Absorbable Multifilament PGA Suture 1/2 Circle Reverse Cutting Triangular Point HS 48 mm | USP 2 Calibre | Violet Thread 90 cm | Ref. P113HS4802

Original price was: 46,61 €.Current price is: 29,75 €.

Absorbable multifilament PGA Prime suture of 100 % polyglycolic acid, with a ½ circle reverse cutting triangular needle of 48 mm (HS48), USP 2 calibre and 90 cm violet fluted thread. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Ref. P113HS4802 (SKU AMP113HS4802) in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP113HS4802

Description

1. Introduction

The absorbable multifilament PGA Prime suture from the Cahnos range is the reference choice in the operating theatre for the professional seeking a synthetic thread with reliable, predictable, high-quality performance in the approximation of soft tissues, ligatures and general surgery. Its ½ circle reverse cutting triangular needle of 48 mm (HS48) ensures firm and precise penetration even in dense tissues, while the 90 cm violet fluted thread offers optimal visibility of the surgical field and excellent handling in every stitch.

Manufactured under strict quality standards for the B2B channel, it combines minimal tissue reaction, excellent tensile strength and optimal knot security, ensuring consistency and clinical results in every procedure. Commercial presentation in a box of 12 units, ideal for the continuous supply of hospitals, clinics and purchasing centres.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying, even in larger diameter calibres such as USP 2 (metric 5). The coating of polycaprolactone and calcium stearate improves sliding and reduces friction.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days. This profile makes it suitable for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point (Reverse Cutting) of 48 mm penetrates firm and dense tissues with controlled trauma, minimising damage at the entry point.

3. Technical Specifications

3.1. General characteristics of reference P113HS4802

Characteristic Specification
Reference (SKU) AMP113HS4802 / P113HS4802
Material 100 % Absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2 (metric 5)
Thread colour Violet grooved
Thread length 90 cm
Needle shape ½ circle
Needle tip Triangular reverse cutting (Reverse Cutting)
Needle size 48 mm (HS 48 Prime)
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide (EO), single-use / sterile
Tissue reaction Minimal
Presentation Box of 12 units

3.2. Tensile strength retention profile

Period Remaining tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 40% of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and general surgery.

4. Equivalences and Cross-References

This multifilament polyglycolic acid (PGA) suture belongs to the family of synthetic absorbable braided sutures of medium absorption and is clinically positioned alongside the reference polyglactin 910 sutures of the international market (Vicryl, Safil, Polysorb, Surgicryl). All share a braided structure, violet colour, ethylene oxide sterilisation and absorption by hydrolysis in the range of 56-90 days; the main difference is the composition (PGA homopolymer versus 90/10 glycolide-lactide copolymer), so the comparison is at category level and not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson) VICRYL Plus (braided polyglactin 910, violet, 90 cm, ½ circle reverse cutting needle 48 mm) VCP1059H Comparable by category (not interchangeable 1:1) Composition 90/10 glycolide/L-lactide copolymer versus PGA homopolymer; absorption 56-70 days; same HS48 mm needle, USP 2, violet, 90 cm. Verify the manufacturer’s technical data sheet before substituting.

Other commercial houses with homologous families of absorbable braided suture (B. Braun with its Safil line of polyglactin 910, Medtronic with the Polysorb range and SMI with Surgicryl) offer products of the same category, but there is no equivalence table validated by the manufacturer for this specific reference; consult the technical department before use in tendering.

Within the Cahnos catalogue, its direct equivalent in structure and needle is reference P1L13HS4802 (PGLA Prime, HS 48 mm triangular needle, USP 2, violet, 90 cm), with the alternative in standard quality 1L13HS4802.

5. Selection tips and variants of interest

To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the calibre according to the anatomical area. USP 2 calibre (metric 5) is indicated for tissues that require greater initial resistance: deep planes, fascia, aponeurosis, high-tension closures and ligatures.

  • AMP113HS4802: PGA Prime USP 2, HS 48 mm triangular needle, violet, 90 cm (current product).
  • AMP113HS4801: PGA Prime USP 1, same HS 48 mm needle, violet, 90 cm (smaller calibre for moderate tension).
  • AMP113HS4002: PGA Prime USP 2, HS 40 mm needle, violet, 90 cm (shorter needle).
  • AMP113HR4802: PGA Prime USP 2, HR 48 mm cylindrical needle, violet, 90 cm (atraumatic conical point for soft tissues).
  • P1L13HS4802: PGLA Prime USP 2, HS 48 mm triangular needle, violet, 90 cm (alternative in polyglactin 910).

For longer force retention needs (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units. As it is a sterile single-use product, check the integrity of the packaging before each procedure. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglycolic acid (PGA) 100 %

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5)

Needle tip

Triangular reverse cutting (Reverse Cutting)

Needle size

48 mm (HS 48)

Sterilisation

Ethylene oxide, single-use

Presentation

Box of 12 units

Manufacturer reference

P113HS4802

Medida de aguja

HS 48

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)