We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture USP 2 Gauge | 1/2 Circle Needle Reverse Cutting Triangular Point HS 40 mm | Violet 90 cm | Ref. P113HS4002 – Box of 12 units

Original price was: 46,61 €.Current price is: 28,55 €.

Absorbable multifilament polyglycolic acid (PGA) suture of Prime quality, USP 2 gauge, with a ½ circle needle with a 40 mm reverse cutting triangular point (HS 40) and a 90 cm fluted violet thread. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security, indicated for high-tension tissue approximation, ligatures and general surgery. Reference P113HS4002, presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP113HS4002

Description

1. Introduction

The Absorbable Multifilament PGA Prime Suture in USP 2 gauge is the reference choice in the operating theatre for professionals who need a high-performance synthetic absorbable thread for the approximation of firm tissues, deep planes and high-tension ligatures. Its ½ circle needle with a 40 mm (HS 40) reverse cutting triangular point penetrates dense tissues with controlled trauma, while the 90 cm fluted violet thread ensures optimal visibility in the surgical field and exceptional handling with every stitch. Commercial presentation in a box of 12 units, designed for the continuous supply of hospitals, clinics and purchasing centres.

2. Technical explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish. Its coating of polycaprolactone and calcium stearate improves the sliding of the thread through tissue, reduces friction and facilitates firm, secure knot tying, even in large-diameter gauges such as USP 2 (metric 5).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The ½ circle needle with a 40 mm reverse cutting triangular body and point is designed to penetrate firm, consistent tissues without tearing, making it particularly suitable for closures of fascia, aponeurosis, muscular planes and high-tension ligatures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P113HS4002

Characteristic Specification
Material 100% synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2 (metric 5)
Thread colour Violet grooved
Needle shape ½ circle
Tip type Reverse cutting triangular (body and point)
Needle size 40 mm (HS 40)
Thread length 90 cm
Absorption mechanism Hydrolysis (60-90 days)
Sterilisation Ethylene oxide; single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Reference (SKU) P113HS4002 (AMP113HS4002)

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Complete absorption 60-90 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) is the most widely used medium-duration braided multifilament absorbable on the market. This reference shares the absorption profile (60-90 days), coated braided structure, USP 2 gauge, ½ circle reverse cutting HS 40 mm needle and 90 cm length with the main homologous families of medium-absorption braided absorbable suture. Comparison with polymers other than PGA homopolymer is made at category level: Ethicon (Johnson & Johnson) with its violet braided polyglactin 910 Vicryl line, B. Braun with the Safil line of polyglycolic acid (absorption profile 60-90 days very similar to PGA homopolymer), Medtronic with the Polysorb range and SMI with Surgicryl PGA. For this exact configuration (USP 2 / HS 40 mm needle / 90 cm) no reference code from other manufacturers confirmed against an official source is available; there is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

Within the Cahnos catalogue, the same configuration in polyglactin 910 (PGLA) is supplied as P1L13HS4002 in Prime quality and 1L13HS4002 in the standard range; within the PGA family itself, the gauge variants of the same HS 40 mm needle are AMP113HS4001 (USP 1) and AMP113HS4010 (USP 0).

5. Selection tips and variants of interest

USP 2 gauge (metric 5) is indicated for tissues requiring high initial strength: deep planes, fascia, aponeurosis, high-tension closures and large-calibre ligatures. The reverse cutting triangular point (HS) is recommended for passing through firm, dense tissues without tearing (skin, fascia); if the tissue is soft or friable, consider the conical point variant (HR).

Reference Variant of interest
AMP113HS4002 PGA Prime USP 2, HS 40 mm triangular needle, violet, 90 cm (current product)
AMP113HS4001 PGA Prime USP 1, same HS 40 mm needle (smaller gauge)
AMP113HS4010 PGA Prime USP 0, same HS 40 mm needle (tissues with less tension)
AM113HS4002 PGA USP 2, same HS 40 mm needle, violet, 90 cm (standard range)
AMP113HS4810 PGA Prime USP 0, HS 48 mm triangular needle (longer needle)
P1L13HS4002 PGLA Prime USP 2, HS 40 mm triangular needle, violet, 90 cm (alternative polymer)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglycolic acid (PGA) 100 % synthetic absorbable

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5)

Colour

Violet grooved

Tip type

Reverse cutting triangular (body and point)

Needle size

40 mm (HS 40)

Absorption mechanism

Hydrolysis (60-90 days)

Strength retention

75 % at 2 weeks, 50 % at 3 weeks, 40 % at 4 weeks

Sterilisation

Ethylene oxide (single-use)

Presentation

Box of 12 units

Manufacturer reference

P113HS4002

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

HS 40

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture USP 2 Gauge | 1/2 Circle Needle Reverse Cutting Triangular Point HS 40 mm | Violet 90 cm | Ref. P113HS4002 – Box of 12 units”

Your email address will not be published. Required fields are marked *