Description
1. Product Presentation
The absorbable multifilament PGA suture from the Prime range is the surgical closure solution your centre needs for general surgery procedures that require controlled absorption, excellent handling and impeccable knot security. It combines a ½ circle needle with a triangular reverse cutting point of 36 mm (HS36) with a braided thread of 100% polyglycolic acid (PGA) in USP 0 gauge, violet, grooved and 70 cm in length.
Presented in B2B format in a box of 12 units with a minimum order of 30 boxes, it offers an outstanding price-quality ratio for hospitals, clinics, distributors and purchasing centres for surgical supplies. The Prime range provides a high-performance finish with fully predictable absorption and minimal tissue reaction.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer that is presented in a braided multifilament structure, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding and facilitates firm, secure knotting, with minimal tissue reaction.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, completed between 60 and 90 days. Tensile strength retention maintains the necessary support during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 and 40% at 4), while the tissue recovers its own strength.
The HS36 needle has a ½ circle curvature with a triangular body and a reverse cutting point: the cutting edge is oriented towards the inside of the arc, which facilitates penetration into firm, non-distensible tissues (aponeurosis, fascia, skin, abdominal wall) without enlarging the puncture bed. Product sterile by ethylene oxide, single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P118HS3610
| Characteristic | Specification |
| Factory reference | P118HS3610 |
| Reference Cahnos (SKU) | AMP118HS3610 |
| Thread material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Quality | Prime |
| Gauge / size | USP 0 (metric 3.5), conforming to USP/EP Pharmacopoeia |
| Thread colour | Fluted violet (colourless version available in the family) |
| Thread length | 70 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle tip | Triangular reverse cutting (reverse cutting) |
| Needle size | HS 36 mm, 1 needle per suture |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units; minimum order of 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis |
3.3. Reference decoding
Official reference P118HS3610: 118 (70 cm thread) + HS36 (½ circle needle with reverse cutting triangular point of 36 mm) + 10 (USP 0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. There is no equivalence table validated by the manufacturer that cross-references this reference with other commercial brands; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL / VICRYL Plus (braided polyglactin 910, violet) | Not published (verify exact configuration) | Comparable by category (not interchangeable 1:1) | They match in multifilament structure, USP 0 gauge and ½ circle cutting point needle; they differ in polymer (polyglactin 910, absorption 56-72 days, versus PGA of 60-90 days for this reference), braid coating and strength retention at 4 weeks. Verify absorption profile before substituting. |
| B. Braun (Aesculap) | Safil (pure braided polyglycolic acid, violet) | Not published (verify exact configuration) | Comparable by category (not interchangeable 1:1) | Same raw material (pure PGA) and absorbable braided structure, with complete absorption from 60 to 90 days; they differ in coating, exact retention profile and needle geometry/code. Check USP 0 gauge, HS36 size and 1-needle assembly in the official data sheet. |
| Medtronic / Covidien | Dexon / Polysorb (absorbable braided range) | Not published (verify exact configuration) | Comparable by category (not interchangeable 1:1) | Dexon is pure braided PGA and Polysorb is polyglactin 910; absorption and retention profiles are similar but not identical. Validate property by property (material, gauge, HS36 needle and length) before substitution. |
| SMI / Assut | Surgicryl / Assucryl (polyglycolic acid / polyglactin 910) | Not published (verify exact configuration) | Comparable by category (not interchangeable 1:1) | Homologous families of the PGA/PGLA segment; check exact material, USP 0 gauge, needle size and needle assembly in their technical data sheets. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference; no unverified cross-reference codes are published.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) is indicated for tissues requiring medium-high initial strength: aponeurosis, fascia, muscle planes and moderate tension closures. The ½ circle needle with reverse cutting triangular point (HS36) is the appropriate choice for firm, non-distensible tissues; if you need to pass through soft tissues with minimal injury, consider conical points (HR/taperpoint) or trocar points from the same PGA family.
| Variant (SKU Cahnos) | Description |
| AMP118HS3610 (P118HS3610) | PGA Prime – HS36 reverse cutting – USP 0 violet – 70 cm (this product) |
| AMP113HS3601 | PGA Prime – HS36 reverse cutting – USP 1 violet – 90 cm (larger gauge and length) |
| AMP113HS3610 | PGA Prime – HS36 reverse cutting – USP 0 violet – 90 cm (same needle, longer thread) |
| AMP112DS3602 | PGA Prime – DS36 reverse cutting 3/8 – USP 2 violet – 75 cm (3/8 needle for confined spaces) |
| AMP113HRT3610 | PGA Prime – HRT36 trocar point – USP 0 violet – 90 cm (firm tissues with cylindrical body) |
If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. Sterile single-use product: check the integrity of the pouch and the expiry date before each procedure and keep reference P118HS3610 together with the batch number for traceability in the operating theatre. For B2B volume conditions or equivalences from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews