Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture in Prime quality from the Premisut range is the reference surgical closure solution for hospitals, general surgery theatres, private clinics and B2B purchasing groups that demand fully predictable performance, excellent tensile strength and great knot security. This presentation mounts a ½ circle needle with cylindrical body and Taperpoint conical point of 45 mm in Heavy version (needle with a larger wire gauge for medium-to-high resistance tissues), USP 1 gauge and 75 cm violet fluted thread.
Each unit is supplied sterile and ready to use, in a box of 12 units with batch traceability, in a format aimed at hospital replenishment, tenders and public procurement. Line reference Premisut 112HR4501H (SKU Cahnos AM112HR4501H).
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a polycaprolactone and calcium stearate coating. This configuration provides great flexibility, low shape memory and a contained friction coefficient, which favours thread sliding through tissue, very smooth handling and a firm, secure knot, even in medium-to-high diameter gauges such as USP 1.
Absorption occurs by hydrolysis, a uniform mechanism independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days and minimal tissue reaction. During the first weeks of healing, the thread maintains the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 45 mm separates the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with controlled passage and minimal injury along the penetration path. The Heavy version reinforces the needle wire for surgeries requiring deep planes and greater resistance during penetration. The fluted violet colour ensures optimal visibility over the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Characteristic | Specification |
|---|---|
| Reference (SKU Cahnos) | AM112HR4501H (line ref. 112HR4501H) |
| Range / Quality | Premisut, Prime quality (Heavy range with reinforced needle) |
| Suture type | Absorbable synthetic multifilament |
| Composition | 100 % polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved finish |
| Gauge | USP 1 (metric 4); approximate diameter 0.40 – 0.499 mm (USP/EP) |
| Thread colour | Violet (also available colourless) |
| Thread length | 75 cm (1 thread, 1 needle) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, tapered and atraumatic |
| Needle size | 45 mm (HR 45 Heavy) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable and consistent absorption rate. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.
4. Equivalences and Cross-References
Braided coated polyglycolic acid (PGA) is the most well-established absorbable multifilament medium-absorption raw material in surgical practice (classic «Dexon» type family). This reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40 % at 2/3/4 weeks, shares polymer, coating (polycaprolactone and calcium stearate) and clinical profile with homologous 100% PGA lines on the market.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet | J331H (close reference, not 1:1) | Comparable by category (not interchangeable 1:1) | They match in USP 1 gauge, ½ curvature, conical point and colour; they differ in polymer (PGLA 90/10 copolymer vs. PGA homopolymer), thread length and absorption window (56–72 days vs. 60–90 days). Do not treat as interchangeable without validation from the pharmacy service. |
| Laboratory Aragó | Atramat® – coated braided multifilament PGA, violet | S-2042 (confirm gauge/needle on official data sheet) | Comparable by category (not interchangeable 1:1) | Same PGA polymer and absorption profile in medium; verify USP 1 gauge, ½ circle conical needle of 45 mm in Heavy version, 75 cm length and colour in the manufacturer’s datasheet before substituting. |
As homologous families of 100% braided coated PGA to verify reference by reference in their official datasheet before substitution, the following lines are cited: Safil® (B. Braun), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), AssuCryl® (Assut) and the historical range Dexon® II (Medtronic/Covidien), always checking polymer, USP 1 gauge, ½ circle curvature, 45 mm conical point, Heavy configuration with a single needle, 75 cm thread length and violet colour. The copolymeric polyglactin 910 ranges (Vicryl®, Polysorb®, Novosyn®) are chemically different from PGA homopolymer and should not be treated as interchangeable 1:1 without validation from the pharmacy service or the technical department.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (PGA multifilament Prime Heavy, ½ circle conical Taperpoint HR45 needle of 45 mm, USP 1 gauge, 75 cm violet thread) with closed codes from other commercial houses; consult the technical department before using in tenders.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring high initial resistance: fascia, aponeurosis, muscle planes, abdominal wall and moderate-to-high tension closures. The ½ circle needle with conical Taperpoint point separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point (HRN), while for fibrous and dense structures the trocar point (Tapercut) is recommended. The Heavy version is preferable when a more robust needle is required for deep planes and tissues of greater consistency.
| Reference | Variant |
|---|---|
| AM112HR4501H | PGA Prime Heavy USP 1, HR 45 mm needle, violet, 75 cm (current product) |
| AMP112HR4501H | PGA Prime Heavy USP 1, HR 45 mm needle, violet, 75 cm (direct equivalent in the Prime Heavy range) |
| AM112HR4510 | PGA Normal quality, USP 0, HR 45 needle, violet, 75 cm (smaller gauge) |
| AM118HR4502 | PGA Normal quality, USP 2, HR 45 needle, violet, 70 cm (larger gauge) |
| AM113HR4502 | PGA Normal quality, USP 2, HR 45 needle, violet, 90 cm (longer thread) |
| AM112HR4001H | PGA Heavy USP 1, HR 40 mm needle, violet, 75 cm (smaller radius needle) |
| P1L12HR4501H | PGLA Prime Heavy USP 1, HR 45 mm needle, violet (alternative in polyglactin 910, absorption 56–72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 units. If you require longer force retention (180–210 days), consider the polydioxanone (PDO) family. As this is sterile single-use material, check the integrity of the packaging and the expiry date before each procedure and keep the reference and batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply contracts or validation of equivalences for tenders, contact our technical-commercial team.