Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament suture of polyglycolic acid (PGA) from the Prime range, factory reference P112HR3030 (SKU AMP112HR3030). It is the professional choice for general surgery departments and procedures requiring secure, manageable closure with controlled reabsorption. It combines a ½ circle needle with cylindrical body and 30 mm taperpoint conical tip (HR30), a 75 cm fluted violet thread in USP 3/0 gauge and a B2B presentation in a box of 12 units, designed for hospital supply, purchasing centres and tenders. A synthetic, sterile, single-use medical device with an excellent quality-price ratio for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the surface of the thread, reduces friction when passing through tissues, improves sliding and guarantees firm, secure knot tying even in fine-to-medium working gauges such as USP 3/0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed between 60 and 90 days: the thread maintains tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own strength. The HR30 ½ circle needle with cylindrical body and taperpoint conical tip penetrates by separating the fibres without a cutting effect, making it especially atraumatic for soft and friable tissues, ligatures and tissue approximation in general surgery. The violet colour of the thread ensures optimal visibility over the surgical field. Product sterilised by ethylene oxide, single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P112HR3030
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP112HR3030 |
| Factory reference | P112HR3030 (Prime range) |
| Thread material | 100% polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread colour | Violet (grooved); colourless available on request |
| Thread length | 75 cm (1 needle per suture) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Needle tip | Conical taperpoint, atraumatic |
| Needle size | HR 30 (30 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most established medium-duration absorbable braided multifilament on the market and shares its absorption profile (60–90 days), coated braided structure and clinical behaviour with the homologous families in the sector. There is no manufacturer-validated equivalence table cross-referencing this specific reference (100% PGA, HR30 needle with 30 mm conical tip, USP 3/0, violet, 75 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and must not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (braided coated polyglactin 910, violet) | J316H – USP 3/0, SH needle 26 mm, ½ circle, conical point, 70 cm | Comparable by category (not interchangeable 1:1) | Code verified in Ethicon’s official catalogue and authorised distribution: USP 3/0 gauge, ½ circle curvature, conical needle and violet colour match. They differ: polymer (polyglactin 910 versus 100% PGA), needle size (SH 26 mm versus HR30 30 mm), absorption profile (56–72 days versus 60–90 days), thread length (70 cm versus 75 cm) and presentation (box of 36 units versus 12 units). |
Homologous ranges in the medium-absorption braided PGA segment include Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH) and Atramat (Resorba), as well as the polyglactin 910 lines Coated VICRYL® / VICRYL® Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Assucryl 910 (Assut Sutures), comparable by category, material and absorption profile; for the exact combination USP 3/0 / HR 30 mm conical-tip needle / 75 cm in violet, their specific codes must be confirmed with the manufacturer before any substitution, verifying material, gauge, curvature, needle type and size, thread length, colour and attachment. This geometry (HR30, USP 3/0, 75 cm) is interchangeable with complete safety only within Cahnos’s own Prime system. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
USP 3/0 gauge (metric 2) is one of the most in-demand in general surgery: it is indicated for subcutaneous tissue, approximation of soft tissues, superficial fascia and ligation of fine-to-medium calibre vessels, with reliable healing support during the first 2–3 weeks. The HR30 ½ circle needle with taperpoint conical tip is atraumatic and ideal for soft and delicate tissues; if you need to penetrate firmer, denser tissues (skin, fascia, aponeurosis), consider the reverse cutting (HS) or trocar (HRT) points available in the same range, and if you prefer maximum atraumaticity, the blunt point (HRN).
| Variant / Reference | Description |
|---|---|
| AMP112HR3030 (P112HR3030) | PGA Prime – HR30 conical point – USP 3/0 violet – 75 cm (this product) |
| AM112HR3030 | Standard PGA – HR30 conical point – USP 3/0 violet – 75 cm (economical alternative, same geometry) |
| AMP112HR3020 | PGA Prime – HR30 conical point – USP 2/0 violet – 75 cm (larger gauge) |
| AMP112HR3010H | PGA Prime Heavy – HR30 conical point – USP 0 violet – 75 cm (thick gauge and reinforced needle) |
| AM112HRN3130 | PGA – HRN31 blunt point – USP 3/0 violet – 75 cm (atraumatic blunt point) |
| P1L12HR3030 | PGLA polyglactin 910 Prime – HR30 conical point – USP 3/0 violet – 75 cm (absorption 56–72 days) |
| AM312HR3030 | PGCL monofilament – HR30 conical point – USP 3/0 violet – 75 cm (absorption 90–120 days) |
The violet colour offers maximum visibility in the surgical field; if aesthetic discretion is required in superficial areas, request the same configuration in undyed thread. If longer strength retention is needed (180–210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference P112HR3030 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews