Description
1. Introduction
The Absorbable Multifilament PGA Prime Suture (ref. P113HR4002 / SKU AMP113HR4002) is a high-performance synthetic absorbable suture, designed for general surgery procedures that require controlled absorption, atraumatic passage through tissue and total knot reliability. Its braided polyglycolic acid construction, coated and dyed in fluted violet, combines smooth passage, high initial strength and a predictable degradation rate during the critical healing period.
2. Technical Explanation
This suture is composed of 100% polyglycolic acid (PGA), a synthetic absorbable polymer that degrades by hydrolysis in the body without the need to remove the thread. The braided multifilament is coated with polycaprolactone and calcium stearate, which reduces friction when passing through tissue, minimises the saw effect and facilitates knot compaction without compromising its security. The ½ circle needle with cylindrical body and tapered conical point (Taperpoint) of 40 mm (designation HR40) separates the fibres of soft tissue without cutting them, offering an atraumatic passage especially indicated for soft tissues, parenchymatous structures and ligatures. The product is sterilised by ethylene oxide and is single-use.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament |
| Coating | Polycaprolactone and calcium stearate (fluted thread) |
| Gauge | USP 2 (metric 5) |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle type | Cylindrical body, taper point (Taperpoint) |
| Needle size | 40 mm (HR40) |
| Colour | Violet grooved |
| Absorption | Completes between 60 and 90 days by hydrolysis |
| Strength retention | 2 weeks: 75 % | 3 weeks: 50 % | 4 weeks: 40 % |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use |
| Presentation | Box of 12 sterile units |
| Manufacturer reference | P113HR4002 (SKU AMP113HR4002) |
| Indications | Approximation of soft tissues, ligatures and general surgery |
4. Equivalences and Cross-References
Due to its characteristics (absorbable braided multifilament PGA, ½ circle needle with conical point of 40 mm, USP 2 gauge, 90 cm thread in violet), this product falls into the category of medium-term absorbable synthetic sutures. Below are listed references verified against public sources:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| B. Braun (Safil®) | Safil Violet, PGA multifilament | GUDID 04038653946402 (SAFIL VIOLET 2 (5) 90CM HR40S) | Comparable by category (not interchangeable 1:1) | Same material, USP 2 gauge, 90 cm length and 40 mm conical needle (HR40S). The coating type differs (polyglyconate in Safil) and the exact needle nomenclature; verify IFU before substituting. |
| Aston Medical / Medical Sutures (LuxCryl) | LuxCryl PGA, braided multifilament | PG02HR40 | Comparable by category (not interchangeable 1:1) | Braided violet PGA USP 2 (EP 5), 90 cm, HR40 needle of 40 mm conical point cylindrical body, box of 12 units. Very similar configuration; confirm needle finish and certifications in official datasheet. |
Homologous families of coated braided PGA are also recognised, such as Dexon® (Medtronic/Covidien) or Surgicryl® (SMI), without a validated cross-reference code in public sources. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders or direct substitution, verifying USP gauge, thread length and exact needle geometry.
5. Selection tips and variants of interest
The USP 2 gauge with HR40 needle of 40 mm and 90 cm thread is designed for high-tension tissues and closures requiring prolonged support. If the procedure requires less thread, consider the Prime USP 2 version of 70 cm (ref. AMP118HR4002); for smaller gauges, the Prime USP 1 (AMP113HR4001) and USP 0 (AMP113HR4010) versions are available in 90 cm, and USP 2/0 (AMP112HR4020) in 70 cm, all with HR40 needle in a box of 12 units. Always verify the USP gauge, needle size and shape, and thread length indicated in the surgical schedule. Before use, check the integrity of the pouch and the expiry date.





Reviews
There are no reviews yet.