0.
Its degradation profile is designed for short-to-medium duration healing: it retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, completing absorption by hydrolysis between 60 and 90 days, independently of the patient’s enzymatic activity. The HR22 needle features a ½ circle curvature (160°) with cylindrical body and Taperpoint taper point: the round body passes through soft tissues atraumatically and the taper point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. The colourless colour provides maximum discretion in the surgical field. Product sterile by ethylene oxide (EO), single-use and non-resterilisable.
3. Technical Specifications
3.1. Technical data sheet for the reference (Ref. P128HR2240 · SKU AMP128HR2240)
| Parameter | Specification |
| Factory reference | P128HR2240 (official PGA Prime nomenclature) |
| Reference Cahnos (SKU) | AMP128HR2240 |
| Brand / quality | Prime (premium range) |
| Thread material | 100% polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided coated multifilament, fluted finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
| Thread length | 70 cm (free end, without loop) |
| Thread colour | Colourless (violet version available in the family) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Needle tip | Taperpoint conical (atraumatic) |
| Needle size | HR 22 (22 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 60 and 90 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets, batch traceability) |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; medical device with CE marking |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Complete absorption | 60 – 90 days by hydrolysis (predictable and uniform rate) |
The profile cited corresponds to the standard absorption formulation of the PGA line (60–90 days); it must not be confused with rapid-absorption PGA (RAPID line, 40–45 days) or with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate.
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands in the exact configuration (PGA Prime, ½ circle HR 22 mm taper-point needle, USP 4/0 gauge, colourless 70 cm suture); consult the technical department before use in tenders. Homologous families in the 100% braided coated PGA segment include Safil® (B. Braun), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), Dexon II (Medtronic/Covidien), Assucryl (Assut) and Atramat (Resorba); comparable lines by category in polyglactin 910 (PGLA) —chemically different, absorption 56–72 days— include Coated VICRYL® / VICRYL® Plus (Ethicon), Novosyn® (B. Braun) and Polysorb (Medtronic). In all cases, verification must be carried out property by property —exact material, USP 4/0 gauge, multifilament structure, ½ circle curvature, taper-point family, 22 mm needle length, 70 cm strand, colour, 1-needle configuration and CE/MDR regulatory classification— before any substitution; no unverified cross-reference codes are published. Within the system itself, the PGA Prime family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided gauge and needle geometry are respected. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP 4/0 gauge (metric 1.5) is a very fine size, indicated for delicate, low-tension tissues: fine skin, mucosa, subcutaneous tissue, superficial planes and ligation of fine-calibre vessels, where minimal trauma and aesthetic healing are sought. The HR22 ½ circle needle with Taperpoint taper point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option for medium fields and soft tissues where an atraumatic passage is sought, without a broad cutting effect and with minimal bleeding. If you need to pass through firmer, denser tissues (skin, fascia, sclera), consider the reverse cutting (HS) or trocar (HRT) points available in the same range. The colourless colour offers maximum discretion over the surgical field; if you prefer greater visibility of the strand, request the violet version of the same family.
| Variant (SKU) | Description |
| AMP128HR2240 (P128HR2240) | PGA Prime – HR22 taperpoint – USP 4/0 colourless – 70 cm (current product) |
| AM128HR2240 (128HR2240) | Standard PGA – HR22 taperpoint – USP 4/0 colourless – 70 cm (same configuration, standard range; direct equivalent within the same manufacturer) |
| AMP128HR2230 (P128HR2230) | PGA Prime – HR22 taperpoint – USP 3/0 undyed – 70 cm (slightly larger gauge) |
| AMP112HR2230 (P112HR2230) | PGA Prime – HR22 taperpoint – USP 3/0 violet – 75 cm (same geometry, different colour and length) |
| AMP128HR2220 (P128HR2220) | PGA Prime – HR22 taperpoint – USP 2/0 undyed – 70 cm (larger gauge, greater strength) |
| AMP128HR1740 (P128HR1740) | PGA Prime – HR17 taperpoint – USP 4/0 undyed – 70 cm (shorter needle, very superficial planes) |
| 1L28HR2240 | PGLA polyglactin 910 – HR22 taperpoint – USP 4/0 undyed – 70 cm (absorption 56–72 days) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes. If the procedure requires longer wound support, consider the polydioxanone (PDO, 180–210 days) or polyglecaprone PGCL (90–120 days) families; if a shorter absorption profile is required, consider PGAR RAPID (40–45 days). Sterility and storage: product sterile by ethylene oxide and single-use; check the integrity of the pouch and the expiry date before each procedure, keep reference P128HR2240 together with the batch number for traceability in the operating theatre and store below 30 °C, protected from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalences with other manufacturers, contact the technical-commercial team at Cahnos.





Reviews