Absorbable Multifilament PGA 100% Polyglycolic Acid Suture | ½ Circle Cylindrical Taperpoint Conical Point Needle HR 48 mm | USP Gauge 2/0 (Metric 3) | Violet Thread 75 cm | Ref. AM112HR4820 | Box of 12 units

Original price was: 39,95 €.Current price is: 33,35 €.

Absorbable multifilament suture of 100% polyglycolic acid (PGA) mounted with a ½ circle needle, cylindrical body and Taperpoint conical point of 48 mm (HR 48), USP gauge 2/0 (metric 3) and 75 cm violet fluted thread. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Coated with polycaprolactone and calcium stearate for smooth passage, low memory and a firm, secure knot. Sterile by ethylene oxide, single-use and minimal tissue reaction. Ideal for tissue approximation, ligatures and general surgery. Reference AM112HR4820: price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112HR4820

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture, reference AM112HR4820, is the reference surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres that need a high-performance synthetic absorbable thread with an excellent quality-price ratio. This presentation combines a ½ circle needle with cylindrical body and taper point (Taperpoint) of 48 mm (HR 48), USP gauge 2/0 and 75 cm violet braided thread.

Each unit is supplied sterile, in an individual pouch with batch traceability and ready for immediate use, with the guarantee of professional distribution from Cahnos. Indicated for the approximation of soft tissues, ligatures and general surgery, where precision, handling and totally predictable absorption during the first weeks of healing are required.

2. Technical explanation of the product and procedure

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a braided finish and coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, reduces the sawing effect, offers very smooth handling, low memory and a firm and secure knot tie, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, an ideal profile for tissues requiring support for 2 to 4 weeks of healing.

The ½ circle needle with cylindrical body and taper point (Taperpoint) penetrates by separating the fibres without cutting them, which minimises trauma to soft and friable tissues; the violet colouration guarantees optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and not resterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AM112HR4820

Characteristic Specification
Reference (SKU) AM112HR4820 (factory ref. 112HR4820)
Thread material 100% polyglycolic acid (PGA), synthetic absorbable
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2/0 (metric 3 / EP 3); approx. diameter 0.30–0.349 mm
Thread colour Violet (also available colourless)
Thread length 75 cm (1 needle per suture)
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Conical (Taperpoint), atraumatic
Needle size 48 mm (HR 48)
Absorption mechanism Hydrolysis
Absorption period 60–90 days
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Regulatory standard Conforms to USP / EP Pharmacopoeia for synthetic absorbable sutures

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Total absorption 60–90 days, by hydrolysis

Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tie. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 (this product) 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2 5 0.50 – 0.599 mm

4. Equivalences and Cross-References

The medium-absorption (60–90 days) braided and coated multifilament polyglycolic acid (PGA) belongs to the most widespread classic family of synthetic absorbables on the market. By polymer composition (PGA homopolymer), braided structure, coating of polycaprolactone and calcium stearate, absorption profile by hydrolysis and tension retention, this reference is comparable at category level (not interchangeable 1:1) with the homologous lines of the main international manufacturers: Ethicon (Johnson & Johnson) with Coated VICRYL (coated braided polyglactin 910, violet; differs in copolymeric material PGLA 90/10 and absorption window 56–72 days), B. Braun with Safil (violet braided PGLA), Medtronic/Covidien with Polysorb, SMI with Surgicryl® PGA (PGA homopolymer, the closest composition, which includes in its catalogue the combination HR 48 / USP 2/0 / 75 cm in violet), DemeTECH with DemeSORB® PGA and the historical Dexon® series (Medtronic).

There is no equivalence table validated by the manufacturer that cross-references this specific reference (PGA multifilament, ½ circle taper point needle HR 48 mm, USP gauge 2/0, 75 cm violet thread, ref. 112HR4820) with closed codes from other commercial houses. Before replacing this reference in a specification or tender, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (taper/Taperpoint), thread length (75 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference. There is no equivalence table validated by the manufacturer; consult with the technical department before use in a tender.

5. Selection tips and variants of interest

USP gauge 2/0 (metric 3) offers an excellent balance between strength and delicacy: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and general surgery procedures, with predictable absorption during a healing period of 2 to 4 weeks. The taper point (HR) separates the fibres without cutting them and is ideal for soft tissues; if the tissue is very friable, the most atraumatic option is the blunt point (HRN), while for firm and dense tissues the trocar point (HRT) or the reverse cutting triangular point (HS) is recommended.

Within the Cahnos catalogue, the PGA family offers variants of this same HR 48 needle configuration:

Reference (SKU) Variant of interest
AMP112HR4820 PGA Prime quality, same exact configuration (HR 48, USP 2/0, violet, 75 cm)
AM112HR4810 PGA USP 0, same needle HR 48 mm, violet, 75 cm (larger gauge)
AM112HR4520 PGA USP 2/0, needle HR 45 mm, violet, 75 cm (smaller radius)
AM112HR4020 PGA USP 2/0, needle HR 40 mm, violet, 70/75 cm (more limited access)
1L12HR4820 Polyglactin 910 (PGLA) USP 2/0, needle HR 48 mm, violet, 75 cm (absorption 56–72 days)

If the protocol requires longer wound support, consider the polydioxanone (PDO) family (absorption 180–210 days); if a shorter resorption profile is required, consider the rapid-absorption range. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight and below 30 °C. For special B2B volume conditions, hospital supply contracts or equivalence validation for tendering, contact our technical-commercial team.

Additional information

Material

100% synthetic absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

USP size

2/0 (metric 3)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint)

Needle size

48 mm (HR 48)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

HR 48

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)