Description
1. Commercial Introduction
The Prime Heavy PGA Multifilament Absorbable Suture, reference AMP113HRN3610H, is the surgical closure solution your centre needs for general surgery procedures, tissue approximation and ligatures that require controlled reabsorption, excellent handling and impeccable knot security. It combines a ½ circle cylindrical-body needle with an atraumatic blunt point of 36 mm (HRN36) with a braided thread of 100% polyglycolic acid (PGA), USP 0, violet grooved colour and 90 cm length.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos for hospitals, clinics, operating theatres and purchasing centres. Presented in B2B format in a box of 12 units with a minimum order of 30 boxes, it offers an outstanding price-quality ratio for the continuous supply of surgical material.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a grooved finish, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with minimal tissue reaction.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, completed within 60 to 90 days. The thread maintains the necessary support during the first 2 to 4 weeks of healing, while the tissue recovers its own strength. The HRN36 needle features a ½ circle curvature with a cylindrical body and blunt point: a rounded point that separates tissue fibres without cutting them, ideal for soft and friable tissues. The Heavy version provides greater needle rigidity for fields with more resistant tissues, maintaining an atraumatic passage. The violet colour guarantees optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and non-re-sterilisable.
3. Technical Specifications
3.1. General characteristics of reference AMP113HRN3610H
| Characteristic | Specification |
| Reference (SKU) | AMP113HRN3610H |
| Range / Quality | Premisut – Prime Heavy |
| Material | 100 % Polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 0 (metric 3.5), conforming to USP/EP Pharmacopoeia |
| Thread colour | Violet grooved |
| Thread length | 90 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Blunt point (atraumatic) |
| Needle size | HRN 36 mm (Heavy version), 1 needle per thread |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units; minimum order of 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Braided polyglycolic acid (PGA) with medium absorption (60-90 days) is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. There is no official equivalence table validated by the manufacturer for a 1:1 cross-reference with the exact configuration of this reference (HRN 36 mm blunt point needle, USP 0, 90 cm violet thread); therefore, the codes cited below correspond to catalogue comparisons verified against the official Ethicon website and authorised distribution, and are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet, USP 0, 90 cm, CT-1 needle with conical point (taper point), ½ circle, 36 mm | J346H | Comparable by category (not interchangeable 1:1) | Confirmed in Ethicon catalogue and authorised distribution: USP 0, violet colour, 90 cm length, ½ circle shape and 36 mm needle size with atraumatic point match; the polymer (polyglactin 910 vs 100% PGA), the point profile (conical vs blunt) and the absorption period (56-72 days vs 60-90 days) differ. |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® Plus Antibacterial – polyglactin 910 braided with triclosan, violet, USP 0, 90 cm, 36 mm tapercut needle, ½ circle | W9467 | Comparable by category (not interchangeable 1:1) | Confirmed in authorised distribution: USP 0, violet colour, 90 cm length, ½ circle shape and 36 mm needle size match; the polymer (polyglactin 910 with triclosan vs 100% PGA), the point (trocar/tapercut vs atraumatic blunt), the presentation (box of 36 units vs 12 units) and the absorption (56-72 days vs 60-90 days) differ. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
As homologous families on the market, to be verified reference by reference in their official datasheet before substitution, the following lines are cited: 100% braided coated PGA —Safil (B. Braun), Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH)— and polyglactin 910 —Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 0, 36 mm needle size in ½ circle, blunt point, 90 cm thread length and violet colour. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
Within the Cahnos catalogue, the closest configuration is reference P1L13HRN3610H (PGLA Prime Heavy, same HRN36 blunt point needle, USP 0, violet, 90 cm), which differs only in the base polymer and the absorption period (56-72 days); the same needle in standard quality corresponds to AM113HRN3610H.
5. Selection tips and variants of interest
USP 0 (metric 3.5) is indicated for tissues under moderate-medium tension: fascia, aponeurosis, abdominal wall, subcutaneous tissue and ligatures of medium-calibre vessels. The blunt point needle (HRN) is the atraumatic choice par excellence for soft and friable tissues; if a point that penetrates firmer tissues is preferred, conical point (HR) or trocar (HRT) versions are available in 36 mm in the same range.
| Reference | Recommended variant |
| AMP113HRN3610H | PGA Prime Heavy USP 0, HRN36 blunt point needle, violet, 90 cm (current product) |
| AMP113HRN3601H | PGA Prime Heavy USP 1, same HRN36 needle, violet, 90 cm (larger calibre) |
| AMP113HRN4010H | PGA Prime Heavy USP 0, HRN40 blunt point needle, violet, 90 cm (larger radius for deep fields) |
| AMP112HRN3610 | PGA Prime USP 0, same HRN36 needle, violet, 75 cm (shorter thread) |
| AMP113HRT3610 | PGA Prime USP 0, HRT36 trocar point needle, violet, 90 cm (firmer tissues) |
| P1L13HRN3610H | PGLA Prime Heavy USP 0, same HRN36 needle, violet, 90 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. If you require longer force retention (180-210 days), consider the polydioxanone (PDO) family. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, and keep the reference alongside the batch number for traceability in the operating theatre. For B2B volume conditions or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.